Effect of 60 minutes exposure to electromagnetic field on fecundity, learning and memory, speed of movement and whole body protein of the fruit fly Drosophila melanogaster.

Research RF Safe Research Library Jan 1, 2012

This animal study exposed Drosophila melanogaster to EMF from four electrical devices for 60 minutes and assessed fecundity, larval behavior, and protein patterns. The authors report no significant effect on adult fecundity, but report changes in larval learning/memory and movement speed, with the largest effects in…

Electromagnetic energy radiated from mobile phone alters electrocardiographic records of patients with ischemic heart disease.

Research RF Safe Research Library Jan 1, 2012

This study assessed whether mobile phone radiofrequency exposure during a 40-second ringing period alters ECG parameters in 356 participants across cardiac disease groups, with gender stratification. The authors report QTc prolongation in males across groups, including males with ischemic heart disease, and…

Tunable optical antennas based on metallic nanoshells with nanoknobs.

Research RF Safe Research Library Jan 1, 2012

This engineering study investigates a plasmonic nanostructure composed of a spherical metallic nanoshell with a small metallic nanoparticle (“nanoknob”) on its surface. It reports tunable plasmon resonance behavior driven by nanoshell properties and localized/enhanced electromagnetic fields near the nanoknob under…

Comparison of 2 methods of non-invasive treatment between transcutaneous electrical stimulation and pulsed electromagnetic field stimulation as replacement of invasive manual acupuncture.

Research RF Safe Research Library Jan 1, 2012

This study compared two non-invasive acupoint stimulation methods—TEAS and PEMF—as alternatives to manual acupuncture for recovery from exercise-induced muscle fatigue. Using 2 Hz stimulation (PEMF magnetic flux 30.92 mT), the authors report faster recovery of EMG median frequency and improved peak torque recovery in…

Effect of extremely low frequency electromagnetic field exposure on sleep quality in high voltage substations.

Research RF Safe Research Library Jan 1, 2012

This case-control study measured electric field intensity and magnetic flux density in high voltage substations and estimated workers' ELF-EMF exposure over a shift. Sleep quality was assessed using the PSQI in 67 exposed workers and 110 controls. The study reports no statistically significant difference in overall…

Simulations of magnetic field generation in unmagnetized plasmas via beat-wave current drive.

Research RF Safe Research Library Jan 1, 2012

This paper reports the scientific basis and 2D electromagnetic particle-in-cell simulation results for magnetizing an initially unmagnetized plasma using beat-wave current drive. Simulations across different angles between injected waves show beat-wave generation consistent with theoretical predictions and reveal…

Non-Markovian stationary probability density for a harmonic oscillator in an electromagnetic field.

Research RF Safe Research Library Jan 1, 2012

This paper presents a theoretical calculation of the stationary probability density for a harmonic oscillator embedded in an electromagnetic field by solving the Fokker-Planck equation exactly. The magnetic field is treated as constant, while the electric field is modeled as an external stochastic force with…

Low-frequency electromagnetic fields do not alter responses of inflammatory genes and proteins in human monocytes and immune cell lines.

Research RF Safe Research Library Jan 1, 2012

This in vitro study examined whether low-frequency electromagnetic fields (a complex multiple waveform field and a 50 Hz sine wave) alter inflammatory gene and protein responses in human immune cells. Across time course experiments in THP-1 cells and primary monocytes/macrophages, the authors report no significant…

Peripheral pulsed electromagnetic fields may reduce the placebo effect in migraine patients that do not respond to the sham intervention in a randomized, placebo-controlled, double-blind, cross-over clinical trial.

Research RF Safe Research Library Jan 1, 2012

This randomized, placebo-controlled, double-blind, cross-over trial evaluated a wrist-applied PEMF bracelet in 18 migraine patients and examined possible modulation of placebo effects. In the overall group, both PEMF and placebo were associated with similar reductions in migraine frequency and intensity. The authors…

Application of an induced field sensor for assessment of electromagnetic exposure from compact fluorescent lamps.

Research RF Safe Research Library Jan 1, 2012

This study investigates instrumentation and procedures to assess electromagnetic exposure from compact fluorescent lamps (CFLs) by measuring both incident and induced fields in the 10 kHz–1 MHz range. For some CFLs, incident electric fields exceeded ICNIRP reference levels at close distances, but induced fields were…

Correction of microcirculatory disturbances with terahertz electromagnetic radiation at nitric oxide frequencies in albino rats under conditions of acute stress.

Research RF Safe Research Library Jan 1, 2011

This animal study reports that terahertz electromagnetic irradiation at nitric oxide (NO)-related frequencies (150.176150.664 GHz) corrected peripheral microcirculatory disturbances in albino rats experiencing acute immobilization stress. The abstract frames the effect as a correction of stress-related peripheral…

Hematological and toxicogenomic effects of ferromagnetic screening of natural electromagnetic fields.

Research RF Safe Research Library Jan 1, 2011

This rat study tracked hematological and toxicogenomic aftereffects over 45 days following 2 days of ferromagnetic screening of natural electromagnetic fields. The authors report leukopenia at day 14 and increases in genomic instability markers (aneuploidy and polyploidy) in male leukocytes persisting after screening…

Effect of electromagnetic radiofrequency radiation on the rats' brain, liver and kidney cells measured by comet assay.

