Simulation of colloidal fouling by coupling a dynamically updating velocity profile and electric field interactions with Force Bias Monte Carlo methods for membrane filtration.
Research
RF Safe Research Library
Jan 1, 2013
This engineering simulation study models colloidal particle transport and deposition in a membrane filtration channel at a particle volume fraction of 10%. The model couples a dynamically updating crossflow velocity field with particle-particle and particle-membrane interaction potentials (electrostatic double layer…
Induction of thrombosis of the abdominal aneurysm sac through the application of radiofrequency. An experimental study.
Research
RF Safe Research Library
Jan 1, 2012
This experimental animal study evaluated whether a radiofrequency method could induce thrombosis within an abdominal aortic aneurysm sac to potentially prevent endoleaks after endovascular repair. Six dogs received radiofrequency blood clotting of the sac and then stent-grafting, compared with a historical group of…
Nanosecond pulse electric field activation of platelet-rich plasma reduces myocardial infarct size and improves left ventricular mechanical function in the rabbit heart.
Research
RF Safe Research Library
Jan 1, 2012
This animal and in vitro study evaluated nanosecond pulsed electric fields (nsPEF) as a nonchemical method to activate platelet-rich plasma (PRP) for cardioprotection. In rabbits undergoing brief coronary occlusion followed by reperfusion, PRP injection into ischemic myocardium was associated with reduced infarct…
Tunable optical antennas based on metallic nanoshells with nanoknobs.
Research
RF Safe Research Library
Jan 1, 2012
This engineering study investigates a plasmonic nanostructure composed of a spherical metallic nanoshell with a small metallic nanoparticle (“nanoknob”) on its surface. It reports tunable plasmon resonance behavior driven by nanoshell properties and localized/enhanced electromagnetic fields near the nanoknob under…
Comparison of 2 methods of non-invasive treatment between transcutaneous electrical stimulation and pulsed electromagnetic field stimulation as replacement of invasive manual acupuncture.
Research
RF Safe Research Library
Jan 1, 2012
This study compared two non-invasive acupoint stimulation methods—TEAS and PEMF—as alternatives to manual acupuncture for recovery from exercise-induced muscle fatigue. Using 2 Hz stimulation (PEMF magnetic flux 30.92 mT), the authors report faster recovery of EMG median frequency and improved peak torque recovery in…
Construction of solar-wind-like magnetic fields.
Research
RF Safe Research Library
Jan 1, 2012
This Letter presents a method for constructing solar-wind-like magnetic fields that are nearly constant in magnitude, divergence-free, and match any specified fluctuation power spectrum. The approach selects relative phases between two polarizations per wave vector to minimize variance in field magnitude while…
Influence of magnetic field on aqueous two-phase extraction of horse ferritin in the polyethylene glycol/hydroxyethyl starch system.
Research
RF Safe Research Library
Jan 1, 2012
This study reports an aqueous two-phase extraction method for equine spleen ferritin using polyethylene glycol (PEG) and hydroxyethyl starch (HES). Ferritin partitioning depended on PEG/HES concentrations and PEG molecular weight, and applying a magnetic field increased ferritin accumulation in the PEG-rich phase…
Influences of electric field on living cells in a charged water-in-oil droplet under electrophoretic actuation.
Research
RF Safe Research Library
Jan 1, 2011
This experimental study examined whether strong electric fields used for electrophoretic actuation of charged water-in-oil droplets affect living cells inside the droplets. Using Trypan blue and cell growth tests across electric field strengths of 1–3 kV/cm and varying actuation times, the authors report no…
Correction of microcirculatory disturbances with terahertz electromagnetic radiation at nitric oxide frequencies in albino rats under conditions of acute stress.
Research
RF Safe Research Library
Jan 1, 2011
This animal study reports that terahertz electromagnetic irradiation at nitric oxide (NO)-related frequencies (150.176150.664 GHz) corrected peripheral microcirculatory disturbances in albino rats experiencing acute immobilization stress. The abstract frames the effect as a correction of stress-related peripheral…
Milk processed by pulsed electric fields: evaluation of microbial quality, physicochemical characteristics, and selected nutrients at different storage conditions.
Research
RF Safe Research Library
Jan 1, 2011
This study evaluated pulsed electric fields (PEF) as a pasteurization method for raw skim and whole milk across multiple treatment intensities and storage conditions. The abstract reports only minor changes in physicochemical properties and small decreases in some composition measures under stronger treatments.…
Template-free synthesis and self-assembly of aligned nickel nanochains under magnetic fields.
Research
RF Safe Research Library
Jan 1, 2011
This engineering/materials study describes a template-free solution-phase method to synthesize well-aligned nickel nanochains under applied magnetic fields. The authors report that nanochain size and morphology can be tuned by reaction temperature and magnetic field conditions, and explain alignment via magnetic…
Nanocrystalline graphite films nucleation by the radio frequency bias pretreatment.
Research
RF Safe Research Library
Jan 1, 2011
This paper describes an engineering method for nucleating nanocrystalline carbon films on monocrystalline silicon using a combination of microwave and radio frequency plasma-assisted chemical vapor deposition. The approach is demonstrated via deposition of nanocrystalline diamond after a seeding step and growth of…
Dynamic control of adsorption sensitivity for photo-EMF-based ammonia gas sensors using a wireless network.
