Archive

742 posts

Showing results for: SES

Effects of chain stiffness and salt concentration on responses of polyelectrolyte brushes under external electric field.

Research RF Safe Research Library Jan 1, 2011

This paper reports molecular dynamics simulations of polyelectrolyte brushes subjected to external electric fields, focusing on how chain stiffness and salt concentration affect responses. The simulations suggest higher salt concentrations strengthen an induced opposing field from ion redistribution, which resists…

A handheld preconcentrator for the rapid collection of cancerous cells using dielectrophoresis generated by circular microelectrodes in stepping electric fields.

Research RF Safe Research Library Jan 1, 2011

This engineering study describes a handheld microfluidic preconcentrator that uses dielectrophoresis generated by circular microelectrodes with a stepping electric field. Numerical simulations were used to illustrate the electric-field concept. In experiments, HeLa cells were reportedly preconcentrated within 160…

Hematological and toxicogenomic effects of ferromagnetic screening of natural electromagnetic fields.

Research RF Safe Research Library Jan 1, 2011

This rat study tracked hematological and toxicogenomic aftereffects over 45 days following 2 days of ferromagnetic screening of natural electromagnetic fields. The authors report leukopenia at day 14 and increases in genomic instability markers (aneuploidy and polyploidy) in male leukocytes persisting after screening…

Milk processed by pulsed electric fields: evaluation of microbial quality, physicochemical characteristics, and selected nutrients at different storage conditions.

Research RF Safe Research Library Jan 1, 2011

This study evaluated pulsed electric fields (PEF) as a pasteurization method for raw skim and whole milk across multiple treatment intensities and storage conditions. The abstract reports only minor changes in physicochemical properties and small decreases in some composition measures under stronger treatments.…

Effect of electromagnetic radiofrequency radiation on the rats' brain, liver and kidney cells measured by comet assay.

Research RF Safe Research Library Jan 1, 2011

This animal study assessed DNA damage in rat brain, liver, and kidney cells after repeated whole-body exposure to 915 MHz GSM-modulated RF radiation (SAR 0.6 W/kg) using the comet assay. Tail length was slightly increased in brain cells and differed more notably in liver and kidney samples versus sham controls, while…

[Realization of mobile phone based wireless blood pressure monitoring system and its preliminary implementation].

Research RF Safe Research Library Jan 1, 2011

This paper describes the design and preliminary implementation of a mobile-phone-based wireless blood pressure monitoring system that transmits data via Bluetooth and computes blood pressure and heart rate on the phone. The authors state that experiments demonstrated the device’s reliability and stability, and that…

Hyperthermic effects of dissipative structures of magnetic nanoparticles in large alternating magnetic fields.

Research RF Safe Research Library Jan 1, 2011

This paper addresses heat dissipation mechanisms of magnetic nanoparticles used in targeted hyperthermia under large alternating magnetic fields. Using numerical comparisons, it reports additional features in relaxation loss for rotatable superparamagnetic nanoparticles and field-induced formation of oriented…

Dynamic control of adsorption sensitivity for photo-EMF-based ammonia gas sensors using a wireless network.

Research RF Safe Research Library Jan 1, 2011

This engineering paper proposes a control method for a photo-electromagnetic field (EMF)-based ammonia gas sensor that uses a wireless network and adjusts illumination light intensity. It reports that measurement error is minimized over 3800 ppm ammonia when the concentration corresponds to an optimal illumination…

Interoperation of an UHF RFID reader and a TCP/IP device via wired and wireless links.

Research RF Safe Research Library Jan 1, 2011

This engineering paper describes a system implementation for interoperation between a 915 MHz UHF RFID reader and a TCP/IP gateway device. The architecture uses wired communication between the TCP/IP device and RFID reader, and wireless ZigBee (IEEE 802.15.4) links to an end-device/coordinator. Web-based tests are…

Mobile phones and short message service texts to collect situational awareness data during simulated public health critical events.

Research RF Safe Research Library Jan 1, 2011

This university-based pilot study evaluated whether two-way SMS text messaging could be used to collect situational assessment data during simulated public health critical events. Among 63 enrolled students, 76.7% of prompted SMS surveys were completed, and most responses were returned quickly. The authors conclude…

[Clinical efficacy of acne scar treatment with micro-plasma radio frequency].

Research RF Safe Research Library Jan 1, 2011

This clinical study evaluated micro-plasma radio frequency treatment for facial acne scars in 24 patients. Patients received 3–5 treatments and were assessed using photographs before and 2 months after treatment. The authors report an overall improvement rate of 83.33% and conclude the technique is effective.

Effects of extremely low frequency magnetic field on oxidative balance in brain of rats.

Research RF Safe Research Library Jan 1, 2011

This animal study examined whether an extremely low frequency magnetic field (7 mT, 40 Hz) used in magnetotherapy alters oxidative balance in rat brain after 10 days of exposure. The 30 min/day exposure condition was associated with increased lipid peroxidation, while the 60 min/day condition was associated with…

[Psychophysiological indicators for children using mobile phones. Communication 1. Current state of the problem].

