Archive

742 posts

Showing results for: SES

Genetic damage in mammalian somatic cells exposed to radiofrequency radiation: a meta-analysis of data from 63 publications (1990-2005)

Research RF Safe Research Library Jan 1, 2008

A meta-analysis of 63 publications assessed whether radiofrequency (RF) radiation exposure is associated with genetic damage in mammalian somatic cells using multiple genotoxicity endpoints. Overall differences between RF-exposed and control conditions were reported as small, though statistically significant…

Head-to-head comparison of coronary plaque evaluation between multislice computed tomography and intravascular ultrasound radiofrequency data analysis.

Research RF Safe Research Library Jan 1, 2008

This study compared coronary plaque assessment by 64-slice multislice computed tomography (MSCT) with virtual histology intravascular ultrasound (VH IVUS) in 50 patients. The Agatston score on MSCT correlated moderately with calcium volume measured by VH IVUS, and MSCT plaque categories broadly reflected differences…

[Effect of 1.8 GHz radiofrequency electromagnetic fields on gene expression of rat neurons].

Research RF Safe Research Library Jan 1, 2008

This in vitro study exposed primary cultured rat neurons to 1.8 GHz RF-EMF at an average SAR of 2 W/kg and assessed gene expression changes. The authors report multiple differentially expressed genes after 24 h intermittent exposure and confirm exposure-dependent changes in Egr-1, Mbp, and Plp by semi-quantitative…

[Influence of electromagnetic radiation on raf kinase inhibitor protein and its related proteins of hippocampus].

Research RF Safe Research Library Jan 1, 2008

This rat study examined hippocampal RKIP and related markers after exposure to high power microwaves (X-band and S-band) or an electromagnetic pulse. RKIP protein decreased at 6 hours post-exposure, with recovery by 1 day in the EMP group but more prolonged decreases (up to ~7 days) in the microwave groups.…

The effect of postoperative immobilization on the healing of radiofrequency heat probe modified tissue: assessment of tissue length, stiffness, and morphology.

Research RF Safe Research Library Jan 1, 2008

This animal study examined how postoperative immobilization affects healing after radiofrequency heat probe shrinkage in rabbit patellar tendons. Tendon length increased across all groups by 8 weeks, but 4 weeks of immobilization resulted in less elongation than free activity. Immobilized groups had reduced…

Health hazards of mobile phones: an Indian perspective.

Research RF Safe Research Library Jan 1, 2008

This review-style article provides an overview of mobile phone radiation exposure in India and discusses potential health hazards in terms of thermal and non-thermal effects. It states that usage behaviors such as longer call duration and predominantly one-sided use are described as key risks increasing the…

Numerical methods for computing the ground state of spin-1 Bose-Einstein condensates in a uniform magnetic field.

Research RF Safe Research Library Jan 1, 2008

This paper presents numerical methods to compute ground-state solutions of spin-1 Bose-Einstein condensates in a uniform magnetic field. The approach uses normalized gradient flow with an additional normalization condition and enforces conservation of total mass and magnetization. The authors compare numerical…

Influence of mashed potato dielectric properties and circulating water electric conductivity on radio frequency heating at 27 MHz.

Research RF Safe Research Library Jan 1, 2008

This engineering study used experiments, computer simulations, and simplified analytical calculations to examine how mashed potato dielectric properties and circulating water electrical conductivity affect RF heating at 27 MHz. The authors report that higher circulating water conductivity and higher salt content in…

Greyscale intravascular ultrasound and IVUS-radiofrequency tissue characterisation to improve understanding of the mechanisms of coronary stent thrombosis in drug-eluting stents.

Research RF Safe Research Library Jan 1, 2008

This review describes proposed mechanical causes of drug-eluting stent thrombosis and notes that many are identifiable by greyscale intravascular ultrasound (IVUS). It highlights that evidence linking specific IVUS findings to stent thrombosis remains uncertain because relatively few stent thrombosis cases have been…

Improvement in magnetic field immunity of externally-coupled transcutaneous energy transmission system for a totally implantable artificial heart.

Research RF Safe Research Library Jan 1, 2008

This engineering study addresses interference between induction-heating cookers and an externally coupled transcutaneous energy transmission system for a totally implantable artificial heart. The authors report that magnetic flux from an IH cooker can couple into the TET transformer and affect system performance. A…

[Microstrip antenna design and system research of radio frequency identification temperature sensor].

Research RF Safe Research Library Jan 1, 2008

This engineering paper introduces an RFID sensor network concept integrating RFID with wireless sensor networks and emphasizes the role of antennas. It discusses coil, dipole, and microstrip antennas and reports designing a microstrip antenna for a wireless temperature monitoring and control system. Measurements are…

Minimal-SAR RF pulse optimization for parallel transmission in MRI.

Research RF Safe Research Library Jan 1, 2008

This engineering study presents an optimization framework to design RF pulses for parallel transmission MRI with the goal of minimizing SAR. Using computer simulations of a 4-channel system, the authors report significant SAR reduction while maintaining excitation pattern quality and without increasing pulse…

Coil design considerations for deep-brain transcranial magnetic stimulation (dTMS).

