Archive

253 posts

Showing results for: RIBE

Fuzzy mobile-robot positioning in intelligent spaces using wireless sensor networks.

Research RF Safe Research Library Jan 1, 2011

This engineering study develops and experimentally evaluates a fuzzy-logic method for locating mobile robots in an intelligent space using wireless sensor networks. Localization relies on inter-node range measurements estimated from RF signal strength attenuation, which the authors describe as noisy and unreliable.…

Interoperation of an UHF RFID reader and a TCP/IP device via wired and wireless links.

Research RF Safe Research Library Jan 1, 2011

This engineering paper describes a system implementation for interoperation between a 915 MHz UHF RFID reader and a TCP/IP gateway device. The architecture uses wired communication between the TCP/IP device and RFID reader, and wireless ZigBee (IEEE 802.15.4) links to an end-device/coordinator. Web-based tests are…

Historical building monitoring using an energy-efficient scalable wireless sensor network architecture.

Research RF Safe Research Library Jan 1, 2011

This engineering paper describes low-power wireless sensor nodes and a cluster-based dynamic-tree hierarchical WSN architecture for monitoring historical buildings and wooden artifacts for early pest detection. The authors report simulation and demonstration results indicating improved scalability and reliability…

Response identification in the extremely low frequency region of an electret condenser microphone.

Research RF Safe Research Library Jan 1, 2011

This engineering study describes an experimental setup using a small electret condenser microphone connected to a notebook/PC to detect extremely low frequency signals. Using a small air cell made from a drilled DVD plate with a speaker and microphone on opposite sides, the microphone captured signals in the 0.5–20…

Design and implementation of a wireless sensor network-based remote water-level monitoring system.

Research RF Safe Research Library Jan 1, 2011

This article reports an engineering implementation of a wireless sensor network-based remote water-level monitoring system. The system includes field sensors, a base station, a data center, and a web publishing module, and is described as providing real-time monitoring and anti-jamming capability. The authors state…

Effects of extremely low frequency magnetic field on oxidative balance in brain of rats.

Research RF Safe Research Library Jan 1, 2011

This animal study examined whether an extremely low frequency magnetic field (7 mT, 40 Hz) used in magnetotherapy alters oxidative balance in rat brain after 10 days of exposure. The 30 min/day exposure condition was associated with increased lipid peroxidation, while the 60 min/day condition was associated with…

Measurement of creatine kinase reaction rate in human brain using magnetization transfer image-selected in vivo spectroscopy (MT-ISIS) and a volume ³¹P/¹H radiofrequency coil in a clinical 3-T MRI system.

Research RF Safe Research Library Jan 1, 2011

This paper describes a new magnetization transfer 31P MRS approach (MT-ISIS) for measuring the creatine kinase forward reaction rate in the human brain using a volume 31P/1H RF coil on a clinical 3-T MRI system. The method aims to reduce acquisition time (30 min), avoid scalp muscle contamination, improve RF…

Reduction of implant RF heating through modification of transmit coil electric field.

Research RF Safe Research Library Jan 1, 2011

This engineering study describes modifying MRI RF transmit coil electric-field distributions to create electric field-free zones without substantially changing transmit sensitivity. Phantom experiments are reported to show reduced implant heating when a zero electric-field plane is aligned with the implant location.…

Impact of a static magnetic field on the electricity production of Shewanella-inoculated microbial fuel cells.

Research RF Safe Research Library Jan 1, 2011

This study investigated how exposure to a static magnetic field affects electricity production in Shewanella-inoculated microbial fuel cells across different reactor configurations. A 100 mT field was reported to increase maximum voltage and the effect was described as immediate and reversible, with possible adverse…

Correction of main and transmit magnetic field (B0 and B1) inhomogeneity effects in multicomponent-driven equilibrium single-pulse observation of T1 and T2.

Research RF Safe Research Library Jan 1, 2011

This methods paper addresses how B0 (main field) and B1 (transmit field) inhomogeneities can bias SPGR and bSSFP steady-state MRI signals used for multicomponent T1/T2 relaxometry and myelin water analysis. It describes using DESPOT1-HIFI to calibrate flip angles and adding a B0-related parameter with multiple…

A rapid and facile synthesis of nanofibrillar polyaniline using microwave radiation.

Research RF Safe Research Library Jan 1, 2010

This engineering study describes a microwave-assisted method to synthesize polyaniline (PANI) nanofibers. Reported yields under microwave irradiation were similar to conventional synthesis but achieved in minutes rather than hours. Structural and morphological characterization (FTIR, Raman, SEM, TEM) reportedly…

Orientation and Dynamics of ZnO Nanorod Liquid Crystals in Electric Fields.

Research RF Safe Research Library Jan 1, 2010

This materials study reports that ZnO nanorod polymer hybrids can form liquid-crystalline phases and exhibit orientation switching under an applied AC electric field. The orientation reportedly changes from planar to homeotropic, analogous to switching in low-molecular liquid crystals. Dielectric measurements and…

Electrooptical effects in colloid systems subjected to short pulses of strong electric field.