Research
RF Safe Research Library
Jan 1, 2011
This engineering paper proposes a control method for a photo-electromagnetic field (EMF)-based ammonia gas sensor that uses a wireless network and adjusts illumination light intensity. It reports that measurement error is minimized over 3800 ppm ammonia when the concentration corresponds to an optimal illumination…
Fuzzy mobile-robot positioning in intelligent spaces using wireless sensor networks.
Research
RF Safe Research Library
Jan 1, 2011
This engineering study develops and experimentally evaluates a fuzzy-logic method for locating mobile robots in an intelligent space using wireless sensor networks. Localization relies on inter-node range measurements estimated from RF signal strength attenuation, which the authors describe as noisy and unreliable.…
Measurement of creatine kinase reaction rate in human brain using magnetization transfer image-selected in vivo spectroscopy (MT-ISIS) and a volume ³¹P/¹H radiofrequency coil in a clinical 3-T MRI system.
Research
RF Safe Research Library
Jan 1, 2011
This paper describes a new magnetization transfer 31P MRS approach (MT-ISIS) for measuring the creatine kinase forward reaction rate in the human brain using a volume 31P/1H RF coil on a clinical 3-T MRI system. The method aims to reduce acquisition time (30 min), avoid scalp muscle contamination, improve RF…
Correction of main and transmit magnetic field (B0 and B1) inhomogeneity effects in multicomponent-driven equilibrium single-pulse observation of T1 and T2.
Research
RF Safe Research Library
Jan 1, 2011
This methods paper addresses how B0 (main field) and B1 (transmit field) inhomogeneities can bias SPGR and bSSFP steady-state MRI signals used for multicomponent T1/T2 relaxometry and myelin water analysis. It describes using DESPOT1-HIFI to calibrate flip angles and adding a B0-related parameter with multiple…
A rapid and facile synthesis of nanofibrillar polyaniline using microwave radiation.
Research
RF Safe Research Library
Jan 1, 2010
This engineering study describes a microwave-assisted method to synthesize polyaniline (PANI) nanofibers. Reported yields under microwave irradiation were similar to conventional synthesis but achieved in minutes rather than hours. Structural and morphological characterization (FTIR, Raman, SEM, TEM) reportedly…
High-intensity pulsed electric fields processing parameters affecting polyphenoloxidase activity of strawberry juice.
Research
RF Safe Research Library
Jan 1, 2010
This study evaluated high-intensity pulsed electric fields (HIPEF) as a processing method to inactivate polyphenoloxidase (PPO) in strawberry juice. Using response surface methodology at a constant electric field of 35 kV/cm, the authors report strong PPO reductions across tested parameter ranges. Bipolar mode,…
Electron dynamics in inhomogeneous magnetic fields.
Research
RF Safe Research Library
Jan 1, 2010
This paper is a review of two-dimensional electron dynamics in microscopically inhomogeneous magnetic fields, focusing on magnetic potentials varying on scales smaller than the mean free path. It covers early work on localization in random magnetic fields, methods to fabricate magnetic potentials, and drift-diffusion…
Ultrasonic propagation velocity in magnetic and magnetorheological fluids due to an external magnetic field.
Research
RF Safe Research Library
Jan 1, 2010
This engineering-focused study measured ultrasonic propagation velocity in hydrocarbon-based magnetic and magnetorheological fluids under an external magnetic field. The authors report that clustering structures formed in the fluids influence ultrasonic propagation velocity, with observed hysteresis and anisotropy.…
Localizing Broca's area for transcranial magnetic stimulation: Comparison of surface distance measurements and stereotaxic positioning.
Research
RF Safe Research Library
Jan 1, 2009
This methods study evaluated an MRI-based surface distance measurements (SDM) approach for localizing Broca's area for TMS coil placement without external tracking devices. Coil positioning using SDM was compared with an advanced frameless stereotaxic navigation system. The reported mean difference between methods…
A new approach for explanation of specimen rupture under high electric field.
Research
RF Safe Research Library
Jan 1, 2009
This engineering-focused study examines failure of needle-shaped specimens exposed to very high electric fields in field-ion microscopy. The authors report experiments indicating breakdown may be initiated by nanoparticles detached from a point anode. They propose a mechanism in which expanding cathode plasma…
A comparison of conventional and radio frequency defrosting of lean beef meats: Effects on water binding characteristics.
Research
RF Safe Research Library
Jan 1, 2009
This study compared slow conventional air defrosting with fast radio frequency (RF) defrosting/tempering in lean beef (whole, minced, and comminuted) using drip loss, NMR relaxometry, and dielectric spectroscopy. RF thawing was associated with lower drip loss and lower micronutrient loss in drip than air thawing,…
Sham Transcranial Magnetic Stimulation Using Electrical Stimulation of the Scalp.
Research
RF Safe Research Library
Jan 1, 2009
This study describes development and validation of a sham rTMS approach that combines a matched sham coil (for look/sound) with scalp electrical stimulation (for sensation). In back-to-back comparisons, TMS-naïve participants reportedly could not tell active from sham, whereas experienced participants could. The…
Numerical methods for computing the ground state of spin-1 Bose-Einstein condensates in a uniform magnetic field.
Research
RF Safe Research Library
Jan 1, 2008
This paper presents numerical methods to compute ground-state solutions of spin-1 Bose-Einstein condensates in a uniform magnetic field. The approach uses normalized gradient flow with an additional normalization condition and enforces conservation of total mass and magnetization. The authors compare numerical…