Research RF Safe Research Library Jan 1, 2008

This engineering-focused conference paper proposes figures of merit to evaluate deep-brain transcranial magnetic stimulation (dTMS) coil designs, focusing on depth penetration, scalp stimulation, focality, and energy. It analyzes circular crown and C-core coils and reports reduced electric-field attenuation with…

New functions developed for ICU/CCU remote monitoring system using a 3G mobile phone and evaluations of the system.

Research RF Safe Research Library Jan 1, 2008

This conference paper describes development of new functions for an ICU/CCU remote monitoring system that uses a 3G mobile phone. The authors state that evaluations were performed on several different mobile phones and suggest the system has accuracy and real-time performance suitable for hospital adoption. The…

Chemotherapy side-effect management using mobile phones.

Research RF Safe Research Library Jan 1, 2008

This conference paper describes a mobile-phone telemedicine system for managing chemotherapy side-effects at home using symptom diaries and automated alerts to nurses. Six patients used the system for two cycles of oral chemotherapy. The abstract reports two instances where moderate symptoms deteriorated to more…

Electromagnetic interference to infusion pumps. Update2008 from GSM mobile phones.

Research RF Safe Research Library Jan 1, 2008

This engineering study updates a prior (2005) survey on electromagnetic interference (EMI) affecting infusion pumps and extends testing to DECT phones and WiFi terminals. It reports a reduced failure rate for GSM phone exposure compared with 2005 (58% to 30%). The authors report that WiFi and DECT did not pose a real…

Single access point localisation for wearable wireless sensors.

Research RF Safe Research Library Jan 1, 2008

This engineering conference paper describes a single access point method for localizing a subject using RF signals from wearable wireless sensors. The approach combines RSSI and LQI measurements from one basestation and applies filtering. The abstract reports that accuracy can approach that of multi-basestation…

Radiofrequency dosimetry in subjects implanted with metallic straight wires: a numerical study.

Research RF Safe Research Library Jan 1, 2008

This numerical FDTD study modeled RF exposure at 900 and 1800 MHz in tissue containing thin metallic straight wire implants. The model indicates that the wire can substantially increase local SAR, creating high SAR gradients. Despite this, the authors report that exposures below current safe levels resulted in…

Position-independent chemical quantitation with passive 13.56-MHz radio frequency identification (RFID) sensors.

Research RF Safe Research Library Jan 1, 2008

This engineering study evaluates whether passive 13.56-MHz RFID-based chemical sensors can quantify analytes reliably despite repositioning errors between the sensor and pickup coil. Using simultaneous measurement of multiple complex-impedance parameters and multivariate statistical analysis, the authors report…

A benzene-core trinuclear GdIII complex: towards the optimization of relaxivity for MRI contrast agent applications at high magnetic field.

Research RF Safe Research Library Jan 1, 2008

This chemistry/engineering study reports the synthesis and NMR/MRI-relevant characterization of a trinuclear Gd(III) chelate intended for high-field MRI contrast applications. Using 17O NMR and proton relaxivity across multiple fields and temperatures, the authors infer bishydration, quantify water exchange and…

Effects of electromagnetic field produced by mobile phones on the oxidant and antioxidant status of rats.

Research RF Safe Research Library Jan 1, 2007

This rat study examined whether EMR from GSM mobile phones affects oxidant/antioxidant status. Compared with controls, exposed rats had lower plasma antioxidant vitamins (C, E, A), reduced glutathione, and lower CAT and SOD activities. The acute exposure condition was reported to produce larger decreases than the…

Aerodynamically assisted bio-jets: the development of a novel and direct non-electric field-driven methodology for engineering living organisms.

Research RF Safe Research Library Jan 1, 2007

This paper describes an aerodynamically assisted bio-jetting technique that processes living cells/organisms using differential pressure rather than an electric field. The authors report an operational window for stable jetting and near-monodispersed cell-bearing droplets. Cell viability after jetting was evaluated…

Magnetic field exposure in a nondestructive testing operation.

Research RF Safe Research Library Jan 1, 2007

This exposure assessment measured peak magnetic fields during magnetic particle inspection, a nondestructive testing method that uses electromagnetism. Ninety-five peak measurements taken while inspecting 8 turbine engine shafts ranged from

[Operational aspects of risk perception in the electromagnetic fields exposition].

Research RF Safe Research Library Jan 1, 2007

This study reports on symptomatology and risk perception among 45 people living near power-lines in the Benevento area. Although measured electric and magnetic fields were described as being within the normal range, participants reported symptoms mainly in subjective and behavioural domains. The authors argue that…

[Evaluation of the occupational risk related to exposure to electromagnetic fields according to the EC Directive 2004/40 EC: exposure during pregnancy].

Research RF Safe Research Library Jan 1, 2007

This article addresses occupational EMF exposure during pregnancy in the context of EU Directive 2004/40/EC, emphasizing the need for workplace risk evaluation. It notes that research evidence on pregnancy risks from occupational EMF exposure is currently scarce and inconclusive. The authors also report insufficient…

← Prev Page 29 / 30 Next →