Archive

817 posts

Showing results for: PER

Biological proton pumping in an oscillating electric field.

Research RF Safe Research Library Jan 1, 2009

This paper models biological proton pumping in cytochrome c oxidase under an applied oscillating electric field. The authors report that proton pumping efficiency and steady-state electronic currents vary significantly with the field’s frequency and amplitude. A spectral analysis is described as supporting dominant…

Ising spin-glass transition in a magnetic field outside the limit of validity of mean-field theory.

Research RF Safe Research Library Jan 1, 2009

This paper studies the spin-glass transition in a magnetic field using a diluted one-dimensional long-range Ising model with distance-dependent bond probability. The authors report evidence for a spin-glass transition in a magnetic field both within and beyond the mean-field regime. They also report such evidence for…

Extraordinary magnetic field enhancement with metallic nanowire: role of surface impedance in Babinet's principle for sub-skin-depth regime.

Research RF Safe Research Library Jan 1, 2009

This paper proposes metallic nanowires as complementary structures to metallic nanogaps for enhancing magnetic fields. It reports magnetic field enhancement up to a factor of 300 and presents a surface-impedance-based analytic theory that is numerically confirmed. The authors also report that, in the sub-skin-depth…

Electric field switching of the magnetic anisotropy of a ferromagnetic layer exchange coupled to the multiferroic compound BiFeO3.

Research RF Safe Research Library Jan 1, 2009

This paper reports electric-field control of magnetic anisotropy in a Permalloy layer exchange-coupled to a multiferroic BiFeO3 single crystal. The anisotropy is described as arising from magnetic coupling to canted spins in BiFeO3’s cycloidal antiferromagnetic structure. An electric field-induced polarization change…

Magnetic field delocalization and flux inversion in fractional vortices in two-component superconductors.

Research RF Safe Research Library Jan 1, 2009

This theoretical paper analyzes vortex solutions in two-component superconductors within a U(1) x U(1) Ginzburg-Landau framework. It reports that exponentially screened magnetic fields are only found in special cases, while most parameter choices yield delocalized magnetic fields with slowly decaying tails. It also…

Dominant mobility modulation by the electric field effect at the LaAlO3/SrTiO3 interface.

Research RF Safe Research Library Jan 1, 2009

This Physical Review Letters paper reports magnetotransport measurements on a gated LaAlO3/SrTiO3 interface to assess the main effect of an applied gate electric field. The authors find that mobility changes dominate over sheet carrier density changes (mobility variation reported as nearly fivefold larger). They also…

Microscopic dynamics of the orientation of a hydrated nanoparticle in an electric field.

Research RF Safe Research Library Jan 1, 2009

This paper uses atomistic simulations to examine how a nonpolar nanoparticle suspended in water reorients under an applied electric field. The authors report that molecular-level effects increase the torque relative to continuum estimates and substantially speed up reorientation above a stated field threshold. The…

Quasiparticles of spatially anisotropic triangular antiferromagnets in a magnetic field.

Research RF Safe Research Library Jan 1, 2009

This theoretical/physics study investigates spectral properties of a spin-1/2 Heisenberg antiferromagnet on an anisotropic triangular lattice in a magnetic field. It reports that interchain interactions in a magnetic field generate dominant modes that behave as quasiparticles, featuring anomalous incommensurate…

Mitomycin C-associated radiofrequency microelectrocautery used in myringotomy in an animal model.

Research RF Safe Research Library Jan 1, 2009

This experimental animal study compared tympanic membrane closure time after myringotomy performed by microknife versus radiofrequency microcautery, with and without mitomycin C. Radiofrequency myringotomy differed significantly from knife myringotomy, and the 0.7 mm radiofrequency tip combined with mitomycin C was…

Theory for nanoparticle retention time in the helical channel of quadrupole magnetic field-flow fractionation.

Research RF Safe Research Library Jan 1, 2009

This paper presents a theoretical treatment of nanoparticle retention in quadrupole magnetic field-flow fractionation (QMgFFF) using a helical separation channel. It defines the retention ratio as the ratio of transit times for non-retained versus retained material. Equations are derived for angular and longitudinal…

Sham Transcranial Magnetic Stimulation Using Electrical Stimulation of the Scalp.

Research RF Safe Research Library Jan 1, 2009

This study describes development and validation of a sham rTMS approach that combines a matched sham coil (for look/sound) with scalp electrical stimulation (for sensation). In back-to-back comparisons, TMS-naïve participants reportedly could not tell active from sham, whereas experienced participants could. The…

[Effects of 50 Hz sinusoidal magnetic field on Ca2+ release channel ryanodine receptor of sarcoplasmic reticulum vesicles].

Research RF Safe Research Library Jan 1, 2009

This in vitro study examined whether a 50 Hz sinusoidal magnetic field affects the sarcoplasmic reticulum calcium release channel RyR1. A 0.4 mT exposure for 30 minutes increased SR Ca2+ release rate and [(3)H]-ryanodine binding under NADH/NAD+ conditions. The authors also report increased NADH oxidation and…

[A aquaporin 4 expression and effects in rat hippocampus after microwave radiation].

