Archive

817 posts

Showing results for: PER

Effects of radiofrequency radiation exposure on blood-brain barrier permeability in male and female rats

Research RF Safe Research Library Jan 1, 2011

This rat study tested whether acute exposure to 0.9 and 1.8 GHz continuous-wave radiofrequency radiation alters blood-brain barrier permeability. Using Evans-blue/albumin as a tracer, the authors report no BBB leakage in exposed female rats but a significant increase in albumin in exposed male rat brains versus sham.…

Comparison between different thickness umbrella-shaped expandable radiofrequency electrodes (SuperSlim and CoAccess): Experimental and clinical study.

Research RF Safe Research Library Jan 1, 2011

This experimental and clinical study compared two umbrella-shaped expandable radiofrequency ablation electrodes (SuperSlim vs CoAccess) across different ablation algorithms. In ex vivo bovine liver, CoAccess generally produced larger ablation areas and required longer ablation times than SuperSlim, with no…

Effects of chain stiffness and salt concentration on responses of polyelectrolyte brushes under external electric field.

Research RF Safe Research Library Jan 1, 2011

This paper reports molecular dynamics simulations of polyelectrolyte brushes subjected to external electric fields, focusing on how chain stiffness and salt concentration affect responses. The simulations suggest higher salt concentrations strengthen an induced opposing field from ion redistribution, which resists…

Influences of electric field on living cells in a charged water-in-oil droplet under electrophoretic actuation.

Research RF Safe Research Library Jan 1, 2011

This experimental study examined whether strong electric fields used for electrophoretic actuation of charged water-in-oil droplets affect living cells inside the droplets. Using Trypan blue and cell growth tests across electric field strengths of 1–3 kV/cm and varying actuation times, the authors report no…

A handheld preconcentrator for the rapid collection of cancerous cells using dielectrophoresis generated by circular microelectrodes in stepping electric fields.

Research RF Safe Research Library Jan 1, 2011

This engineering study describes a handheld microfluidic preconcentrator that uses dielectrophoresis generated by circular microelectrodes with a stepping electric field. Numerical simulations were used to illustrate the electric-field concept. In experiments, HeLa cells were reportedly preconcentrated within 160…

Correction of microcirculatory disturbances with terahertz electromagnetic radiation at nitric oxide frequencies in albino rats under conditions of acute stress.

Research RF Safe Research Library Jan 1, 2011

This animal study reports that terahertz electromagnetic irradiation at nitric oxide (NO)-related frequencies (150.176150.664 GHz) corrected peripheral microcirculatory disturbances in albino rats experiencing acute immobilization stress. The abstract frames the effect as a correction of stress-related peripheral…

Experimental study of relationship between biological hazards of low-dose radiofrequency exposure and energy flow density in Spirostomum ambiguum infusoria exposed at a mobile connection frequency (1 GHz).

Research RF Safe Research Library Jan 1, 2011

This experimental study exposed Spirostomum ambiguum infusoria to 1 GHz radiofrequency fields at 5 and 50 μW/cm² and reports reduced motor activity. The effect was described as threshold-like, appearing after a certain exposure duration and not increasing with longer exposure. The authors report different 'safe'…

Hematological and toxicogenomic effects of ferromagnetic screening of natural electromagnetic fields.

Research RF Safe Research Library Jan 1, 2011

This rat study tracked hematological and toxicogenomic aftereffects over 45 days following 2 days of ferromagnetic screening of natural electromagnetic fields. The authors report leukopenia at day 14 and increases in genomic instability markers (aneuploidy and polyploidy) in male leukocytes persisting after screening…

Milk processed by pulsed electric fields: evaluation of microbial quality, physicochemical characteristics, and selected nutrients at different storage conditions.

Research RF Safe Research Library Jan 1, 2011

This study evaluated pulsed electric fields (PEF) as a pasteurization method for raw skim and whole milk across multiple treatment intensities and storage conditions. The abstract reports only minor changes in physicochemical properties and small decreases in some composition measures under stronger treatments.…

Template-free synthesis and self-assembly of aligned nickel nanochains under magnetic fields.

Research RF Safe Research Library Jan 1, 2011

This engineering/materials study describes a template-free solution-phase method to synthesize well-aligned nickel nanochains under applied magnetic fields. The authors report that nanochain size and morphology can be tuned by reaction temperature and magnetic field conditions, and explain alignment via magnetic…

Nanocrystalline graphite films nucleation by the radio frequency bias pretreatment.

Research RF Safe Research Library Jan 1, 2011

This paper describes an engineering method for nucleating nanocrystalline carbon films on monocrystalline silicon using a combination of microwave and radio frequency plasma-assisted chemical vapor deposition. The approach is demonstrated via deposition of nanocrystalline diamond after a seeding step and growth of…

Effect of electromagnetic radiofrequency radiation on the rats' brain, liver and kidney cells measured by comet assay.

Research RF Safe Research Library Jan 1, 2011

This animal study assessed DNA damage in rat brain, liver, and kidney cells after repeated whole-body exposure to 915 MHz GSM-modulated RF radiation (SAR 0.6 W/kg) using the comet assay. Tail length was slightly increased in brain cells and differed more notably in liver and kidney samples versus sham controls, while…

Down-regulation of metallothionein 1 and 2 after exposure to electromagnetic field in mouse testis.

