Increased blood oxygen level-dependent (BOLD) sensitivity in the mouse somatosensory cortex during electrical forepaw stimulation using a cryogenic radiofrequency probe.
Research
RF Safe Research Library
Jan 1, 2011
This engineering-focused mouse fMRI study evaluated a 400-MHz cryogenic RF probe (CryoProbe) versus a conventional room-temperature surface coil during electrical forepaw stimulation. The CryoProbe increased image SNR and temporal SNR and reduced temporal noise compared with the room-temperature coil. The authors…
Impact of a static magnetic field on the electricity production of Shewanella-inoculated microbial fuel cells.
Research
RF Safe Research Library
Jan 1, 2011
This study investigated how exposure to a static magnetic field affects electricity production in Shewanella-inoculated microbial fuel cells across different reactor configurations. A 100 mT field was reported to increase maximum voltage and the effect was described as immediate and reversible, with possible adverse…
Transient and steady-state magnetic fields induce increased fluorodeoxyglucose uptake in the rat hindbrain.
Research
RF Safe Research Library
Jan 1, 2011
This animal PET study examined whether a weak 60-Hz magnetic field alters brain glucose utilization in rats. The abstract reports increased FDG uptake in hindbrain voxels when a 2.5-G field was oriented orthogonally to the sagittal plane, but not when field direction varied randomly. Distinct activation effects were…
Effects of low frequency electromagnetic fields on the chondrogenic differentiation of human mesenchymal stem cells.
Research
RF Safe Research Library
Jan 1, 2011
This in vitro study examined whether extremely low-frequency magnetic fields affect chondrogenic differentiation of human mesenchymal stem cells in pellet culture. Cells exposed for 3 weeks to a homogeneous sinusoidal 5 mT magnetic field showed increased collagen type II expression (significant at passage 6) and…
Effect of external normal and parallel electric fields on 180° ferroelectric domain walls in PbTiO₃.
Research
RF Safe Research Library
Jan 1, 2011
This modeling study applies uniform electric fields parallel and normal to 180° ferroelectric domain walls in PbTiO3 and computes equilibrium structures using anharmonic lattice statics. The authors report that electric fields can substantially increase domain wall thickness and identify a critical field Ec above…
Orientation and Dynamics of ZnO Nanorod Liquid Crystals in Electric Fields.
Research
RF Safe Research Library
Jan 1, 2010
This materials study reports that ZnO nanorod polymer hybrids can form liquid-crystalline phases and exhibit orientation switching under an applied AC electric field. The orientation reportedly changes from planar to homeotropic, analogous to switching in low-molecular liquid crystals. Dielectric measurements and…
Disintegration efficiency of pulsed electric field induced effects on onion (Allium cepa L.) tissues as a function of pulse protocol and determination of cell integrity by ¹H-NMR relaxometry.
Research
RF Safe Research Library
Jan 1, 2010
This experimental study examined how pulsed electric field (PEF) processing parameters affect cell membrane rupture in onion tissue disks, using ion leakage as the primary integrity measure. Disintegration efficiency increased with field strength up to 500 V/cm and varied with pulse width, pulse number, and…
Spin current pumped by a rotating magnetic field in zigzag graphene nanoribbons.
Research
RF Safe Research Library
Jan 1, 2010
This theoretical study models electron spin resonance and spin/charge pumping in zigzag graphene nanoribbons driven by a transverse rotating magnetic field without applied bias. It reports that pumped spin current density increases with ribbon size and rotating-field intensity, and that even-chain ribbons can also…
Effects of magnetic field and pressure on the intermediate valence state of YbPd.
Research
RF Safe Research Library
Jan 1, 2010
This condensed-matter physics study examined how high magnetic fields and pressure affect magnetization, transport, and thermodynamic properties of the intermediate-valence compound YbPd. The authors report that the Yb valence state and two first-order transitions are stable up to 55 T, while increasing pressure…
Magnetodeformation effects and the swelling of ferrogels in a uniform magnetic field.
Research
RF Safe Research Library
Jan 1, 2010
This laboratory/materials study examined deformation and swelling of magnetic field sensitive polymer gels (ferrogels) in a static, uniform magnetic field. The authors report that gels with randomly distributed magnetic particles exhibited weak magnetodeformation, whereas gels with aligned particles showed no…
Pressure and magnetic field dependence of valence and magnetic transitions in EuPtP.
Research
RF Safe Research Library
Jan 1, 2010
This laboratory study investigates how magnetic field and pressure affect valence and magnetic transitions in the compound EuPtP. High-field analysis suggests a mixed valence state at low temperature and discontinuous changes in Eu2+ fraction at two transition temperatures. Pressure increases the transition…
Electric field gradients in (111)In-doped (Hf/Zr)3Al2 and (Hf/Zr)4Al3 mixed compounds: ab initio calculations, perturbed angular correlation measurements and site preference.
Research
RF Safe Research Library
Jan 1, 2010
This materials-physics study investigated quadrupolar hyperfine interactions of (111)In→(111)Cd probes in polycrystalline Zr4Al3 and Hf4Al3 containing minority (Zr/Hf)3Al2 phases. The authors observed a strong preference of (111)In solutes for the minority (Zr/Hf)3Al2 phases. Ab initio EFG calculations were used to…
Electric fields on quasiperiodic potentials.