Research RF Safe Research Library Jan 1, 2009

This rat study examined hippocampal aquaporin 4 (AQP4) expression after microwave exposure at 10, 30, or 100 mW/cm^2. The authors report increased AQP4 protein and gene expression after exposure, with recovery at lower power density but more persistent elevation at higher power density. They conclude that increased…

Survey of ownership and use of mobile phones among medical science students in Yazd.

Research RF Safe Research Library Jan 1, 2009

This cross-sectional survey assessed mobile phone ownership and use patterns among 309 medical science students in Yazd using a self-administered questionnaire. The abstract reports descriptive statistics on daily talking time, music listening, texting, and common locations of phone use. While the paper references…

Static magnetic field therapy: a critical review of treatment parameters.

Research RF Safe Research Library Jan 1, 2009

This critical review summarizes human research on static magnetic field (SMF) therapy delivered by permanent magnets attached to the skin and evaluates how well studies report SMF dosage and treatment parameters. Across 56 included studies, many did not report essential SMF characteristics (e.g., magnet dimensions,…

Apparent violation of the Wiedemann-Franz law near a magnetic field tuned metal-antiferromagnetic quantum critical point.

Research RF Safe Research Library Jan 1, 2008

This paper reports calculations of interlayer electrical and thermal resistivity in a layered metal assuming Fermi-liquid quasiparticles inelastically scattered by two-dimensional antiferromagnetic spin fluctuations. The model yields linear-in-temperature behavior over a broad range and suggests that extrapolations…

Silicon-on-insulator-based radio frequency single-electron transistors operating at temperatures above 4.2 K.

Research RF Safe Research Library Jan 1, 2008

This engineering study demonstrates a silicon-on-insulator (SOI) radio-frequency single-electron transistor (RF-SET) operating at temperatures above 4.2 K. The device was optimized to address high resistance in SOI SETs and showed stable transport characteristics after repeated thermal cycling. RF-SET operation was…

The effect of postoperative immobilization on the healing of radiofrequency heat probe modified tissue: assessment of tissue length, stiffness, and morphology.

Research RF Safe Research Library Jan 1, 2008

This animal study examined how postoperative immobilization affects healing after radiofrequency heat probe shrinkage in rabbit patellar tendons. Tendon length increased across all groups by 8 weeks, but 4 weeks of immobilization resulted in less elongation than free activity. Immobilized groups had reduced…

Health hazards of mobile phones: an Indian perspective.

Research RF Safe Research Library Jan 1, 2008

This review-style article provides an overview of mobile phone radiation exposure in India and discusses potential health hazards in terms of thermal and non-thermal effects. It states that usage behaviors such as longer call duration and predominantly one-sided use are described as key risks increasing the…

Numerical methods for computing the ground state of spin-1 Bose-Einstein condensates in a uniform magnetic field.

Research RF Safe Research Library Jan 1, 2008

This paper presents numerical methods to compute ground-state solutions of spin-1 Bose-Einstein condensates in a uniform magnetic field. The approach uses normalized gradient flow with an additional normalization condition and enforces conservation of total mass and magnetization. The authors compare numerical…

Surface-induced nonlinearities of liquid crystals driven by an electric field.

Research RF Safe Research Library Jan 1, 2008

This experimental physics study examines how a static electric field affects the optical nonlinearity of methyl-red doped nematic liquid crystals. The authors report that low voltages below the Fredericks transition threshold can change the optical nonlinearity by orders of magnitude. They state that the data fit a…

Aggregation of magnetic holes in a rotating magnetic field.

Research RF Safe Research Library Jan 1, 2008

This laboratory study experimentally examined aggregation of nonmagnetic particles in a magnetic fluid layer under a rotating magnetic field. Particles formed two-dimensional clusters that repeatedly aggregated into larger clusters, producing a broad distribution of cluster sizes. The dynamics were described as…

Effect of temperature (-5 to 130 degrees C) and fiber direction on the dielectric properties of beef Semitendinosus at radio frequency and microwave frequencies.

Research RF Safe Research Library Jan 1, 2008

This study measured dielectric properties of beef Semitendinosus across 27, 915, and 1800 MHz and temperatures from -5 to 130 °C using an open-ended coaxial probe. The results indicate that frequency, temperature, and muscle fiber orientation influence dielectric constant, dielectric loss, and calculated penetration…

The effect of MRET polymer compound on SAR values of RF phones.

Research RF Safe Research Library Jan 1, 2008

This article describes a hypothesis and experimental testing of an MRET polymer compound applied to RF phones. It reports increased dielectric permittivity in water-based solutions and reduced SAR values in a tissue-simulating phantom head. It also reports no significant change in air measurements of phone signals,…

Influence of mashed potato dielectric properties and circulating water electric conductivity on radio frequency heating at 27 MHz.

Research RF Safe Research Library Jan 1, 2008

This engineering study used experiments, computer simulations, and simplified analytical calculations to examine how mashed potato dielectric properties and circulating water electrical conductivity affect RF heating at 27 MHz. The authors report that higher circulating water conductivity and higher salt content in…

← Prev Page 31 / 33 Next →