Research RF Safe Research Library Jan 1, 2011

This article reviews epidemiological and experimental evidence on electromagnetic radiation from mobile phones in humans and animals. It focuses in detail on potential effects on children. The abstract reports that children are more sensitive to this type of exposure than adults.

A radiofrequency coil to facilitate B₁⁺ shimming and parallel imaging acceleration in three dimensions at 7 T.

Research RF Safe Research Library Jan 1, 2011

This paper reports the development of a 15-channel transmit-receive RF coil for 7 T human brain MRI, using a hybrid decoupling approach to support element placement along three axes. The design is presented as enabling B1+ shimming and parallel imaging acceleration in three dimensions, with reported isolation and…

Measurement of creatine kinase reaction rate in human brain using magnetization transfer image-selected in vivo spectroscopy (MT-ISIS) and a volume ³¹P/¹H radiofrequency coil in a clinical 3-T MRI system.

Research RF Safe Research Library Jan 1, 2011

This paper describes a new magnetization transfer 31P MRS approach (MT-ISIS) for measuring the creatine kinase forward reaction rate in the human brain using a volume 31P/1H RF coil on a clinical 3-T MRI system. The method aims to reduce acquisition time (30 min), avoid scalp muscle contamination, improve RF…

Impact of a pulsed electric field on damage of plant tissues: effects of cell size and tissue electrical conductivity.

Research RF Safe Research Library Jan 1, 2011

This experimental and modeling study examined pulsed electric field (PEF) permeabilization in several fruit and vegetable tissues at 293 K using 1000 μs pulses and field strengths of 400 and 1000 V·cm(-1). While electroporation theory predicts greater damage in tissues with larger cells, the authors report this…

Correction of main and transmit magnetic field (B0 and B1) inhomogeneity effects in multicomponent-driven equilibrium single-pulse observation of T1 and T2.

Research RF Safe Research Library Jan 1, 2011

This methods paper addresses how B0 (main field) and B1 (transmit field) inhomogeneities can bias SPGR and bSSFP steady-state MRI signals used for multicomponent T1/T2 relaxometry and myelin water analysis. It describes using DESPOT1-HIFI to calibrate flip angles and adding a B0-related parameter with multiple…

Evaluation of magnetic resonance safety of veterinary radiofrequency identification devices at 1 T.

Research RF Safe Research Library Jan 1, 2011

This study evaluated MRI safety parameters for three commercial veterinary RFID microchips at 1 T, assessing movement forces, heating, artifacts, and device function. Translation and torque were reported to be larger than expected from normal activity, but no significant heating was observed and microchip function…

Orientation and Dynamics of ZnO Nanorod Liquid Crystals in Electric Fields.

Research RF Safe Research Library Jan 1, 2010

This materials study reports that ZnO nanorod polymer hybrids can form liquid-crystalline phases and exhibit orientation switching under an applied AC electric field. The orientation reportedly changes from planar to homeotropic, analogous to switching in low-molecular liquid crystals. Dielectric measurements and…

Ohmic heating of peaches in the wide range of frequencies (50 Hz to 1 MHz).

Research RF Safe Research Library Jan 1, 2010

This engineering/food science study examined ohmic heating of peaches at 60 V/cm using bipolar pulses across frequencies from 50 Hz to 1 MHz. Heating time to a target temperature and multiple electrical properties were frequency-dependent, particularly for intact tissue. The authors report faster electro-thermal…

Critical electric field strengths of onion tissues treated by pulsed electric fields.

Research RF Safe Research Library Jan 1, 2010

This experimental study examined how pulsed electric fields affect onion tissue integrity and texture across different field strengths and pulse counts. It reports distinct critical field strengths for plasma membrane versus tonoplast membrane breakdown, with higher thresholds needed for tonoplast disruption. Effects…

Electrooptical effects in colloid systems subjected to short pulses of strong electric field.

Research RF Safe Research Library Jan 1, 2010

This study describes an electrooptical technique for polydisperse colloid solutions using short pulses of strong sine-shaped electric field, intended for systems that cannot withstand prolonged field exposure. The authors report that key particle parameters can still be extracted from the resulting experimental data.…

Spin current pumped by a rotating magnetic field in zigzag graphene nanoribbons.

Research RF Safe Research Library Jan 1, 2010

This theoretical study models electron spin resonance and spin/charge pumping in zigzag graphene nanoribbons driven by a transverse rotating magnetic field without applied bias. It reports that pumped spin current density increases with ribbon size and rotating-field intensity, and that even-chain ribbons can also…

Effects of magnetic field and pressure on the intermediate valence state of YbPd.

Research RF Safe Research Library Jan 1, 2010

This condensed-matter physics study examined how high magnetic fields and pressure affect magnetization, transport, and thermodynamic properties of the intermediate-valence compound YbPd. The authors report that the Yb valence state and two first-order transitions are stable up to 55 T, while increasing pressure…

Electronic properties of a graphene antidot in magnetic fields.

Research RF Safe Research Library Jan 1, 2010

This paper describes unusual electronic properties of a graphene antidot created by a piecewise constant potential in a magnetic field. It reports near-complete localization of electron probability within the barrier region under some conditions and a symmetry linking antidot and dot states with identical…

← Prev Page 27 / 30 Next →