Archive

762 posts

Showing results for: TiN

Evaluation of the packaging and encapsulation reliability in fully integrated, fully wireless 100 channel Utah Slant Electrode Array (USEA): Implications for long term functionality.

Research RF Safe Research Library Jan 1, 2012

This engineering study evaluated long-term encapsulation and packaging reliability of a fully wireless 100-channel Utah Slant Electrode Array system in vitro. The device was soaked in PBS for over 12 months while being wirelessly powered/configured at 2.765 MHz and transmitting an FSK-modulated 900 MHz RF signal. The…

Electric Field Controlled Self-Assembly of Hierarchically Ordered Membranes.

Research RF Safe Research Library Jan 1, 2012

This in vitro study examined how an externally applied electric field influences the self-assembly of oppositely charged molecules in water into an ordered membrane. The authors report that electric fields changed the kinetics of membrane formation and altered membrane thickness, nanofiber growth orientation, and…

The mobile phone as a tool in improving cancer care in Nigeria.

Research RF Safe Research Library Jan 1, 2012

This study evaluated mobile phone use as a tool to improve cancer care follow-up and communication in a low-resource Nigerian setting. Among 1176 oncology patients, sustained follow-up at 24 months was reported as much higher in those receiving the phone intervention than in those who did not. Patients also reported…

A robotic assistant for trans-oral surgery: the robotic endo-laryngeal flexible (Robo-ELF) scope.

Research RF Safe Research Library Jan 1, 2012

This paper describes an engineering/clinical tool development effort: the Robotic EndoLaryngeal Flexible (Robo-ELF) Scope System for manipulating flexible endoscopes in laryngeal surgery. The system includes multiple degrees of freedom, a passive positioning arm, and a custom joystick controller enabling one-handed…

Allergic contact dermatitis caused by a cell phone cover.

Research RF Safe Research Library Jan 1, 2012

This case report describes allergic contact dermatitis attributed to a cell phone cover that was advertised as silicone only. Patch testing with the cover material confirmed the diagnosis, and additional patch testing showed reactions to multiple plastics/glues allergens. The authors suggest that as phone cover use…

Long-term digital mobile phone use and cognitive decline in the elderly.

Research RF Safe Research Library Jan 1, 2012

This 4-year cohort study in 871 non-demented older Chinese adults examined frequent digital mobile phone use and changes in cognitive performance. The authors report no significant harmful association between phone use and cognitive functioning. They note users tended to have characteristics linked to better…

Influence of magnetic field on aqueous two-phase extraction of horse ferritin in the polyethylene glycol/hydroxyethyl starch system.

Research RF Safe Research Library Jan 1, 2012

This study reports an aqueous two-phase extraction method for equine spleen ferritin using polyethylene glycol (PEG) and hydroxyethyl starch (HES). Ferritin partitioning depended on PEG/HES concentrations and PEG molecular weight, and applying a magnetic field increased ferritin accumulation in the PEG-rich phase…

Effects of radiofrequency radiation exposure on blood-brain barrier permeability in male and female rats

Research RF Safe Research Library Jan 1, 2011

This rat study tested whether acute exposure to 0.9 and 1.8 GHz continuous-wave radiofrequency radiation alters blood-brain barrier permeability. Using Evans-blue/albumin as a tracer, the authors report no BBB leakage in exposed female rats but a significant increase in albumin in exposed male rat brains versus sham.…

Influences of electric field on living cells in a charged water-in-oil droplet under electrophoretic actuation.

Research RF Safe Research Library Jan 1, 2011

This experimental study examined whether strong electric fields used for electrophoretic actuation of charged water-in-oil droplets affect living cells inside the droplets. Using Trypan blue and cell growth tests across electric field strengths of 1–3 kV/cm and varying actuation times, the authors report no…

Short-term effects of pulsed radiofrequency on chronic refractory cervical radicular pain.

Research RF Safe Research Library Jan 1, 2011

This small clinical study evaluated pulsed radiofrequency applied to the cervical dorsal root ganglion in patients with chronic refractory cervical radicular pain. Pain (VAS) and disability (NDI) improved over 3 months, with most patients reporting ≥50% pain relief and satisfaction at follow-up. No adverse effects…

Experimental study of relationship between biological hazards of low-dose radiofrequency exposure and energy flow density in Spirostomum ambiguum infusoria exposed at a mobile connection frequency (1 GHz).

Research RF Safe Research Library Jan 1, 2011

This experimental study exposed Spirostomum ambiguum infusoria to 1 GHz radiofrequency fields at 5 and 50 μW/cm² and reports reduced motor activity. The effect was described as threshold-like, appearing after a certain exposure duration and not increasing with longer exposure. The authors report different 'safe'…

Hematological and toxicogenomic effects of ferromagnetic screening of natural electromagnetic fields.

Research RF Safe Research Library Jan 1, 2011

This rat study tracked hematological and toxicogenomic aftereffects over 45 days following 2 days of ferromagnetic screening of natural electromagnetic fields. The authors report leukopenia at day 14 and increases in genomic instability markers (aneuploidy and polyploidy) in male leukocytes persisting after screening…

Nanocrystalline graphite films nucleation by the radio frequency bias pretreatment.