Research
RF Safe Research Library
Jan 1, 2010
This theoretical condensed-matter study examines how an electric field affects the electronic spectrum and localization in quasiperiodic chains modeled with Harper and Fibonacci potentials. It reports localized ladder spectra under strong fields and smoothing with linearly decreasing gaps under weak fields. When…
Spin polarization induced by in-plane electric and magnetic fields in two-dimensional heavy-hole systems.
Research
RF Safe Research Library
Jan 1, 2010
This theoretical study uses a nonequilibrium Green function approach to analyze current-induced spin polarization in a two-dimensional heavy-hole system with cubic Rashba spin-orbit coupling under in-plane electric and magnetic fields. The authors report monotonic decreases in longitudinal conductivity with…
Surface superconducting states in a yttrium hexaboride single crystal in a tilted magnetic field.
Research
RF Safe Research Library
Jan 1, 2010
This experimental study examined nucleation of superconductivity at the surface of a single-crystal yttrium hexaboride (YB6) in a tilted dc magnetic field. The authors measured Hc3 on each side of the sample as a function of the angle between the field and the surface. They report Hc3/Hc2 ≈ 1.28 for a perpendicular…
Electric field induced structuring in clay-oil suspensions: new insights from WAXS, SEM, leak current, dielectric permittivity, and rheometry.
Research
RF Safe Research Library
Jan 1, 2010
This laboratory/engineering study examined electric-field-induced structuring in clay-oil suspensions using WAXS, SEM, rheometry, and electrical measurements. Particle orientation was quantified via an orientational order parameter derived from diffraction peak azimuthal changes, and chain versus column formation was…
Ultrasonic propagation velocity in magnetic and magnetorheological fluids due to an external magnetic field.
Research
RF Safe Research Library
Jan 1, 2010
This engineering-focused study measured ultrasonic propagation velocity in hydrocarbon-based magnetic and magnetorheological fluids under an external magnetic field. The authors report that clustering structures formed in the fluids influence ultrasonic propagation velocity, with observed hysteresis and anisotropy.…
The influence of temperature and electric field history on the conductivity of the charge density wave system o-TaS3.
Research
RF Safe Research Library
Jan 1, 2010
This laboratory study examined how temperature and prior electric-field exposure affect low-field conductivity in the charge density wave material o-TaS3. Conductivity differed between cooling and heating below the CDW transition, and applying increasing electric fields drove the system toward a stable,…
[Treatment of benign prostatic hyperplasia by radiofrequency (TUNA): a monocentric study of 28 cases treated in ambulatory surgery].
Research
RF Safe Research Library
Jan 1, 2009
This monocentric study evaluated outpatient feasibility and outcomes of radiofrequency transurethral needle ablation (TUNA) for benign prostatic hyperplasia in patients who did not respond to medical therapy. In the outpatient subgroup, urinary symptom scores, quality of life, flow measures, and residual urine…
Localizing Broca's area for transcranial magnetic stimulation: Comparison of surface distance measurements and stereotaxic positioning.
Research
RF Safe Research Library
Jan 1, 2009
This methods study evaluated an MRI-based surface distance measurements (SDM) approach for localizing Broca's area for TMS coil placement without external tracking devices. Coil positioning using SDM was compared with an advanced frameless stereotaxic navigation system. The reported mean difference between methods…
Cyanide orientational ordering and copper electric field gradients in CuCN.N2H4.
Research
RF Safe Research Library
Jan 1, 2009
This study reports solid-state NMR (13C and 15N MAS) measurements on CuCN·N2H4 to extract copper quadrupole coupling constants and characterize cyanide ordering. Ab initio calculations were used to determine electric field gradient and chemical shielding tensor orientations needed for spectral analysis. The authors…
The use of a standard radiofrequency energy delivery system to facilitate transseptal puncture.
Research
RF Safe Research Library
Jan 1, 2009
This paper describes a procedural technique for transseptal puncture that uses brief pulses of radiofrequency energy delivered from a standard electrosurgical cautery generator through the needle tip. The approach is presented as a way to facilitate septal traversal when tissue is elastic, aneurysmal, or thickened,…
A new approach for explanation of specimen rupture under high electric field.
Research
RF Safe Research Library
Jan 1, 2009
This engineering-focused study examines failure of needle-shaped specimens exposed to very high electric fields in field-ion microscopy. The authors report experiments indicating breakdown may be initiated by nanoparticles detached from a point anode. They propose a mechanism in which expanding cathode plasma…
Spatial and Temporal Variations of a Screening Current Induced Magnetic Field in a Double-Pancake HTS Insert of an LTS/HTS NMR Magnet.
Research
RF Safe Research Library
Jan 1, 2009
This engineering study measures and simulates screening current induced magnetic fields (SCF) in a Bi2223-tape HTS insert used in an LTS/HTS NMR magnet at 77 K. SCF was induced by the insert self-field, an external 5-T background magnet, and their combination, and axial field distributions and temporal variations…
Dominant mobility modulation by the electric field effect at the LaAlO3/SrTiO3 interface.
Research
RF Safe Research Library
Jan 1, 2009
This Physical Review Letters paper reports magnetotransport measurements on a gated LaAlO3/SrTiO3 interface to assess the main effect of an applied gate electric field. The authors find that mobility changes dominate over sheet carrier density changes (mobility variation reported as nearly fivefold larger). They also…