Impact of magnetic fields from tablets, laptops, smartphones, and household/leisure magnets on cardiac implantable electronic devices
Research
RF Safe Research Library
Jan 1, 2025
This study tested magnetic fields from tablets, laptops, smartphones, and household/leisure magnets against 13 cardiac implantable electronic device (CIED) models to assess magnet mode activation. It reports that these consumer devices can trigger magnet mode when in close proximity, with median activation distances…
An Out-of-Phase Wireless Power Transfer System for Implantable Medical Devices to Reduce Human Exposure to Electromagnetic Field and Increase Power Transfer Efficiency.
Research
RF Safe Research Library
Jan 1, 2022
This engineering study proposes an out-of-phase coupled wireless power transfer system for implantable medical devices intended to reduce electromagnetic field exposure in the tissue region between transmitting and receiving coils. The authors report, via simulation and measurements, lower EMF and higher power…
Evaluation of the safety of users of active implantable medical devices (AIMD) in the working environment in terms of exposure to electromagnetic fields - Practical approach to the requirements of European Directive 2013/35/EU.
Research
RF Safe Research Library
Jan 1, 2018
This study assessed electromagnetic field exposure near common strong EMF sources in medical and industrial workplaces to estimate standard safety distances (SSD) for workers using active implantable medical devices (AIMD). Using measurements near 127 devices, the longest SSDs were reported near dielectric sealers…
In Vivo Wireless Monitoring System of Cardiovascular Force Data.
Research
RF Safe Research Library
Jan 1, 2015
This paper describes development of a fully implantable biotelemetry system that wirelessly transmits cardiac biomechanical force data along with ECG. The system uses a microcontroller with a bidirectional RF transceiver and was tested in a porcine model. The authors report successful transmission and recording of…
A mm-sized wirelessly powered and remotely controlled locomotive implant.
Research
RF Safe Research Library
Jan 1, 2012
This engineering paper describes a mm-scale implantable device that is wirelessly powered and remotely controlled to locomote in a fluid medium. The prototype is reported to receive 500 µW from a 2 W, 1.86 GHz RF power signal at 5 cm and to support 2.5–25 Mbps data rates using asynchronous PWM on the carrier. The…
Isolated Atrial Lead Conduction Delay following Right Atrial Radiofrequency Maze Procedure.
Research
RF Safe Research Library
Jan 1, 2011
This case report describes a 60-year-old man with a dual-chamber implantable cardioverter defibrillator who underwent septal myectomy and a right atrial radiofrequency maze procedure. Following surgery, a persistent delay in atrial sensing was observed. The authors attribute this most likely to iatrogenic right…
In vitro tests reveal sample radiofrequency identification readers inducing clinically significant electromagnetic interference to implantable pacemakers and implantable cardioverter-defibrillators.
Research
RF Safe Research Library
Jan 1, 2010
This in vitro study tested electromagnetic compatibility between passive RFID readers and 15 pacemakers plus 15 ICDs across 134 kHz, 13.56 MHz, and 915 MHz bands. EMI reactions were common with low-frequency RFID and rare with high-frequency RFID, while no reactions were observed with ultra-high-frequency or…
Improvement in magnetic field immunity of externally-coupled transcutaneous energy transmission system for a totally implantable artificial heart.
Research
RF Safe Research Library
Jan 1, 2008
This engineering study addresses interference between induction-heating cookers and an externally coupled transcutaneous energy transmission system for a totally implantable artificial heart. The authors report that magnetic flux from an IH cooker can couple into the TET transformer and affect system performance. A…