Archive

5 posts

Showing results for: measured exposure

In-Situ Measurements of Radiofrequency Electromagnetic Fields Measurements Around 5G Macro Base Stations in the UK

Research RF Safe Research Library Jan 1, 2025

This exposure assessment performed RF spot measurements in line-of-sight to 56 active 5G macro base stations across 30 publicly accessible UK locations. Power density was measured across 420 MHz–6 GHz under multiple scenarios (background, streaming, downlink speed test, and extrapolated SS-RSRP decoding). Reported…

Assessing RF EMF exposure in multiple microenvironments across ten European countries with a focus on 5G

Research RF Safe Research Library Jan 1, 2025

This exposure assessment measured environmental and auto-induced RF-EMF across more than 800 microenvironments in ten European countries, with a focus on 5G-related bands. Non-user environmental exposure was reported to be below international guideline values and similar to prior European research, while induced…

Dose Estimation for Indoor Radon, Occupational Radiation, and Electromagnetic Field Exposure in a Nuclear Medicine Department in Turkiye.

Research RF Safe Research Library Jan 1, 2025

This 1-year monitoring study assessed occupational ionizing radiation dose, indoor radon, and EMF-related electric field levels in a nuclear medicine department in Turkiye. Radiation worker doses were tracked with electronic personnel dosimeters, radon was measured at 2-month intervals to estimate annual dose and…

Wi-fi related radiofrequency electromagnetic fields (RF-EMF): a pilot experimental study of personal exposure and risk perception.

Research RF Safe Research Library Jan 1, 2021

This pilot experimental study tested whether different types of information (basic text, precautionary information, or personal RF-EMF exposure measurements) affect perceptions of Wi-Fi (2.4 GHz) RF-EMF. Risk perception and exposure perception did not differ by the type of information provided, although receiving…

APPLICATION OF TIME-AVERAGED AND INTEGRAL-BASED MEASURE FOR MEASUREMENT RESULTS VARIABILITY REDUCTION IN GSM/DCS/UMTS SYSTEMS.

Research RF Safe Research Library Jan 1, 2019

This exposure-assessment study evaluated temporal variability of RF-EMF levels from GSM/DCS/UMTS networks using continuous personal exposimeter logging. It proposes an integral-based measure (accumulated energy density from instantaneous power density) alongside 24 h time-averaging to reduce variability in daily…