Archive

1566 posts

Ultrafast volumetric B1 (+) mapping for improved radiofrequency shimming in 3 tesla body MRI.

Research RF Safe Research Library Jan 1, 2014

This engineering/clinical MRI methods study evaluated ultrafast volumetric DREAM B1+ mapping to refine patient-adaptive RF shimming at 3T. In 20 patients and three volunteers, a multi-slice adaptive RF shimming approach reduced flip-angle deviations and improved B1+ homogeneity compared with central-slice-based…

Non-linear adaptive phenomena which decrease the risk of infection after pre-exposure to radiofrequency radiation.

Research RF Safe Research Library Jan 1, 2014

This animal study examined whether pre-exposure to radiofrequency radiation (from a GSM mobile phone) alters survival after subsequent Escherichia coli infection. The abstract reports higher survival in the group receiving both RF pre-exposure and bacterial challenge than in the group receiving only the bacterial…

An ephaptic transmission model of CA3 pyramidal cells: an investigation into electric field effects.

Research RF Safe Research Library Jan 1, 2014

This paper presents a two-compartment computational model of CA3 pyramidal neurons to investigate how extracellular electric fields influence neuronal behavior via ephaptic transmission. The model is matched to subthreshold experimental responses at rest and used to analyze how DC and sinusoidal fields affect…

Liver lesion conspicuity during real-time MR-guided radiofrequency applicator placement using spoiled gradient echo and balanced steady-state free precession imaging.

Research RF Safe Research Library Jan 1, 2014

This retrospective study evaluated liver lesion conspicuity during real-time MR-guided radiofrequency applicator placement using spoiled GRE and balanced SSFP MRI sequences in a 1.5 T scanner. Lesion detectability categories and contrast-to-noise ratio (CNR) were compared for hepatocellular carcinoma and liver…

Passive tracking of linac clinical flow using radiofrequency identification technology.

Research RF Safe Research Library Jan 1, 2014

This study reports implementation of a passive RFID system to passively track patient flow in a radiation therapy clinic using readers/antennae in linac vault areas. Across 4302 treatment fractions from 144 patients, the system achieved about 70% read reliability and enabled comparison of median in-vault treatment…

A comparative study of radiofrequency assisted versus microdebrider assisted turbinoplasty in cases of inferior turbinate hypertrophy.

Research RF Safe Research Library Jan 1, 2014

This prospective interventional study randomized 60 patients with inferior turbinate hypertrophy to bipolar radiofrequency-assisted versus microdebrider-assisted turbinoplasty (30 per group). Both groups showed significant postoperative symptom improvement through 6 months. Three recurrences were reported at 6 months…

Can mobile phones help control neglected tropical diseases? Experiences from Tanzania.

Research RF Safe Research Library Jan 1, 2014

This qualitative case study (2011) describes a pilot mobile phone-based management information system for neglected tropical disease control in Tanzania, where village health workers used phones with web-based software to capture data at source. The study reports improved routine work efficiency and increased…

Autophagy and enhanced chemosensitivity in experimental pancreatic cancers induced by noninvasive radiofrequency field treatment.

Research RF Safe Research Library Jan 1, 2014

This study tested noninvasive 13.56 MHz radiofrequency electric fields as a treatment adjunct for pancreatic ductal adenocarcinoma in cell lines and mouse xenograft models. The authors report RF exposure caused cytotoxicity in PDAC cells via autophagy (not apoptosis) and that normal pancreatic ductal epithelial cells…

Modification of catalase and MAPK in Vicia faba cultivated in soil with high natural radioactivity and treated with a static magnetic field.

Research RF Safe Research Library Jan 1, 2014

This plant study examined effects of a 30 mT static magnetic field and cultivation in soil with high natural radioactivity on oxidative stress-related markers in Vicia faba. The abstract reports significant changes in catalase and MAPK gene expression in treated plants versus controls. Catalase activity and H2O2…

Effect of radiofrequency microtenotomy on degeneration of tendons: an experimental study on rabbits.

Research RF Safe Research Library Jan 1, 2014

This experimental rabbit study evaluated radiofrequency microtenotomy (Rf-mt) in prostaglandin E1-induced Achilles tendon degeneration. Rf-mt increased vascularity based on histopathology and immunohistochemistry. However, the authors report no significant difference in tendon healing compared with a sham-control…

Effects of ultraviolet irradiation, pulsed electric field, hot water and ethanol vapours treatment on functional properties of mung bean sprouts.

Research RF Safe Research Library Jan 1, 2014

This study examined how pulsed electric field, hot water dip, ethanol vapours, and UV irradiation affected antioxidant-related properties of mung bean sprouts during storage at room and low temperatures. Ethanol vapour-treated sprouts had the highest ascorbic acid, total phenols, and antioxidant activity. Polyphenol…

High-frequency hearing loss among mobile phone users.

Research RF Safe Research Library Jan 1, 2014

This prospective single-blinded study assessed hearing above 8 kHz among prolonged mobile phone users using high-frequency audiometry. Because few non-users were available, the study compared each participant’s dominant (phone-used) ear with the non-dominant ear, with the audiologist blinded to dominance. The authors…

The effect of extremely low frequency pulsed electromagnetic field on in vitro fertilization success rate in N MRI mice.

