Archive

117 posts

Showing results for: MPE

Nanocrystalline hydroxyapatite bioceramic using microwave radiation: Synthesis and characterization.

Research RF Safe Research Library Jan 1, 2010

This engineering/materials study synthesized nanocrystalline hydroxyapatite bioceramic powder using microwave radiation and then characterized the resulting material. The authors report highly crystalline HAp nanopowder with nanoscale size, mixed morphology, and elemental composition consistent with the HAp phase.…

A comparison of conventional and radio frequency defrosting of lean beef meats: Effects on water binding characteristics.

Research RF Safe Research Library Jan 1, 2009

This study compared slow conventional air defrosting with fast radio frequency (RF) defrosting/tempering in lean beef (whole, minced, and comminuted) using drip loss, NMR relaxometry, and dielectric spectroscopy. RF thawing was associated with lower drip loss and lower micronutrient loss in drip than air thawing,…

Extraordinary magnetic field enhancement with metallic nanowire: role of surface impedance in Babinet's principle for sub-skin-depth regime.

Research RF Safe Research Library Jan 1, 2009

This paper proposes metallic nanowires as complementary structures to metallic nanogaps for enhancing magnetic fields. It reports magnetic field enhancement up to a factor of 300 and presents a surface-impedance-based analytic theory that is numerically confirmed. The authors also report that, in the sub-skin-depth…

Apparent violation of the Wiedemann-Franz law near a magnetic field tuned metal-antiferromagnetic quantum critical point.

Research RF Safe Research Library Jan 1, 2008

This paper reports calculations of interlayer electrical and thermal resistivity in a layered metal assuming Fermi-liquid quasiparticles inelastically scattered by two-dimensional antiferromagnetic spin fluctuations. The model yields linear-in-temperature behavior over a broad range and suggests that extrapolations…

Silicon-on-insulator-based radio frequency single-electron transistors operating at temperatures above 4.2 K.

Research RF Safe Research Library Jan 1, 2008

This engineering study demonstrates a silicon-on-insulator (SOI) radio-frequency single-electron transistor (RF-SET) operating at temperatures above 4.2 K. The device was optimized to address high resistance in SOI SETs and showed stable transport characteristics after repeated thermal cycling. RF-SET operation was…

Effect of temperature (-5 to 130 degrees C) and fiber direction on the dielectric properties of beef Semitendinosus at radio frequency and microwave frequencies.

Research RF Safe Research Library Jan 1, 2008

This study measured dielectric properties of beef Semitendinosus across 27, 915, and 1800 MHz and temperatures from -5 to 130 °C using an open-ended coaxial probe. The results indicate that frequency, temperature, and muscle fiber orientation influence dielectric constant, dielectric loss, and calculated penetration…

Plasma-assembled carbon nanotubes: electric field-related effects.

Research RF Safe Research Library Jan 1, 2008

This engineering-focused paper compares carbon nanotube growth in dense low-temperature plasma versus on a substrate surface using hybrid/Monte-Carlo simulations. It reports that plasma parameters strongly influence ion fluxes and nanotube growth kinetics, with large differences in growth rates and fluxes between…

[Microstrip antenna design and system research of radio frequency identification temperature sensor].

Research RF Safe Research Library Jan 1, 2008

This engineering paper introduces an RFID sensor network concept integrating RFID with wireless sensor networks and emphasizes the role of antennas. It discusses coil, dipole, and microstrip antennas and reports designing a microstrip antenna for a wireless temperature monitoring and control system. Measurements are…

Radiofrequency dosimetry in subjects implanted with metallic straight wires: a numerical study.

Research RF Safe Research Library Jan 1, 2008

This numerical FDTD study modeled RF exposure at 900 and 1800 MHz in tissue containing thin metallic straight wire implants. The model indicates that the wire can substantially increase local SAR, creating high SAR gradients. Despite this, the authors report that exposures below current safe levels resulted in…

Combined effect of temperature and pulsed electric fields on apple juice peroxidase and polyphenoloxidase inactivation.

Research RF Safe Research Library Jan 1, 2008

This laboratory study evaluated pulsed electric fields (PEF) combined with preheating to inactivate peroxidase (POD) and polyphenoloxidase (PPO) in freshly prepared apple juice. The highest reported inactivation occurred with preheating to 50°C and PEF at 40 kV/cm for 100 μs, exceeding the reductions seen with…

Position-independent chemical quantitation with passive 13.56-MHz radio frequency identification (RFID) sensors.

Research RF Safe Research Library Jan 1, 2008

This engineering study evaluates whether passive 13.56-MHz RFID-based chemical sensors can quantify analytes reliably despite repositioning errors between the sensor and pickup coil. Using simultaneous measurement of multiple complex-impedance parameters and multivariate statistical analysis, the authors report…

In-line application of electric field in capillary separation systems: Joule heating, pH and conductivity.

Research RF Safe Research Library Jan 1, 2008

This engineering study investigated factors affecting current when an electric field is applied in-line in a capillary separation system. Temperature measurements and a replicated cooling setup were used to estimate Joule heating effects, which were reported to be relatively small. In contrast, significant pH shifts…

A benzene-core trinuclear GdIII complex: towards the optimization of relaxivity for MRI contrast agent applications at high magnetic field.

Research RF Safe Research Library Jan 1, 2008

This chemistry/engineering study reports the synthesis and NMR/MRI-relevant characterization of a trinuclear Gd(III) chelate intended for high-field MRI contrast applications. Using 17O NMR and proton relaxivity across multiple fields and temperatures, the authors infer bishydration, quantify water exchange and…

Evaluation of mulitprobe radiofrequency technology in a porcine model.

Research RF Safe Research Library Jan 1, 2007

This animal study evaluated two multiprobe radiofrequency ablation device approaches in pigs, including an impedance-based algorithm and clustered/combination probes with and without a switcher controller. The Pringle maneuver was associated with larger ablation volumes and shorter ablation times in one experiment,…

Dependence of RF heating on SAR and implant position in a 1.5T MR system.

Research RF Safe Research Library Jan 1, 2007

This phantom study measured RF-induced heating of a stainless steel humerus implant during 1.5T MR imaging while varying SAR, implant angle to B0, and implant position in the RF coil. Temperature rise at implant tips increased linearly with SAR, with larger rises when the implant was parallel to B0. Heating decreased…

Magnetic field switching between the two orbital-ordered states in DyVO3.

Research RF Safe Research Library Jan 1, 2007

This Physical Review Letters study investigates phase competition between spin- and orbital-ordered states in a DyVO3 single crystal. The abstract reports reentrant temperature-driven transitions in spin ordering and orbital ordering. It also reports that an applied magnetic field can switch between orbital-ordered…

The Effectiveness of a Conductive Patch and a Conductive Bed Pad in Reducing Induced Human Body Voltage Via the Application of Earth Ground

Research RF Safe Research Library Jan 1, 2005

This engineering-style study measured voltage induced on the human body via capacitive coupling to the environment using a high-impedance measurement head. It then applied earth grounding through a conductive patch and a conductive bed pad. Both grounding methods reportedly reduced coupled 60 Hz mains voltage by at…

← Prev Page 5 / 5