Share
𝕏 Facebook LinkedIn

The Effectiveness of a Conductive Patch and a Conductive Bed Pad in Reducing Induced Human Body Voltage Via the Application of Earth Ground

PAPER manual European Biology and Bioelectromagnetics 2005 Exposure assessment Effect: benefit Evidence: Very low

Abstract

Voltage induced on a human body by capacitive coupling to the external environment was measured using a high-impedance measurement head. The body was then earth grounded by means of a Conductive Patch and a Conductive Bed Pad. Each method reduced the coupled 60Hz mains voltage by a factor of at least 70. This result, along with the measurement of the voltage drop across an in-line resistance in the Conductive Patch provided evidence of a simplified electrical network model of the human body.

AI evidence extraction

At a glance
Study type
Exposure assessment
Effect direction
benefit
Population
human body (unspecified participants)
Sample size
—
Exposure
ELF mains electricity / capacitive coupling to external environment
Evidence strength
Very low
Confidence: 66% · Peer-reviewed: unknown

Main findings

Voltage induced on a human body via capacitive coupling was measured, then the body was earth grounded using a conductive patch and a conductive bed pad. Each grounding method reduced coupled 60 Hz mains voltage by a factor of at least 70. A measured voltage drop across an in-line resistance in the conductive patch was reported as evidence supporting a simplified electrical network model of the human body.

Outcomes measured

  • Induced human body voltage (60 Hz mains)
  • Voltage drop across in-line resistance (conductive patch)

Limitations

  • Sample size and participant characteristics not stated in abstract
  • Study design details (controls, blinding, measurement conditions) not described in abstract
  • Only 60 Hz mains voltage reduction reported; broader exposure conditions not addressed

Suggested hubs

  • occupational-exposure (0.2)
    Study concerns 60 Hz mains-related induced body voltage, which can be relevant to occupational/indoor electrical environments, though no workplace setting is specified.
View raw extracted JSON
{
    "study_type": "exposure_assessment",
    "exposure": {
        "band": "ELF",
        "source": "mains electricity / capacitive coupling to external environment",
        "frequency_mhz": null,
        "sar_wkg": null,
        "duration": null
    },
    "population": "human body (unspecified participants)",
    "sample_size": null,
    "outcomes": [
        "Induced human body voltage (60 Hz mains)",
        "Voltage drop across in-line resistance (conductive patch)"
    ],
    "main_findings": "Voltage induced on a human body via capacitive coupling was measured, then the body was earth grounded using a conductive patch and a conductive bed pad. Each grounding method reduced coupled 60 Hz mains voltage by a factor of at least 70. A measured voltage drop across an in-line resistance in the conductive patch was reported as evidence supporting a simplified electrical network model of the human body.",
    "effect_direction": "benefit",
    "limitations": [
        "Sample size and participant characteristics not stated in abstract",
        "Study design details (controls, blinding, measurement conditions) not described in abstract",
        "Only 60 Hz mains voltage reduction reported; broader exposure conditions not addressed"
    ],
    "evidence_strength": "very_low",
    "confidence": 0.66000000000000003108624468950438313186168670654296875,
    "peer_reviewed_likely": "unknown",
    "keywords": [
        "earthing",
        "grounding",
        "conductive patch",
        "conductive bed pad",
        "induced body voltage",
        "capacitive coupling",
        "60 Hz",
        "mains voltage",
        "ELF"
    ],
    "suggested_hubs": [
        {
            "slug": "occupational-exposure",
            "weight": 0.200000000000000011102230246251565404236316680908203125,
            "reason": "Study concerns 60 Hz mains-related induced body voltage, which can be relevant to occupational/indoor electrical environments, though no workplace setting is specified."
        }
    ]
}

AI can be wrong. Always verify against the paper.

AI-extracted fields are generated from the abstract/metadata and may be incomplete or incorrect. This content is for informational purposes only and is not medical advice.

Comments

Log in to comment.