2 postsIn-Situ Measurements of Radiofrequency Electromagnetic Fields Measurements Around 5G Macro Base Stations in the UK
This exposure assessment performed RF spot measurements in line-of-sight to 56 active 5G macro base stations across 30 publicly accessible UK locations. Power density was measured across 420 MHz–6 GHz under multiple scenarios (background, streaming, downlink speed test, and extrapolated SS-RSRP decoding). Reported total RF and 5G-specific levels were within 1998 ICNIRP public reference levels, with 4G downlink contributing most of the measured exposure.
Efficient design of electromagnetic field exposure maps with multi-method evolutionary ensembles
This engineering/methods study proposes an evolutionary computation approach (PCRO-SL) to optimize the selection of measurement points for constructing RF-EMF exposure maps. Tested on real measurements in Meco (Madrid, Spain), it reports good agreement with a reference exposure map while reducing required sampling density. The authors provide practical point-selection rules (e.g., line-of-sight within 250 m and directional sampling within 500 m) intended to maintain representativeness and avoid interpolation artifacts.