Investigation of Electric Field-Induced Structural Changes at Fe-Doped SrTiO₃ Anode Interfaces by Second Harmonic Generation.
Research
RF Safe Research Library
Jan 1, 2016
This materials study used optical second harmonic generation to detect electric field-induced structural changes at Pt/Fe-doped SrTiO3 anode interfaces. Reduced crystals showed steadily increasing susceptibility with increasing negative voltage, interpreted as electrostriction-related bond distortions. Oxidized…
Influence of Growth Rate and Magnetic Field on Microstructure and Properties of Directionally Solidified Ag-Cu Eutectic Alloy.
Research
RF Safe Research Library
Jan 1, 2016
This materials study examined how growth rate and an external magnetic field affect microstructure and properties in directionally solidified Ag-Cu eutectic alloys. The lamellar spacing followed the Jackson-Hunt model with a reported constant of 5.8 µm³/s. Increasing magnetic field tilted eutectic growth and…
Gerontechnologies for Older Patients with Heart Failure: What is the Role of Smartphones, Tablets, and Remote Monitoring Devices in Improving Symptom Monitoring and Self-Care Management?
Research
RF Safe Research Library
Jan 1, 2016
This review-style article discusses gerontechnologies—mobile applications on smartphones/tablets and remote monitoring systems—for outpatient symptom monitoring and self-care management in older adults with heart failure. It frames these tools as potentially cost-effective and accessible when designed for older…
Auto-Tuning and Self-Calibration of High-Sensitivity Radio Frequency Interferometers.
Research
RF Safe Research Library
Jan 1, 2016
This engineering paper demonstrates an auto-tuning method for a high-sensitivity RF interferometer using a tunable liquid attenuator controlled by liquid volume. The authors report an effective quality factor up to 1×10 at ~5 GHz and a self-calibration/measurement process from 2 to 7.5 GHz using a methanol-water…
Comparative assessment of monopolar and bipolar radiofrequency surgery of inferior turbinate.
Research
RF Safe Research Library
Jan 1, 2016
This prospective, randomized, single-blind study compared monopolar versus bipolar radiofrequency surgery for inferior turbinate hypertrophy in 71 patients. Over 6 months, long-term symptom outcomes did not significantly differ between groups. Monopolar radiofrequency showed earlier symptom improvement and less…
Efficacy of extremely low-frequency magnetic field in fibromyalgia pain: A pilot study.
Research
RF Safe Research Library
Jan 1, 2016
This pilot randomized study evaluated systemic extremely low-frequency magnetic field (ELF-MF) therapy versus sham in 37 women with fibromyalgia using a crossover sequence. The abstract reports significant short-term reductions in pain and improvements in fibromyalgia-related symptom and function questionnaires…
Research on in vitro release of Isoniazid (INH) super paramagnetic microspheres in different magnetic fields.
Research
RF Safe Research Library
Jan 1, 2016
This in vitro study examined how different external magnetic field conditions affect isoniazid release from superparamagnetic iron oxide microspheres. The abstract reports that magnetic fields accelerated drug release, with faster release in acidic (pH 3) conditions and the fastest completion (2 hours) under an…
The relationship between mobile phone location sensor data and depressive symptom severity.
Research
RF Safe Research Library
Jan 1, 2016
This observational study examined whether passively collected smartphone GPS features relate to depressive symptom severity in 48 college students over 10 weeks. Several mobility features (including location variance, entropy, and circadian movement) were reported to correlate with PHQ-9 scores. Associations were…
Enzymatic debridement after mobile phone explosion: a case report.
Research
RF Safe Research Library
Jan 1, 2016
This case report describes a paediatric burn injury resulting from a mobile phone lithium-ion battery explosion. The patient was treated with selective enzymatic debridement, which the authors note is simple, minimally invasive, and safe. The report concerns an acute thermal injury mechanism rather than EMF exposure.
Radio frequency induced heating of an insulated wire during magnetic resonance imaging.
Research
RF Safe Research Library
Jan 1, 2016
This engineering study investigated RF-induced power deposition near straight insulated leads in an MRI context under different incident electric field profiles. Using 3-D electromagnetic simulations, the authors compared simulation-derived power deposition with implant model predictions. For the setups examined,…
An innovative therapy for peri-implantitis based on radio frequency electric current: numerical simulation results and clinical evidence.
Research
RF Safe Research Library
Jan 1, 2016
This conference paper describes a peri-implantitis therapy using radio frequency electric current and presents numerical simulations alongside referenced clinical evidence. The abstract reports 81% successful treatment across 66 implants in 46 patients. FEM modeling suggests current preferentially concentrates in…
A wearable bluetooth LE sensor for patient monitoring during MRI scans.
Research
RF Safe Research Library
Jan 1, 2016
This engineering paper reports a prototype wearable patient-monitoring device that transmits vital-sign measurements via Bluetooth LE during MRI. Across 7 MRI acquisitions (25 minutes total), the authors report no Bluetooth packet loss, increased PPG noise during MRI, and no effect on temperature/humidity readings.…
Variation of radio frequency induced power deposition due to second surrounding tissue.
