Archive

5 posts

Filters: tag: Ischemic Stroke Clear

EMAGINE-Study protocol of a randomized controlled trial for determining the efficacy of a frequency tuned electromagnetic field treatment in facilitating recovery within the subacute phase following ischemic stroke.

Research RF Safe Research Library Jan 1, 2023

This paper presents the protocol for the EMAGINE multicenter, double-blind, randomized, sham-controlled trial testing an extremely low-frequency, low-intensity, frequency-tuned electromagnetic field therapy (ENTF) after subacute ischemic stroke. Participants will start active or sham treatment 4–21 days post-stroke,…

Frequency-tuned electromagnetic field therapy improves post-stroke motor function: A pilot randomized controlled trial.

Research RF Safe Research Library Jan 1, 2022

This pilot randomized, sham-controlled, double-blind trial evaluated extremely low frequency, low-intensity ENTF electromagnetic field therapy in subacute ischemic stroke patients with impaired upper extremity function. The per-protocol results reported greater improvements in motor function and disability outcomes…

Extremely low frequency electromagnetic field reduces oxidative stress during the rehabilitation of post-acute stroke patients.

Research RF Safe Research Library Jan 1, 2018

This study evaluated ELF-EMF magnetotherapy as an adjunct to post-acute ischemic stroke rehabilitation in 57 patients, comparing those who received ELF-EMF therapy with those who did not. The authors report that oxidative stress markers (TBARS, thiol, and carbonyl groups) decreased more in the ELF-EMF group than in…

Extremely low frequency electromagnetic field (ELF-EMF) reduces oxidative stress and improves functional and psychological status in ischemic stroke patients.

Research RF Safe Research Library Jan 1, 2017

This clinical study evaluated whether adding ELF-EMF exposure to a 4-week rehabilitation program affects antioxidant and clinical status in ischemic stroke patients. Fifty-seven patients were assigned to an ELF-EMF group or a non-ELF-EMF group, with the exposed group receiving 40 Hz, 7 mT for 15 minutes per day over…

Characterization of thrombus stiffening in radio frequency (rf) Mechanical thrombectomy.

Research RF Safe Research Library Jan 1, 2016

This engineering-focused conference paper characterizes thrombus stiffening after radio frequency (rf) electric current treatment in the context of intra-arterial mechanical thrombectomy. The abstract reports thrombus stiffness increased by more than eightfold after rf treatment, attributed to increased crosslinking.…

Page 1 / 1