RF exposure assessment of baby surveillance devices in the frequency range 400 MHz-2.45 GHz

PAPER manual 2018 Exposure assessment Effect: no_effect Evidence: Low

Abstract

RF exposure assessment of baby surveillance devices in the frequency range 400 MHz-2.45 GHz Vermeeren G, Joseph W, Martens L. Radiofrequency exposure assessment of baby surveillance devices in the frequency range 400 MHz-2.45 GHz. Bioelectromagnetics. 2018 Apr;39(3):244-248. doi: 10.1002/bem.22113. No abstract Excerpts We investigated the exposure, in terms of both the peak spatial‐averaged specific absorption rate (SAR) in 10 g of tissue and the time-averaged root-mean-squared (RMS) electric (E) field, induced by baby monitors operating in a frequency range between 400 MHz and 2.45 GHz. We selected nine commercially available baby monitors ... Considering all investigated devices, the peak spatial SAR in 10 g ranged from 0.09 to 0.37 W/kg, which is 22.3- 5.4 times below the ICNIRP basic restriction. In summary, we measured the induced time-averaged root-mean-square electric field strength and the peak spatial-averaged specific absorption rate from the baby unit of nine commercially available devices and compared both with the ICNIRP guidelines. The communication technologies implemented in the baby monitors were: PMR446, continuous transmission at 864 MHz, DECT, and communication in the ISM band at 2450 MHz. The electric field was measured at a distance of 50 cm from the baby unit of the baby monitor. We measured the SAR in a flat phantom filled with head tissue simulating liquid and the baby unit touching the flat phantom. The maximum time-averaged root-mean-square electric field value closest to the ICNIRP reference level over all investigated devices was 1.51 V/m (for modern‐electronics DBS 3), which is 19.4 times below the ICNIRP reference level at 466 MHz. The peak spatial‐averaged SAR in 10 g of tissue was 0.37 W/kg in head simulating tissue (for Alecto-DBX-82), which is 5.4 times below the basic restriction of 2 W/kg as specified by ICNIRP. ncbi.nlm.nih.gov Note: The ICNIRP guidelines were designed to protect users only from short-term thermal effects.

AI evidence extraction

At a glance
Study type
Exposure assessment
Effect direction
no_effect
Population
—
Sample size
9
Exposure
RF baby monitor · 0.37 W/kg
Evidence strength
Low
Confidence: 74% · Peer-reviewed: yes

Main findings

Nine commercially available baby monitors (400 MHz–2.45 GHz; PMR446, 864 MHz continuous transmission, DECT, and 2450 MHz ISM) were assessed. Peak spatial-averaged SAR in 10 g ranged from 0.09 to 0.37 W/kg, reported as 22.3–5.4 times below the ICNIRP basic restriction; the maximum measured time-averaged RMS E-field at 50 cm was 1.51 V/m, reported as 19.4 times below the ICNIRP reference level at 466 MHz.

Outcomes measured

  • Peak spatial-averaged SAR in 10 g tissue (W/kg)
  • Time-averaged RMS electric field strength (V/m)
  • Comparison with ICNIRP basic restrictions/reference levels

Limitations

  • No abstract provided; information is from excerpts only
  • E-field measurements were taken at a single stated distance (50 cm) from the baby unit
  • SAR measurements used a flat phantom with head-tissue simulating liquid and the baby unit touching the phantom
  • Only nine commercially available devices were selected; selection criteria not described in provided text

Suggested hubs

  • who-icnirp (0.78)
    Study explicitly compares measured SAR and E-field values with ICNIRP basic restrictions/reference levels.
View raw extracted JSON
{
    "study_type": "exposure_assessment",
    "exposure": {
        "band": "RF",
        "source": "baby monitor",
        "frequency_mhz": null,
        "sar_wkg": 0.36999999999999999555910790149937383830547332763671875,
        "duration": null
    },
    "population": null,
    "sample_size": 9,
    "outcomes": [
        "Peak spatial-averaged SAR in 10 g tissue (W/kg)",
        "Time-averaged RMS electric field strength (V/m)",
        "Comparison with ICNIRP basic restrictions/reference levels"
    ],
    "main_findings": "Nine commercially available baby monitors (400 MHz–2.45 GHz; PMR446, 864 MHz continuous transmission, DECT, and 2450 MHz ISM) were assessed. Peak spatial-averaged SAR in 10 g ranged from 0.09 to 0.37 W/kg, reported as 22.3–5.4 times below the ICNIRP basic restriction; the maximum measured time-averaged RMS E-field at 50 cm was 1.51 V/m, reported as 19.4 times below the ICNIRP reference level at 466 MHz.",
    "effect_direction": "no_effect",
    "limitations": [
        "No abstract provided; information is from excerpts only",
        "E-field measurements were taken at a single stated distance (50 cm) from the baby unit",
        "SAR measurements used a flat phantom with head-tissue simulating liquid and the baby unit touching the phantom",
        "Only nine commercially available devices were selected; selection criteria not described in provided text"
    ],
    "evidence_strength": "low",
    "confidence": 0.7399999999999999911182158029987476766109466552734375,
    "peer_reviewed_likely": "yes",
    "keywords": [
        "baby monitor",
        "baby surveillance devices",
        "radiofrequency",
        "RF exposure",
        "SAR",
        "10 g SAR",
        "RMS electric field",
        "PMR446",
        "DECT",
        "ISM 2450 MHz",
        "ICNIRP"
    ],
    "suggested_hubs": [
        {
            "slug": "who-icnirp",
            "weight": 0.7800000000000000266453525910037569701671600341796875,
            "reason": "Study explicitly compares measured SAR and E-field values with ICNIRP basic restrictions/reference levels."
        }
    ]
}

AI can be wrong. Always verify against the paper.