Comparison Between Broadband and Personal Exposimeter Measurements for EMF Exposure Map Development Using Evolutionary Programming
Research
RF Safe Research Library
Jan 1, 2025
This exposure-assessment study compares RF-EMF exposure maps produced using a broadband meter versus a personal exposimeter and aims to correct personal exposimeter readings to match broadband-based maps. The authors report that LOS/NLOS-specific correction factors reduce discrepancies, particularly improving LOS…
Supervised Machine Learning Algorithms for Bioelectromagnetics: Prediction Models and Feature Selection Techniques Using Data from Weak Radiofrequency Radiation Effect on Human and Animals Cells.
Research
RF Safe Research Library
Jan 1, 2020
This paper develops supervised machine-learning prediction models to analyze potential impacts of weak RF-EMF on human and animal cells using extracted laboratory experimental data from prior publications. Data from 300 peer-reviewed papers (1127 experimental case studies) were used with feature selection and…
Radiofrequency applicator concepts for thermal magnetic resonance of brain tumors at 297 MHz (7.0 Tesla).
Research
RF Safe Research Library
Jan 1, 2020
This engineering/simulation study evaluates RF applicator concepts for ThermalMR brain tumor heating at 297 MHz (7.0 Tesla) using clinically realistic GBM-based models. EMF simulations compared 10 applicator designs and two SAR-based planning algorithms for small and large target volumes. Power-focused optimization…
Demonstration of long-distance hazard-free wearable EEG monitoring system using mobile phone visible light communication.
Research
RF Safe Research Library
Jan 1, 2017
This paper describes an engineering approach to avoid RF/microwave radiation in wearable EEG data transmission by using visible light communication. The system performance was tested at different illuminance levels and an algorithm for low-illuminance operation was proposed. The authors report error-free transmission…
[Study of the influence of uniform transverse magnetic field on the dose distribution of high energy electron beam using Monte Carlo method].
Research
RF Safe Research Library
Jan 1, 2014
This engineering/medical physics study used Monte Carlo simulations to examine how a uniform transverse magnetic field affects the dose distribution of a 30 MeV electron beam in a water phantom. The abstract reports substantial changes in depth-dose, including reduced range and a pronounced end-of-range dose peak…
Real Time Processing and Transferring ECG Signal by a Mobile Phone.
Research
RF Safe Research Library
Jan 1, 2014
This paper presents an engineering approach for real-time ECG signal processing on a mobile phone with remote transmission to a medical center. The method uses an IIR low-pass filter and Hilbert transform to support R-peak detection and arrhythmia alerting. Reported algorithm performance includes 96.97% sensitivity…
Comparison between different thickness umbrella-shaped expandable radiofrequency electrodes (SuperSlim and CoAccess): Experimental and clinical study.
Research
RF Safe Research Library
Jan 1, 2011
This experimental and clinical study compared two umbrella-shaped expandable radiofrequency ablation electrodes (SuperSlim vs CoAccess) across different ablation algorithms. In ex vivo bovine liver, CoAccess generally produced larger ablation areas and required longer ablation times than SuperSlim, with no…
Evaluation of mulitprobe radiofrequency technology in a porcine model.
Research
RF Safe Research Library
Jan 1, 2007
This animal study evaluated two multiprobe radiofrequency ablation device approaches in pigs, including an impedance-based algorithm and clustered/combination probes with and without a switcher controller. The Pringle maneuver was associated with larger ablation volumes and shorter ablation times in one experiment,…