Microwave to near-infrared conversion with a millimeter-scale wireless laser for activating molecular transducers.
Abstract
Light-activated molecular transducers enable precise manipulation of biological processes and are thus powerful tools for studying or treating disease. Their use in vivo, however, is currently limited by the low penetration of light through biological tissue. While electromagnetic fields at microwave frequencies can penetrate thick tissue, they do not provide direct control over molecular transducers. Here, we describe a miniaturized, wirelessly powered laser capable of delivering high intensity near-infrared light in tissue. The device is about 2.5 mm in the largest dimension, weighs less than 30 mg, and can be wirelessly powered through >1 cm of tissue. This device could be used in emerging bioelectronics-based treatments that combine the precision of light with the penetration depth of microwaves.
AI evidence extraction
Main findings
The authors describe a miniaturized wirelessly powered laser (~2.5 mm largest dimension, <30 mg) that can deliver high-intensity near-infrared light in tissue and can be wirelessly powered through more than 1 cm of tissue.
Outcomes measured
- Wireless powering through tissue
- Near-infrared light delivery in tissue
- Device miniaturization (size/weight)
Limitations
- No microwave frequency, power, or SAR parameters reported in the abstract
- No biological/health outcomes reported; focus is on device capability
- No sample size or experimental details provided in the abstract
View raw extracted JSON
{
"study_type": "engineering",
"exposure": {
"band": "microwave",
"source": "wireless power (miniaturized implantable laser)",
"frequency_mhz": null,
"sar_wkg": null,
"duration": null
},
"population": null,
"sample_size": null,
"outcomes": [
"Wireless powering through tissue",
"Near-infrared light delivery in tissue",
"Device miniaturization (size/weight)"
],
"main_findings": "The authors describe a miniaturized wirelessly powered laser (~2.5 mm largest dimension, <30 mg) that can deliver high-intensity near-infrared light in tissue and can be wirelessly powered through more than 1 cm of tissue.",
"effect_direction": "unclear",
"limitations": [
"No microwave frequency, power, or SAR parameters reported in the abstract",
"No biological/health outcomes reported; focus is on device capability",
"No sample size or experimental details provided in the abstract"
],
"evidence_strength": "insufficient",
"confidence": 0.7399999999999999911182158029987476766109466552734375,
"peer_reviewed_likely": "yes",
"keywords": [
"microwave",
"wireless power",
"near-infrared",
"laser",
"implantable device",
"molecular transducers",
"bioelectronics",
"tissue penetration"
],
"suggested_hubs": []
}
AI can be wrong. Always verify against the paper.