Research RF Safe Research Library Jan 1, 2011

This paper describes an engineering method for nucleating nanocrystalline carbon films on monocrystalline silicon using a combination of microwave and radio frequency plasma-assisted chemical vapor deposition. The approach is demonstrated via deposition of nanocrystalline diamond after a seeding step and growth of…

Hyperthermic effects of dissipative structures of magnetic nanoparticles in large alternating magnetic fields.

Research RF Safe Research Library Jan 1, 2011

This paper addresses heat dissipation mechanisms of magnetic nanoparticles used in targeted hyperthermia under large alternating magnetic fields. Using numerical comparisons, it reports additional features in relaxation loss for rotatable superparamagnetic nanoparticles and field-induced formation of oriented…

Isolated Atrial Lead Conduction Delay following Right Atrial Radiofrequency Maze Procedure.

Research RF Safe Research Library Jan 1, 2011

This case report describes a 60-year-old man with a dual-chamber implantable cardioverter defibrillator who underwent septal myectomy and a right atrial radiofrequency maze procedure. Following surgery, a persistent delay in atrial sensing was observed. The authors attribute this most likely to iatrogenic right…

Fuzzy mobile-robot positioning in intelligent spaces using wireless sensor networks.

Research RF Safe Research Library Jan 1, 2011

This engineering study develops and experimentally evaluates a fuzzy-logic method for locating mobile robots in an intelligent space using wireless sensor networks. Localization relies on inter-node range measurements estimated from RF signal strength attenuation, which the authors describe as noisy and unreliable.…

Historical building monitoring using an energy-efficient scalable wireless sensor network architecture.

Research RF Safe Research Library Jan 1, 2011

This engineering paper describes low-power wireless sensor nodes and a cluster-based dynamic-tree hierarchical WSN architecture for monitoring historical buildings and wooden artifacts for early pest detection. The authors report simulation and demonstration results indicating improved scalability and reliability…

Response identification in the extremely low frequency region of an electret condenser microphone.

Research RF Safe Research Library Jan 1, 2011

This engineering study describes an experimental setup using a small electret condenser microphone connected to a notebook/PC to detect extremely low frequency signals. Using a small air cell made from a drilled DVD plate with a speaker and microphone on opposite sides, the microphone captured signals in the 0.5–20…

Mobile phones and short message service texts to collect situational awareness data during simulated public health critical events.

Research RF Safe Research Library Jan 1, 2011

This university-based pilot study evaluated whether two-way SMS text messaging could be used to collect situational assessment data during simulated public health critical events. Among 63 enrolled students, 76.7% of prompted SMS surveys were completed, and most responses were returned quickly. The authors conclude…

[Time effect of sinusoidal electromagnetic field on enhancing the maturation and mineralization of osteoblasts in vitro].

Research RF Safe Research Library Jan 1, 2011

This in vitro study exposed newborn rat calvarial osteoblasts to 50 Hz sinusoidal electromagnetic fields at 1.8 mT for different daily exposure times (0.5–3.0 h). The authors report inhibited osteoblast proliferation at longer exposure times, alongside increased differentiation markers (ALP activity) and…

Electric field analysis of breast tumor cells.

Research RF Safe Research Library Jan 1, 2011

This paper reports a MAXWELL 3D simulation study of electric field distribution in a tissue/tumor model relevant to electrical-pulse-mediated drug delivery. The authors report lower electric field strength in tumor tissue compared with normal cells. They interpret this as potentially increasing tumor susceptibility…

Measurement of creatine kinase reaction rate in human brain using magnetization transfer image-selected in vivo spectroscopy (MT-ISIS) and a volume ³¹P/¹H radiofrequency coil in a clinical 3-T MRI system.

Research RF Safe Research Library Jan 1, 2011

This paper describes a new magnetization transfer 31P MRS approach (MT-ISIS) for measuring the creatine kinase forward reaction rate in the human brain using a volume 31P/1H RF coil on a clinical 3-T MRI system. The method aims to reduce acquisition time (30 min), avoid scalp muscle contamination, improve RF…

Reduction of implant RF heating through modification of transmit coil electric field.

Research RF Safe Research Library Jan 1, 2011

This engineering study describes modifying MRI RF transmit coil electric-field distributions to create electric field-free zones without substantially changing transmit sensitivity. Phantom experiments are reported to show reduced implant heating when a zero electric-field plane is aligned with the implant location.…

Transient and steady-state magnetic fields induce increased fluorodeoxyglucose uptake in the rat hindbrain.

Research RF Safe Research Library Jan 1, 2011

This animal PET study examined whether a weak 60-Hz magnetic field alters brain glucose utilization in rats. The abstract reports increased FDG uptake in hindbrain voxels when a 2.5-G field was oriented orthogonally to the sagittal plane, but not when field direction varied randomly. Distinct activation effects were…

Human keratinocytes in culture exhibit no response when exposed to short duration, low amplitude, high frequency (900 MHz) electromagnetic fields in a reverberation chamber.

Research RF Safe Research Library Jan 1, 2011

This in vitro study exposed normal human epidermal keratinocytes to non-thermal 900 MHz electromagnetic fields in a mode-stirred reverberation chamber under two short-duration conditions. Microarray analysis found only limited gene modulation (20 genes) with small expression ratios and no shared genes across…

← Prev Page 27 / 31 Next →