The use of a standard radiofrequency energy delivery system to facilitate transseptal puncture.

PAPER pubmed Journal of cardiovascular electrophysiology 2009 Other Effect: unclear Evidence: Insufficient

Abstract

Transseptal puncture is a standard means of catheter access to the left atrium via the venous system, but carries a risk of cardiac perforation. Stretching and increased force to traverse the septum are required with elastic, aneurysmal, or thickened interatrial tissue. We describe a technique that facilitates transseptal puncture by applying brief pulses of radiofrequency energy from a standard electrosurgical cautery generator through the needle tip.

AI evidence extraction

At a glance
Study type
Other
Effect direction
unclear
Population
β€”
Sample size
β€”
Exposure
electrosurgical cautery generator (radiofrequency energy applied via transseptal needle tip) Β· brief pulses
Evidence strength
Insufficient
Confidence: 62% Β· Peer-reviewed: yes

Main findings

The abstract describes a technique to facilitate transseptal puncture by applying brief pulses of radiofrequency energy from a standard electrosurgical cautery generator through the needle tip.

Outcomes measured

  • Facilitation of transseptal puncture
  • Risk of cardiac perforation (context)

Limitations

  • No study design details provided in the abstract (e.g., controlled comparison, endpoints, follow-up).
  • No sample size or participant characteristics reported.
  • No quantitative safety or efficacy outcomes reported.

Suggested hubs

  • engineering (0.55)
    Use of radiofrequency energy delivery system as a procedural technique in electrophysiology.
View raw extracted JSON
{
    "study_type": "other",
    "exposure": {
        "band": null,
        "source": "electrosurgical cautery generator (radiofrequency energy applied via transseptal needle tip)",
        "frequency_mhz": null,
        "sar_wkg": null,
        "duration": "brief pulses"
    },
    "population": null,
    "sample_size": null,
    "outcomes": [
        "Facilitation of transseptal puncture",
        "Risk of cardiac perforation (context)"
    ],
    "main_findings": "The abstract describes a technique to facilitate transseptal puncture by applying brief pulses of radiofrequency energy from a standard electrosurgical cautery generator through the needle tip.",
    "effect_direction": "unclear",
    "limitations": [
        "No study design details provided in the abstract (e.g., controlled comparison, endpoints, follow-up).",
        "No sample size or participant characteristics reported.",
        "No quantitative safety or efficacy outcomes reported."
    ],
    "evidence_strength": "insufficient",
    "confidence": 0.61999999999999999555910790149937383830547332763671875,
    "peer_reviewed_likely": "yes",
    "keywords": [
        "transseptal puncture",
        "radiofrequency energy",
        "electrosurgery",
        "cautery generator",
        "catheter access",
        "left atrium"
    ],
    "suggested_hubs": [
        {
            "slug": "engineering",
            "weight": 0.5500000000000000444089209850062616169452667236328125,
            "reason": "Use of radiofrequency energy delivery system as a procedural technique in electrophysiology."
        }
    ]
}

AI can be wrong. Always verify against the paper.

AI-extracted fields are generated from the abstract/metadata and may be incomplete or incorrect. This content is for informational purposes only and is not medical advice.

Comments

Log in to comment.

No comments yet.