Radiofrequency exposure levels in Amsterdam schools

PAPER manual 2017 Exposure assessment Effect: unclear Evidence: Low

Abstract

Radiofrequency exposure levels in Amsterdam schools van Wel L, Vermeulen R, van Eijsden M, Vrijkotte T, Kromhout H, Huss A. Radiofrequency exposure levels in Amsterdam schools. Bioelectromagnetics. 2017 Apr 25. doi: 10.1002/bem.22053. No Abstract ncbi.nlm.nih.gov This letter to the editor reports the results of RF exposure levels in 102 primary schools in Amsterdam. GSM base stations (900 + 1800 MHz downlink) provided the largest contribution to the total average RF power density (38.0%), followed by DECT cordless phones (27.3%) and GSM mobile devices (11.1%), Although WiFi contributed only 4.5% of the total average power density, the assessments were conducted after school so it was unlikely that any wireless laptops or tablets were being used at the time.

AI evidence extraction

At a glance
Study type
Exposure assessment
Effect direction
unclear
Population
Primary schools in Amsterdam (Netherlands)
Sample size
102
Exposure
RF school environment (GSM base stations, DECT cordless phones, GSM mobile devices, WiFi)
Evidence strength
Low
Confidence: 74% · Peer-reviewed: yes

Main findings

In measurements from 102 Amsterdam primary schools, GSM base stations (900 and 1800 MHz downlink) contributed the largest share of total average RF power density (38.0%), followed by DECT cordless phones (27.3%) and GSM mobile devices (11.1%). WiFi contributed 4.5% of the total average power density; measurements were conducted after school, when wireless laptops/tablets were unlikely to be in use.

Outcomes measured

  • RF power density (total average)
  • Source contributions to total average RF power density (GSM base stations 900/1800 MHz downlink, DECT, GSM mobile devices, WiFi)

Limitations

  • Reported as a letter to the editor with no abstract available
  • Assessments were conducted after school, so WiFi use during school hours may not be represented

Suggested hubs

  • school-wi-fi (0.86)
    RF exposure assessment conducted in primary schools; WiFi contribution discussed.
View raw extracted JSON
{
    "study_type": "exposure_assessment",
    "exposure": {
        "band": "RF",
        "source": "school environment (GSM base stations, DECT cordless phones, GSM mobile devices, WiFi)",
        "frequency_mhz": null,
        "sar_wkg": null,
        "duration": null
    },
    "population": "Primary schools in Amsterdam (Netherlands)",
    "sample_size": 102,
    "outcomes": [
        "RF power density (total average)",
        "Source contributions to total average RF power density (GSM base stations 900/1800 MHz downlink, DECT, GSM mobile devices, WiFi)"
    ],
    "main_findings": "In measurements from 102 Amsterdam primary schools, GSM base stations (900 and 1800 MHz downlink) contributed the largest share of total average RF power density (38.0%), followed by DECT cordless phones (27.3%) and GSM mobile devices (11.1%). WiFi contributed 4.5% of the total average power density; measurements were conducted after school, when wireless laptops/tablets were unlikely to be in use.",
    "effect_direction": "unclear",
    "limitations": [
        "Reported as a letter to the editor with no abstract available",
        "Assessments were conducted after school, so WiFi use during school hours may not be represented"
    ],
    "evidence_strength": "low",
    "confidence": 0.7399999999999999911182158029987476766109466552734375,
    "peer_reviewed_likely": "yes",
    "keywords": [
        "radiofrequency",
        "exposure assessment",
        "schools",
        "Amsterdam",
        "power density",
        "GSM",
        "base stations",
        "DECT",
        "WiFi"
    ],
    "suggested_hubs": [
        {
            "slug": "school-wi-fi",
            "weight": 0.85999999999999998667732370449812151491641998291015625,
            "reason": "RF exposure assessment conducted in primary schools; WiFi contribution discussed."
        }
    ]
}

AI can be wrong. Always verify against the paper.

AI-extracted fields are generated from the abstract/metadata and may be incomplete or incorrect. This content is for informational purposes only and is not medical advice.

Comments

Log in to comment.

No comments yet.