Physical units to report intensity of electromagnetic wave

PAPER manual Environmental research 2021 Other Effect: unclear Evidence: Insufficient

Abstract

Physical units to report intensity of electromagnetic wave R Ramirez-Vazquez, I Escobar, T Franco, E Arribas. Physical units to report intensity of electromagnetic wave. Environ Res. 2021 Nov 2;112341. doi: 10.1016/j.envres.2021.112341. Abstract The aim of this work is to propose a consensus to scientific community that handles personal exposimeters, which measure intensity of an electromagnetic wave (W/m2). To express the intensity of an electromagnetic wave there is a duality in the way of expressing it. Some scientists prefer to use W/m2 while others use V/m, which is a unit of the electric field. There is also a duality in the name, sometimes it is called it power flux density and some other times, wave intensity. We believe that this second name is more appropriate from the point of view of physics. We suggest expressing intensity of an electromagnetic wave in W/m2 instead of giving the value of their electric field which is measured in V/m. There is a quadratic relation between electric field and intensity of the wave, and it is necessary to do a mathematical operation, so in our opinion, it is preferable to use W/m2 which directly gives us the value of the measured intensity. Furthermore, if the intensity is very low, it may be expressed in μW/m2 and with only three significant figures, due to sensitivity of the current exposimeters used. pubmed.ncbi.nlm.nih.gov

AI evidence extraction

At a glance
Study type
Other
Effect direction
unclear
Population
—
Sample size
—
Exposure
personal exposimeters
Evidence strength
Insufficient
Confidence: 78% · Peer-reviewed: yes

Main findings

The authors propose a consensus for reporting electromagnetic wave intensity measured by personal exposimeters, recommending use of W/m² (and µW/m² for very low intensities) rather than reporting electric field strength in V/m, citing the quadratic relationship between electric field and wave intensity and the need for conversion.

Outcomes measured

  • Reporting/measurement units for electromagnetic wave intensity (W/m² vs V/m)
  • Terminology for intensity (power flux density vs wave intensity)
  • Recommended significant figures/units for low intensities (µW/m², three significant figures)

Suggested hubs

  • exposure-assessment (0.9)
    Focuses on how to report/express EMF intensity measurements from personal exposimeters.
View raw extracted JSON
{
    "study_type": "other",
    "exposure": {
        "band": null,
        "source": "personal exposimeters",
        "frequency_mhz": null,
        "sar_wkg": null,
        "duration": null
    },
    "population": null,
    "sample_size": null,
    "outcomes": [
        "Reporting/measurement units for electromagnetic wave intensity (W/m² vs V/m)",
        "Terminology for intensity (power flux density vs wave intensity)",
        "Recommended significant figures/units for low intensities (µW/m², three significant figures)"
    ],
    "main_findings": "The authors propose a consensus for reporting electromagnetic wave intensity measured by personal exposimeters, recommending use of W/m² (and µW/m² for very low intensities) rather than reporting electric field strength in V/m, citing the quadratic relationship between electric field and wave intensity and the need for conversion.",
    "effect_direction": "unclear",
    "limitations": [],
    "evidence_strength": "insufficient",
    "confidence": 0.7800000000000000266453525910037569701671600341796875,
    "peer_reviewed_likely": "yes",
    "keywords": [
        "personal exposimeters",
        "electromagnetic wave intensity",
        "power flux density",
        "wave intensity",
        "W/m2",
        "V/m",
        "electric field",
        "reporting units",
        "significant figures",
        "µW/m2"
    ],
    "suggested_hubs": [
        {
            "slug": "exposure-assessment",
            "weight": 0.90000000000000002220446049250313080847263336181640625,
            "reason": "Focuses on how to report/express EMF intensity measurements from personal exposimeters."
        }
    ]
}

AI can be wrong. Always verify against the paper.

AI-extracted fields are generated from the abstract/metadata and may be incomplete or incorrect. This content is for informational purposes only and is not medical advice.

Comments

Log in to comment.

No comments yet.