Research RF Safe Research Library Jan 1, 2014

This randomized comparative animal study tested whether extremely low frequency pulsed electromagnetic field exposure affects IVF success in NMRI mice. Mice in the experimental group were exposed to a 1.3 mT pulsed field at 4 kHz for 5 hours during the IVF process. Although the exposed group showed a higher IVF…

Exposure to extremely low-frequency electromagnetic fields inhibits T-type calcium channels via AA/LTE4 signaling pathway.

Research RF Safe Research Library Jan 1, 2014

This in vitro study examined 50 Hz ELF-EMF effects on human T-type calcium channels expressed in HEK293 cells and on native T-type channels in primary cultured mouse cortical neurons. The authors report that ELF-EMF (0.2 mT) inhibited Cav3.1, Cav3.2, and Cav3.3 channel activity without changing Cav3.2 expression or…

Mitigation of biofouling using electromagnetic fields in tubular heat exchangers-condensers cooled by seawater.

Research RF Safe Research Library Jan 1, 2014

This paper describes an engineering application of electromagnetic field (EMF) treatment to mitigate biofouling in seawater-cooled tubular heat exchanger-condensers. After allowing a biofilm to stabilize, EMF treatment was applied and was reported to precipitate dissolved ions and contribute to partial…

Sensory transduction of weak electromagnetic fields: role of glutamate neurotransmission mediated by NMDA receptors.

Research RF Safe Research Library Jan 1, 2014

This rat EEG study reports that weak electromagnetic fields elicited evoked potentials in awake animals but not under anesthesia that included ketamine. Xylazine anesthesia did not eliminate EMF-evoked potentials, whereas ketamine (an NMDA receptor antagonist) was associated with absence of both EMF-evoked and…

Effects of 900 MHz electromagnetic field emitted by cellular phones on electrocardiograms of guinea pigs.

Research RF Safe Research Library Jan 1, 2014

This animal study examined whether RF-EMF from cellular phones affects electrocardiograms in guinea pigs. Thirty guinea pigs were randomized to control (no exposure) or RF-EMF exposure (890–915 MHz; SAR 0.95 W/kg) for 12 hours per day over 30 days. The study reports no significant effects on ECG findings under these…

Assessment of extremely low frequency magnetic field exposure from GSM mobile phones.

Research RF Safe Research Library Jan 1, 2014

This paper reports extremely low frequency (ELF) magnetic flux density measurements from 47 GSM mobile phones, collected to support exposure classification in the MOBI-KIDS epidemiological study. At 25 mm, maximum resultant magnetic flux density at 217 Hz had a geometric mean of 221 nT, and inclusion of harmonics…

Assessment and comparison of total RF-EMF exposure in femtocell and macrocell base station scenarios.

Research RF Safe Research Library Jan 1, 2014

This study assessed and compared total RF-EMF exposure for a mobile-phone user in an office environment when connected to an indoor femtocell base station versus a conventional macrocell base station. Using a framework that combines near-field and far-field exposure, the authors report a 20–40× reduction in total…

Spatial learning, monoamines and oxidative stress in rats exposed to 900 MHz electromagnetic field in combination with iron overload.

Research RF Safe Research Library Jan 1, 2014

This animal study tested whether 900 MHz EMF exposure, alone or combined with brain iron overload, affects cognition and brain biochemistry in Long-Evans rats. EMF-exposed rats showed impairment in an object exploration task and changes in monoamine content (notably in the hippocampus), while other spatial…

No influence of acute RF exposure (GSM-900, GSM-1800, and UMTS) on mouse retinal ganglion cell responses under constant temperature conditions.

Research RF Safe Research Library Jan 1, 2014

This double-blind in vitro study exposed isolated mouse retinae to GSM-900, GSM-1800, and UMTS RF-EMF at SARs up to 20 W/kg while maintaining constant temperature. Changes in retinal ganglion cell responses to light stimuli were compared before, during, and up to 35 minutes after exposure. The authors report no…

Use of portable exposure meters for comparing mobile phone base station radiation in different types of areas in the cities of Basel and Amsterdam.

Research RF Safe Research Library Jan 1, 2014

This exposure assessment study used portable exposure meters to characterize variability and repeatability of mobile phone base station RF-EMF measurements in urban areas of Basel and Amsterdam. Reported exposure levels varied by area type and city, with downtown/business areas showing higher ranges than residential…

Interference between active implanted medical devices and electromagnetic field emitting devices is rare but real: results of an incidence study in a population of physicians in France.

Research RF Safe Research Library Jan 1, 2014

This cross-sectional incidence survey used a postal questionnaire to assess physician-observed interference incidents between EMF-emitting devices and active implanted medical devices (AIMDs) in France. Among 1,188 participating physicians, 16% reported AIMD failures, typically of moderate severity but sometimes…

The alteration of spontaneous low frequency oscillations caused by acute electromagnetic fields exposure.

Research RF Safe Research Library Jan 1, 2014

This double-blind, randomized, crossover study examined whether 30 minutes of near-field LTE radiofrequency exposure near the right ear alters resting-state brain activity measured by fMRI. The authors report decreased ALFF in multiple temporal and frontal/paracentral regions after real exposure compared with sham,…

A pilot neighborhood study towards establishing a benchmark for reducing electromagnetic field levels within single family residential dwellings.

Research RF Safe Research Library Jan 1, 2014

This pilot study reports EMF field audits in 29 single-family residential dwellings in an urban Toronto neighborhood, measuring RF, power-frequency electric and magnetic fields, and high-frequency voltage transients. The authors frame EMF as an indoor pollutant and note a lack of international consensus on exposure…

← Prev Page 49 / 63 Next →