Research RF Safe Research Library Jan 1, 2011

This animal study assessed DNA damage in rat brain, liver, and kidney cells after repeated whole-body exposure to 915 MHz GSM-modulated RF radiation (SAR 0.6 W/kg) using the comet assay. Tail length was slightly increased in brain cells and differed more notably in liver and kidney samples versus sham controls, while…

Down-regulation of metallothionein 1 and 2 after exposure to electromagnetic field in mouse testis.

Research RF Safe Research Library Jan 1, 2011

This animal study examined mouse testis after 8 weeks of exposure to a 3 MT electromagnetic field (4 hours/day). The authors report significant histological changes (increased primary spermatocytes, increased Leydig cells, and increased basement membrane thickness) in exposed mice versus controls. MT1 and MT2…

Dynamic control of adsorption sensitivity for photo-EMF-based ammonia gas sensors using a wireless network.

Research RF Safe Research Library Jan 1, 2011

This engineering paper proposes a control method for a photo-electromagnetic field (EMF)-based ammonia gas sensor that uses a wireless network and adjusts illumination light intensity. It reports that measurement error is minimized over 3800 ppm ammonia when the concentration corresponds to an optimal illumination…

[Time effect of sinusoidal electromagnetic field on enhancing the maturation and mineralization of osteoblasts in vitro].

Research RF Safe Research Library Jan 1, 2011

This in vitro study exposed newborn rat calvarial osteoblasts to 50 Hz sinusoidal electromagnetic fields at 1.8 mT for different daily exposure times (0.5–3.0 h). The authors report inhibited osteoblast proliferation at longer exposure times, alongside increased differentiation markers (ALP activity) and…

[Psychophysiological indicators for children using mobile phones. Communication 1. Current state of the problem].

Research RF Safe Research Library Jan 1, 2011

This article reviews epidemiological and experimental evidence on electromagnetic radiation from mobile phones in humans and animals. It focuses in detail on potential effects on children. The abstract reports that children are more sensitive to this type of exposure than adults.

Human keratinocytes in culture exhibit no response when exposed to short duration, low amplitude, high frequency (900 MHz) electromagnetic fields in a reverberation chamber.

Research RF Safe Research Library Jan 1, 2011

This in vitro study exposed normal human epidermal keratinocytes to non-thermal 900 MHz electromagnetic fields in a mode-stirred reverberation chamber under two short-duration conditions. Microarray analysis found only limited gene modulation (20 genes) with small expression ratios and no shared genes across…

Effects of low frequency electromagnetic fields on the chondrogenic differentiation of human mesenchymal stem cells.

Research RF Safe Research Library Jan 1, 2011

This in vitro study examined whether extremely low-frequency magnetic fields affect chondrogenic differentiation of human mesenchymal stem cells in pellet culture. Cells exposed for 3 weeks to a homogeneous sinusoidal 5 mT magnetic field showed increased collagen type II expression (significant at passage 6) and…

[Dependence of the non-thermal radiofrequency electromagnetic field bioeffects on the typological features of electroencephalogram in humans].

Research RF Safe Research Library Jan 1, 2010

This volunteer study examined short-term non-thermal RF EMF exposure and reported changes in EEG spectra. The main reported effect was amplification of alpha-range energy, with the magnitude depending on baseline EEG typological features. The abstract also reports that combining RF EMF exposure with monotonous…

In vitro tests reveal sample radiofrequency identification readers inducing clinically significant electromagnetic interference to implantable pacemakers and implantable cardioverter-defibrillators.

Research RF Safe Research Library Jan 1, 2010

This in vitro study tested electromagnetic compatibility between passive RFID readers and 15 pacemakers plus 15 ICDs across 134 kHz, 13.56 MHz, and 915 MHz bands. EMI reactions were common with low-frequency RFID and rare with high-frequency RFID, while no reactions were observed with ultra-high-frequency or…

Electromagnetic fields and DNA damage

Research RF Safe Research Library Jan 1, 2009

This review discusses the comet assay and summarizes research on non-ionizing EMF exposure and DNA/chromosomal damage. It describes both positive and negative findings across studies, noting no consistent overall pattern for radiofrequency radiation (RFR). The authors nonetheless conclude that under certain exposure…

Evaluation of the efficacy of pulsed electromagnetic field in the management of patients with diabetic polyneuropathy.

Research RF Safe Research Library Jan 1, 2009

This randomized controlled trial evaluated low-power, low-frequency pulsed electromagnetic field (PEMF) therapy at 600 Hz and 800 Hz as an adjunct treatment for diabetic polyneuropathy. Thirty participants were randomized to 600 Hz PEMF, 800 Hz PEMF, or usual medical treatment for 12 days. The abstract reports…

[Female genital toxicities of high-frequency electromagnetic field on rats].

Research RF Safe Research Library Jan 1, 2009

This rat study examined sub-chronic exposure to a 30 MHz electromagnetic field at 0–1600 V/m for 8 hours/day, 5 days/week, over 56 days. The authors report no change in ovarian wet weight, but dose-related changes in estrous cycle timing, reproductive hormones (higher LH and lower E2 at higher exposures), and ovarian…

Biological effects from electromagnetic field exposure and public exposure standards

Research RF Safe Research Library Jan 1, 2008

This review describes public concerns and scientific reports of non-thermal biological effects from low-intensity ELF and RF exposures. It lists multiple health endpoints reported to be associated with ELF and/or RF and highlights the BioInitiative Report’s conclusion that a reasonable suspicion of risk exists at…