Research RF Safe Research Library Jan 1, 2010

This study describes an electrooptical technique for polydisperse colloid solutions using short pulses of strong sine-shaped electric field, intended for systems that cannot withstand prolonged field exposure. The authors report that key particle parameters can still be extracted from the resulting experimental data.…

Interaction quench dynamics in the Kondo model in the presence of a local magnetic field.

Research RF Safe Research Library Jan 1, 2010

This theoretical study analyzes quench dynamics in the Kondo model on the Toulouse line in the presence of a local magnetic field. The authors report exact analytical results for local spin dynamics, finding that relaxation timescales are set by the Kondo scale. They also describe damped transient oscillations in…

Electronic properties of a graphene antidot in magnetic fields.

Research RF Safe Research Library Jan 1, 2010

This paper describes unusual electronic properties of a graphene antidot created by a piecewise constant potential in a magnetic field. It reports near-complete localization of electron probability within the barrier region under some conditions and a symmetry linking antidot and dot states with identical…

Anomalous magnetic field dependence of Y Ba(2)Cu(3)O(7 - δ): effect of orthorhombic distortion.

Research RF Safe Research Library Jan 1, 2010

This paper presents a theoretical model to investigate the origin of a mixed symmetry pairing state in the high-Tc superconductor YBa2Cu3O7-δ under applied magnetic fields between Hc1 and Hc2. The authors report that the model’s results, and their stated agreement with relevant experimental data, suggest orthorhombic…

The modulation of the de Haas-van Alphen effect in graphene by electric field.

Research RF Safe Research Library Jan 1, 2010

This theoretical/physics paper examines how an in-plane uniform electric field affects the de Haas-van Alphen (dHvA) effect in graphene. It reports that magnetization, magnetic susceptibility, and dHvA oscillation behavior depend on a dimensionless parameter β = E/(vF B), with divergences described at a critical…

Nanocrystalline hydroxyapatite bioceramic using microwave radiation: Synthesis and characterization.

Research RF Safe Research Library Jan 1, 2010

This engineering/materials study synthesized nanocrystalline hydroxyapatite bioceramic powder using microwave radiation and then characterized the resulting material. The authors report highly crystalline HAp nanopowder with nanoscale size, mixed morphology, and elemental composition consistent with the HAp phase.…

Electromagnetic fields and DNA damage

Research RF Safe Research Library Jan 1, 2009

This review discusses the comet assay and summarizes research on non-ionizing EMF exposure and DNA/chromosomal damage. It describes both positive and negative findings across studies, noting no consistent overall pattern for radiofrequency radiation (RFR). The authors nonetheless conclude that under certain exposure…

Scientific Committee on Emerging and Newly Identified Health Risks

Research RF Safe Research Library Jan 1, 2009

This SCENIHR Opinion updates earlier 2009 SCENIHR documents on EMF health effects and research needs, focusing on new information and remaining knowledge gaps. The abstract primarily characterizes sources and patterns of exposure across static, ELF, IF, and RF fields in both public and occupational settings. It notes…

The use of pulsed radiofrequency treatment for chronic benign pancreatitis pain.

Research RF Safe Research Library Jan 1, 2009

This paper reports on pulsed radiofrequency treatment as an interventional approach for pain due to chronic benign pancreatitis. The authors describe their experience in two patients and characterize the technique as minimally neurodestructive and potentially able to reduce pain perception by altering nerve…

The use of a standard radiofrequency energy delivery system to facilitate transseptal puncture.

Research RF Safe Research Library Jan 1, 2009

This paper describes a procedural technique for transseptal puncture that uses brief pulses of radiofrequency energy delivered from a standard electrosurgical cautery generator through the needle tip. The approach is presented as a way to facilitate septal traversal when tissue is elastic, aneurysmal, or thickened,…

Biological proton pumping in an oscillating electric field.

Research RF Safe Research Library Jan 1, 2009

This paper models biological proton pumping in cytochrome c oxidase under an applied oscillating electric field. The authors report that proton pumping efficiency and steady-state electronic currents vary significantly with the field’s frequency and amplitude. A spectral analysis is described as supporting dominant…

Electric field switching of the magnetic anisotropy of a ferromagnetic layer exchange coupled to the multiferroic compound BiFeO3.

Research RF Safe Research Library Jan 1, 2009

This paper reports electric-field control of magnetic anisotropy in a Permalloy layer exchange-coupled to a multiferroic BiFeO3 single crystal. The anisotropy is described as arising from magnetic coupling to canted spins in BiFeO3’s cycloidal antiferromagnetic structure. An electric field-induced polarization change…

Magnetic field delocalization and flux inversion in fractional vortices in two-component superconductors.

Research RF Safe Research Library Jan 1, 2009

This theoretical paper analyzes vortex solutions in two-component superconductors within a U(1) x U(1) Ginzburg-Landau framework. It reports that exponentially screened magnetic fields are only found in special cases, while most parameter choices yield delocalized magnetic fields with slowly decaying tails. It also…

← Prev Page 9 / 11 Next →