No evidence for genotoxicity in mice due to exposure to intermediate-frequency magnetic fields used for wireless power-transfer systems

PAPER manual Mutation research. Genetic toxicology and environmental mutagenesis 2021 Animal study Effect: no_effect Evidence: Low

Abstract

No evidence for genotoxicity in mice due to exposure to intermediate-frequency magnetic fields used for wireless power-transfer systems Shin Ohtani, Akira Ushiyama, Keiji Wada, Yukihisa Suzuki, Kazuyuki Ishii, Kenji Hattori. No evidence for genotoxicity in mice due to exposure to intermediate-frequency magnetic fields used for wireless power- transfer systems. Mutat Res. Mar-Apr 2021;863-864:503310. doi: 10.1016/j.mrgentox.2021.503310. Abstract Time varying magnetic fields (MFs) are used for the wireless power-transfer (WPT) technology. Especially, 85 kHz band MFs, which are included in the intermediate frequency (IF) band (300 Hz - 10 MHz), are commonly used WPT system for charging electric vehicles. Those applications of WPT technology have elicited public concern about health effects of IF-MF. However, existing data from health risk assessments are insufficient and additional data are needed. We assessed the genotoxic effects of IF-MF exposure on erythroid differentiation in mice. A high-intensity IF-MF mouse exposure system was constructed to induce an average whole-body electric field of 54.1 V/m. Blood samples were obtained from male mice before and after a 2-week IF-MF exposure (1 h/day, total: 10 h); X-irradiated mice were used as positive controls. We analyzed the blood samples with the micronucleus (MN) test and the Pig-a mutation assay. No significant differences were seen between IF-MF- exposed and sham-exposed mice in the frequencies of either MN or Pig-a mutations in mature erythrocytes and reticulocytes. IF-MF exposure did not induce genotoxicity in vivo under the study conditions (2.36× the basic restriction for occupational exposure, 22.9 V/m, in the International Commission on Non-Ionizing Radiation Protection (ICNIRP) guidelines). The absence of significant biological effects due to IF-MF exposure supports the practical application of this technology. Highlights • We examined the genotoxicity of IF-MF exposure >2× the ICNIRP guideline. • IF-MF had no genotoxic effects in an in vivo micronucleus test and Pig-a assay. • These observations are useful for assessing the safety of a WPT system. pubmed.ncbi.nlm.nih.gov

AI evidence extraction

At a glance
Study type
Animal study
Effect direction
no_effect
Population
Male mice
Sample size
—
Exposure
IF wireless power-transfer (WPT) system (electric vehicle charging) · 0.085 MHz · 2 weeks; 1 h/day (total 10 h)
Evidence strength
Low
Confidence: 78% · Peer-reviewed: yes

Main findings

Male mice exposed to 85 kHz intermediate-frequency magnetic fields (average whole-body electric field 54.1 V/m) for 2 weeks showed no significant differences versus sham-exposed mice in micronucleus frequencies or Pig-a mutation frequencies in mature erythrocytes and reticulocytes. Under the stated study conditions, IF-MF exposure did not induce in vivo genotoxicity.

Outcomes measured

  • Genotoxicity (micronucleus test in mature erythrocytes and reticulocytes)
  • Mutations (Pig-a mutation assay in mature erythrocytes and reticulocytes)
  • Erythroid differentiation (context of assessment)

Limitations

  • Sample size not reported in the provided abstract/metadata
  • Exposure regimen limited to 2 weeks and 10 total hours
  • Only male mice were studied
  • Endpoints limited to micronucleus test and Pig-a mutation assay in blood cells

Suggested hubs

  • who-icnirp (0.72)
    Study explicitly references ICNIRP basic restriction levels and compares exposure intensity to the guideline.
View raw extracted JSON
{
    "study_type": "animal",
    "exposure": {
        "band": "IF",
        "source": "wireless power-transfer (WPT) system (electric vehicle charging)",
        "frequency_mhz": 0.08500000000000000610622663543836097232997417449951171875,
        "sar_wkg": null,
        "duration": "2 weeks; 1 h/day (total 10 h)"
    },
    "population": "Male mice",
    "sample_size": null,
    "outcomes": [
        "Genotoxicity (micronucleus test in mature erythrocytes and reticulocytes)",
        "Mutations (Pig-a mutation assay in mature erythrocytes and reticulocytes)",
        "Erythroid differentiation (context of assessment)"
    ],
    "main_findings": "Male mice exposed to 85 kHz intermediate-frequency magnetic fields (average whole-body electric field 54.1 V/m) for 2 weeks showed no significant differences versus sham-exposed mice in micronucleus frequencies or Pig-a mutation frequencies in mature erythrocytes and reticulocytes. Under the stated study conditions, IF-MF exposure did not induce in vivo genotoxicity.",
    "effect_direction": "no_effect",
    "limitations": [
        "Sample size not reported in the provided abstract/metadata",
        "Exposure regimen limited to 2 weeks and 10 total hours",
        "Only male mice were studied",
        "Endpoints limited to micronucleus test and Pig-a mutation assay in blood cells"
    ],
    "evidence_strength": "low",
    "confidence": 0.7800000000000000266453525910037569701671600341796875,
    "peer_reviewed_likely": "yes",
    "keywords": [
        "intermediate-frequency magnetic fields",
        "IF-MF",
        "wireless power transfer",
        "WPT",
        "85 kHz",
        "electric vehicle charging",
        "genotoxicity",
        "micronucleus test",
        "Pig-a mutation assay",
        "ICNIRP guidelines",
        "in vivo",
        "mouse"
    ],
    "suggested_hubs": [
        {
            "slug": "who-icnirp",
            "weight": 0.7199999999999999733546474089962430298328399658203125,
            "reason": "Study explicitly references ICNIRP basic restriction levels and compares exposure intensity to the guideline."
        }
    ]
}

AI can be wrong. Always verify against the paper.

AI-extracted fields are generated from the abstract/metadata and may be incomplete or incorrect. This content is for informational purposes only and is not medical advice.

Comments

Log in to comment.

No comments yet.