Measurement of Electromagnetic Fields Exposure to Humans from Electric Vehicles and Their Supply Equipment
This study reports measurements of electric field intensity (E) and magnetic flux density (B) from electric vehicles (inside driver/passenger seats during driving) and EV supply equipment (near chargers during charging) up to 400 kHz in and around Chennai. E and B inside EVs and E around EVSEs were reported to be within ICNIRP/IEEE guideline limits. However, B around certain EVSE positions reportedly exceeded a general public threshold (~200 T), and a preliminary FEM analysis suggested relatively higher fields at charging infrastructure. The authors call for further research on long-term health impacts and recommend policy actions to mitigate exposure.
Magnetic Field Measurement of Various Types of Vehicles, Including Electric Vehicles
This exposure assessment measured magnetic fields inside modern Japanese EVs, PHEVs, and ICEVs during actual driving using methods aligned with IEC 62764-1:2022. All measured magnetic flux density values were reported to be below ICNIRP public exposure reference levels. The study mapped in-cabin field sources and noted methodological differences may explain higher transient spikes reported in some international studies.
Impact of magnetic fields from tablets, laptops, smartphones, and household/leisure magnets on cardiac implantable electronic devices
This study tested magnetic fields from tablets, laptops, smartphones, and household/leisure magnets against 13 cardiac implantable electronic device (CIED) models to assess magnet mode activation. It reports that these consumer devices can trigger magnet mode when in close proximity, with median activation distances of 5–6.5 mm for phones/tablets/laptops and mainly contact-level activation for household/leisure magnets. None of the tested devices activated magnet mode at distances of 20 mm or more, and the authors emphasize patient awareness of proximity-related risk.
Effect of short-term extremely low-frequency electromagnetic field on respiratory functions
This animal study tested whether short-term ELF-EMF exposure alters respiratory physiology in rats. Twenty Wistar albino rats were assigned to control or EMF exposure (50 Hz, 0.3 mT for 2 minutes) with respiratory parameters measured before, during, and after exposure. The study reports changes during exposure (lower respiratory rate and higher cycle duration, inspiration time, and tidal volume) but no differences after exposure, and it frames the findings as relevant to EMF safety and potential health risks.
20 kHz Magnetic Field Emission of Induction Cooking Heaters
This exposure assessment measured 20 kHz magnetic field leakage from induction cooking heaters across four models and compared results with ICNIRP general public limits. The maximum reported magnetic flux density was 16 µT at a specified measurement point using two S-type pans. Field leakage depended on pan size and configuration, and finite element modeling was reported to align closely with measurements.