Research
RF Safe Research Library
Jan 1, 2016
This engineering study investigated RF-induced power deposition from insulated leads of different lengths positioned near two surrounding tissues. The authors report that both the electromagnetic lead models and the resulting power deposition depended strongly on the electrical properties of both tissues. Using a…
Automated ABO Rh-D blood type detection using smartphone imaging for point-of-care medical diagnostics.
Research
RF Safe Research Library
Jan 1, 2016
This conference paper describes an automated method for ABO and Rh-D blood typing using images captured by low-cost mobile phones of a fabric strip rapid diagnostic test. The approach applies morphological image processing steps including noise reduction, range filtering, and empirically derived heuristics to…
Effects of extremely low frequency electromagnetic fields on in-vitro cellular cultures HeLa and CHO.
Research
RF Safe Research Library
Jan 1, 2016
This in-vitro study examined whether 50 Hz extremely low frequency electromagnetic fields affect proliferation in HeLa and CHO cell cultures. The abstract reports increased proliferation in exposed cells versus controls, with the largest reported increase under repetitive exposure at 2.49 mT (40 minutes every 12…
In-to-out body path loss for wireless radio frequency capsule endoscopy in a human body.
Research
RF Safe Research Library
Jan 1, 2016
This engineering study uses a 3D electromagnetic solver to simulate in-to-out body RF path loss for a wireless capsule endoscopy link. The capsule antenna is tuned for the 402 MHz MICS band while accounting for human body properties. The authors examine how capsule misalignment, rotation, and the human body model…
Evaluation of the electric field in the brain during transcranial direct current stimulation: A sensitivity analysis.
Research
RF Safe Research Library
Jan 1, 2016
This computational study used finite element modeling to estimate the electric field distribution in the brain during tDCS for two electrode montages targeting the left DLPFC. It systematically varied isotropic tissue conductivity profiles to assess sensitivity of predicted E-field magnitude and components in the…
The effect of inter-electrode distance on the electric field distribution during transcutaneous lumbar spinal cord direct current stimulation.
Research
RF Safe Research Library
Jan 1, 2016
This engineering-focused study examined how inter-electrode distance in transcutaneous spinal direct current stimulation (tsDCS) affects electric field distribution in the lumbar and sacral spinal cord. Peak E-field magnitudes occurred in the lumbo-sacral region for all configurations. Larger electrode separations…
Characterization of thrombus stiffening in radio frequency (rf) Mechanical thrombectomy.
Research
RF Safe Research Library
Jan 1, 2016
This engineering-focused conference paper characterizes thrombus stiffening after radio frequency (rf) electric current treatment in the context of intra-arterial mechanical thrombectomy. The abstract reports thrombus stiffness increased by more than eightfold after rf treatment, attributed to increased crosslinking.…
Microwave to near-infrared conversion with a millimeter-scale wireless laser for activating molecular transducers.
Research
RF Safe Research Library
Jan 1, 2016
This conference paper reports an engineering approach to convert wireless microwave power into near-infrared light using a miniaturized, wirelessly powered laser. The device is described as millimeter-scale and capable of being powered through >1 cm of tissue. The abstract focuses on enabling in vivo activation of…
Design, simulation and evaluation of uniform magnetic field systems for head-free eye movement recordings with scleral search coils.
Research
RF Safe Research Library
Jan 1, 2016
This conference paper describes the design and simulation of coil geometries intended to produce a highly uniform magnetic field for scleral search coil eye-movement recordings without restricting head motion. The authors built a large (2.2 m per side) coil frame and compared measured magnetic flux density to…
Improving resolution of robotic capsule locomotion using dynamic electromagnetic field.
Research
RF Safe Research Library
Jan 1, 2016
This engineering conference paper describes a method for controlling the locomotion of swallowable wireless capsule endoscopy devices using a dynamic magnetic field generated by external coils. A permanent magnet embedded in the capsule is manipulated by adjusting external field strengths to maintain equilibrium for…
[The influence of alternating magnetic field on in vitro litholysis of uroliths in blemaren water solutions].
Research
RF Safe Research Library
Jan 1, 2016
This in vitro study examined whether exposing Blemaren water solutions (pH 6.15) to a 2 Hz alternating magnetic field for one hour changes their ability to dissolve uroliths. The authors report higher dissolution efficiency (about 1.922d7) in pre-exposed solutions compared with non-exposed controls. They also report…
[Genic and non-genic regulation of low frequence pulsed electromagnetic fields on osteoblasts differentiation].
Research
RF Safe Research Library
Jan 1, 2016
This in vitro study exposed rat calvarial osteoblasts to 50 Hz, 0.6 mT pulsed electromagnetic fields for 1.5 hours and measured early differentiation-related markers over 0–12 hours. The abstract reports increased ALP activity at 3 hours and time-dependent changes in ALP, Runx2, and OSX transcription and Runx2/OSX…
[Effects of 1.8 mT sinusoidal alternating electromagnetic fields of different frequencies on bone biomechanics of young rats].
Research
RF Safe Research Library
Jan 1, 2016
This randomized animal experiment exposed 32 young female rats to 1.8 mT sinusoidal alternating electromagnetic fields at 10, 25, or 40 Hz for 90 minutes per day. The 10 Hz and 40 Hz groups had higher BMD and improved femur and lumbar vertebra biomechanical properties compared with controls, and micro-CT suggested…