Research RF Safe Research Library Jan 1, 2011

This animal study examined mouse testis after 8 weeks of exposure to a 3 MT electromagnetic field (4 hours/day). The authors report significant histological changes (increased primary spermatocytes, increased Leydig cells, and increased basement membrane thickness) in exposed mice versus controls. MT1 and MT2…

Efficiency of radiofrequency assisted uvulopalatopharyngoplasty in the treatment of snoring.

Research RF Safe Research Library Jan 1, 2011

This pre/post clinical study evaluated radiofrequency-assisted uvulopalatopharyngoplasty for snoring using polysomnography before and after surgery in 22 patients. The abstract reports a statistically significant postoperative reduction in snoring, with most patients showing decreased snoring index. The work concerns…

[Realization of mobile phone based wireless blood pressure monitoring system and its preliminary implementation].

Research RF Safe Research Library Jan 1, 2011

This paper describes the design and preliminary implementation of a mobile-phone-based wireless blood pressure monitoring system that transmits data via Bluetooth and computes blood pressure and heart rate on the phone. The authors state that experiments demonstrated the device’s reliability and stability, and that…

Hyperthermic effects of dissipative structures of magnetic nanoparticles in large alternating magnetic fields.

Research RF Safe Research Library Jan 1, 2011

This paper addresses heat dissipation mechanisms of magnetic nanoparticles used in targeted hyperthermia under large alternating magnetic fields. Using numerical comparisons, it reports additional features in relaxation loss for rotatable superparamagnetic nanoparticles and field-induced formation of oriented…

Isolated Atrial Lead Conduction Delay following Right Atrial Radiofrequency Maze Procedure.

Research RF Safe Research Library Jan 1, 2011

This case report describes a 60-year-old man with a dual-chamber implantable cardioverter defibrillator who underwent septal myectomy and a right atrial radiofrequency maze procedure. Following surgery, a persistent delay in atrial sensing was observed. The authors attribute this most likely to iatrogenic right…

Dynamic control of adsorption sensitivity for photo-EMF-based ammonia gas sensors using a wireless network.

Research RF Safe Research Library Jan 1, 2011

This engineering paper proposes a control method for a photo-electromagnetic field (EMF)-based ammonia gas sensor that uses a wireless network and adjusts illumination light intensity. It reports that measurement error is minimized over 3800 ppm ammonia when the concentration corresponds to an optimal illumination…

Fuzzy mobile-robot positioning in intelligent spaces using wireless sensor networks.

Research RF Safe Research Library Jan 1, 2011

This engineering study develops and experimentally evaluates a fuzzy-logic method for locating mobile robots in an intelligent space using wireless sensor networks. Localization relies on inter-node range measurements estimated from RF signal strength attenuation, which the authors describe as noisy and unreliable.…

Interoperation of an UHF RFID reader and a TCP/IP device via wired and wireless links.

Research RF Safe Research Library Jan 1, 2011

This engineering paper describes a system implementation for interoperation between a 915 MHz UHF RFID reader and a TCP/IP gateway device. The architecture uses wired communication between the TCP/IP device and RFID reader, and wireless ZigBee (IEEE 802.15.4) links to an end-device/coordinator. Web-based tests are…

Historical building monitoring using an energy-efficient scalable wireless sensor network architecture.

Research RF Safe Research Library Jan 1, 2011

This engineering paper describes low-power wireless sensor nodes and a cluster-based dynamic-tree hierarchical WSN architecture for monitoring historical buildings and wooden artifacts for early pest detection. The authors report simulation and demonstration results indicating improved scalability and reliability…

Response identification in the extremely low frequency region of an electret condenser microphone.

Research RF Safe Research Library Jan 1, 2011

This engineering study describes an experimental setup using a small electret condenser microphone connected to a notebook/PC to detect extremely low frequency signals. Using a small air cell made from a drilled DVD plate with a speaker and microphone on opposite sides, the microphone captured signals in the 0.5–20…

Effects of extremely low frequency magnetic field on oxidative balance in brain of rats.

Research RF Safe Research Library Jan 1, 2011

This animal study examined whether an extremely low frequency magnetic field (7 mT, 40 Hz) used in magnetotherapy alters oxidative balance in rat brain after 10 days of exposure. The 30 min/day exposure condition was associated with increased lipid peroxidation, while the 60 min/day condition was associated with…

Electric field analysis of breast tumor cells.

Research RF Safe Research Library Jan 1, 2011

This paper reports a MAXWELL 3D simulation study of electric field distribution in a tissue/tumor model relevant to electrical-pulse-mediated drug delivery. The authors report lower electric field strength in tumor tissue compared with normal cells. They interpret this as potentially increasing tumor susceptibility…

[Psychophysiological indicators for children using mobile phones. Communication 1. Current state of the problem].

Research RF Safe Research Library Jan 1, 2011

This article reviews epidemiological and experimental evidence on electromagnetic radiation from mobile phones in humans and animals. It focuses in detail on potential effects on children. The abstract reports that children are more sensitive to this type of exposure than adults.

← Prev Page 28 / 33 Next →