Share
𝕏 Facebook LinkedIn

Statistical approach for human electromagnetic exposure assessment in future wireless ATTO-cell networks

PAPER manual 2019 Exposure assessment Effect: no_effect Evidence: Low

Abstract

Statistical approach for human electromagnetic exposure assessment in future wireless ATTO-cell networks Shikhantsov S, Thielens A, Vermeeren G, Demeester P, Martens L, Torfs G, Joseph W. Statistical approach for human electromagnetic exposure assessment in future wireless ATTO-cell networks. Radiat Prot Dosimetry. 2019 May 1;183(3):326-331. doi: 10.1093/rpd/ncy120. Abstract In this article, we study human electromagnetic exposure to the radiation of an ultra dense network of nodes integrated in a floor denoted as ATTO-cell floor, or ATTO-floor. ATTO-cells are a prospective 5G wireless networking technology, in which humans are exposed by several interfering sources. To numerically estimate this exposure we propose a statistical approach based on a set of finite difference time domain simulations. It accounts for variations of antenna phases and makes use of a large number of exposure evaluations, based on a relatively low number of required simulations. The exposure was expressed in peak-spatial 10-g SAR average (psSAR10g). The results show an average exposure level of ~4.9 mW/kg and reaching 7.6 mW/kg in 5% of cases. The maximum psSAR10g value found in the studied numerical setup equals around 21.2 mW/kg. Influence of the simulated ATTO-floor size on the resulting exposure was examined. All obtained exposure levels are far below 4 W/kg ICNIRP basic restriction for general public in limbs (and 20 W/kg basic restriction for occupational exposure), which makes ATTO-floor a potential low-exposure 5 G candidate. Open access paper: ncbi.nlm.nih.gov

AI evidence extraction

At a glance
Study type
Exposure assessment
Effect direction
no_effect
Population
—
Sample size
—
Exposure
RF 5G ATTO-cell (ultra-dense network integrated in floor) · 0.0049 W/kg
Evidence strength
Low
Confidence: 78% · Peer-reviewed: yes

Main findings

Using a statistical approach based on a set of finite difference time domain simulations accounting for antenna phase variations, estimated psSAR10g averaged ~4.9 mW/kg, reached 7.6 mW/kg in 5% of cases, and had a maximum around 21.2 mW/kg in the studied numerical setup. The authors report these exposure levels are far below ICNIRP basic restrictions (4 W/kg for general public in limbs; 20 W/kg for occupational exposure).

Outcomes measured

  • peak-spatial 10-g SAR average (psSAR10g)

Limitations

  • Numerical/simulation-based exposure estimation (finite difference time domain) rather than measurements in humans
  • Results pertain to the studied numerical setup; generalizability to other ATTO-floor configurations not stated

Suggested hubs

  • who-icnirp (0.6)
    Abstract explicitly compares estimated SAR to ICNIRP basic restrictions.
  • 5g-policy (0.45)
    Study concerns a prospective 5G wireless networking technology (ATTO-cells) and evaluates exposure relative to limits.
View raw extracted JSON
{
    "study_type": "exposure_assessment",
    "exposure": {
        "band": "RF",
        "source": "5G ATTO-cell (ultra-dense network integrated in floor)",
        "frequency_mhz": null,
        "sar_wkg": 0.00489999999999999984179321899091519298963248729705810546875,
        "duration": null
    },
    "population": null,
    "sample_size": null,
    "outcomes": [
        "peak-spatial 10-g SAR average (psSAR10g)"
    ],
    "main_findings": "Using a statistical approach based on a set of finite difference time domain simulations accounting for antenna phase variations, estimated psSAR10g averaged ~4.9 mW/kg, reached 7.6 mW/kg in 5% of cases, and had a maximum around 21.2 mW/kg in the studied numerical setup. The authors report these exposure levels are far below ICNIRP basic restrictions (4 W/kg for general public in limbs; 20 W/kg for occupational exposure).",
    "effect_direction": "no_effect",
    "limitations": [
        "Numerical/simulation-based exposure estimation (finite difference time domain) rather than measurements in humans",
        "Results pertain to the studied numerical setup; generalizability to other ATTO-floor configurations not stated"
    ],
    "evidence_strength": "low",
    "confidence": 0.7800000000000000266453525910037569701671600341796875,
    "peer_reviewed_likely": "yes",
    "keywords": [
        "ATTO-cell",
        "ATTO-floor",
        "5G",
        "ultra dense network",
        "exposure assessment",
        "FDTD",
        "SAR",
        "psSAR10g",
        "ICNIRP"
    ],
    "suggested_hubs": [
        {
            "slug": "who-icnirp",
            "weight": 0.59999999999999997779553950749686919152736663818359375,
            "reason": "Abstract explicitly compares estimated SAR to ICNIRP basic restrictions."
        },
        {
            "slug": "5g-policy",
            "weight": 0.450000000000000011102230246251565404236316680908203125,
            "reason": "Study concerns a prospective 5G wireless networking technology (ATTO-cells) and evaluates exposure relative to limits."
        }
    ]
}

AI can be wrong. Always verify against the paper.

AI-extracted fields are generated from the abstract/metadata and may be incomplete or incorrect. This content is for informational purposes only and is not medical advice.

Comments

Log in to comment.

No comments yet.