Investigation of Electric Field-Induced Structural Changes at Fe-Doped SrTiO₃ Anode Interfaces by Second Harmonic Generation.
Research
RF Safe Research Library
Jan 1, 2016
This materials study used optical second harmonic generation to detect electric field-induced structural changes at Pt/Fe-doped SrTiO3 anode interfaces. Reduced crystals showed steadily increasing susceptibility with increasing negative voltage, interpreted as electrostriction-related bond distortions. Oxidized…
Influence of Growth Rate and Magnetic Field on Microstructure and Properties of Directionally Solidified Ag-Cu Eutectic Alloy.
Research
RF Safe Research Library
Jan 1, 2016
This materials study examined how growth rate and an external magnetic field affect microstructure and properties in directionally solidified Ag-Cu eutectic alloys. The lamellar spacing followed the Jackson-Hunt model with a reported constant of 5.8 µm³/s. Increasing magnetic field tilted eutectic growth and…
Auto-Tuning and Self-Calibration of High-Sensitivity Radio Frequency Interferometers.
Research
RF Safe Research Library
Jan 1, 2016
This engineering paper demonstrates an auto-tuning method for a high-sensitivity RF interferometer using a tunable liquid attenuator controlled by liquid volume. The authors report an effective quality factor up to 1×10 at ~5 GHz and a self-calibration/measurement process from 2 to 7.5 GHz using a methanol-water…
Comparative assessment of monopolar and bipolar radiofrequency surgery of inferior turbinate.
Research
RF Safe Research Library
Jan 1, 2016
This prospective, randomized, single-blind study compared monopolar versus bipolar radiofrequency surgery for inferior turbinate hypertrophy in 71 patients. Over 6 months, long-term symptom outcomes did not significantly differ between groups. Monopolar radiofrequency showed earlier symptom improvement and less…
Research on in vitro release of Isoniazid (INH) super paramagnetic microspheres in different magnetic fields.
Research
RF Safe Research Library
Jan 1, 2016
This in vitro study examined how different external magnetic field conditions affect isoniazid release from superparamagnetic iron oxide microspheres. The abstract reports that magnetic fields accelerated drug release, with faster release in acidic (pH 3) conditions and the fastest completion (2 hours) under an…
Enzymatic debridement after mobile phone explosion: a case report.
Research
RF Safe Research Library
Jan 1, 2016
This case report describes a paediatric burn injury resulting from a mobile phone lithium-ion battery explosion. The patient was treated with selective enzymatic debridement, which the authors note is simple, minimally invasive, and safe. The report concerns an acute thermal injury mechanism rather than EMF exposure.
An innovative therapy for peri-implantitis based on radio frequency electric current: numerical simulation results and clinical evidence.
Research
RF Safe Research Library
Jan 1, 2016
This conference paper describes a peri-implantitis therapy using radio frequency electric current and presents numerical simulations alongside referenced clinical evidence. The abstract reports 81% successful treatment across 66 implants in 46 patients. FEM modeling suggests current preferentially concentrates in…
A wearable bluetooth LE sensor for patient monitoring during MRI scans.
Research
RF Safe Research Library
Jan 1, 2016
This engineering paper reports a prototype wearable patient-monitoring device that transmits vital-sign measurements via Bluetooth LE during MRI. Across 7 MRI acquisitions (25 minutes total), the authors report no Bluetooth packet loss, increased PPG noise during MRI, and no effect on temperature/humidity readings.…
Variation of radio frequency induced power deposition due to second surrounding tissue.
Research
RF Safe Research Library
Jan 1, 2016
This engineering study investigated RF-induced power deposition from insulated leads of different lengths positioned near two surrounding tissues. The authors report that both the electromagnetic lead models and the resulting power deposition depended strongly on the electrical properties of both tissues. Using a…
Effects of extremely low frequency electromagnetic fields on in-vitro cellular cultures HeLa and CHO.
Research
RF Safe Research Library
Jan 1, 2016
This in-vitro study examined whether 50 Hz extremely low frequency electromagnetic fields affect proliferation in HeLa and CHO cell cultures. The abstract reports increased proliferation in exposed cells versus controls, with the largest reported increase under repetitive exposure at 2.49 mT (40 minutes every 12…
The effect of inter-electrode distance on the electric field distribution during transcutaneous lumbar spinal cord direct current stimulation.
Research
RF Safe Research Library
Jan 1, 2016
This engineering-focused study examined how inter-electrode distance in transcutaneous spinal direct current stimulation (tsDCS) affects electric field distribution in the lumbar and sacral spinal cord. Peak E-field magnitudes occurred in the lumbo-sacral region for all configurations. Larger electrode separations…
Microwave to near-infrared conversion with a millimeter-scale wireless laser for activating molecular transducers.
Research
RF Safe Research Library
Jan 1, 2016
This conference paper reports an engineering approach to convert wireless microwave power into near-infrared light using a miniaturized, wirelessly powered laser. The device is described as millimeter-scale and capable of being powered through >1 cm of tissue. The abstract focuses on enabling in vivo activation of…
Improving resolution of robotic capsule locomotion using dynamic electromagnetic field.
Research
RF Safe Research Library
Jan 1, 2016
This engineering conference paper describes a method for controlling the locomotion of swallowable wireless capsule endoscopy devices using a dynamic magnetic field generated by external coils. A permanent magnet embedded in the capsule is manipulated by adjusting external field strengths to maintain equilibrium for…
[Genic and non-genic regulation of low frequence pulsed electromagnetic fields on osteoblasts differentiation].
Research
RF Safe Research Library
Jan 1, 2016
This in vitro study exposed rat calvarial osteoblasts to 50 Hz, 0.6 mT pulsed electromagnetic fields for 1.5 hours and measured early differentiation-related markers over 0–12 hours. The abstract reports increased ALP activity at 3 hours and time-dependent changes in ALP, Runx2, and OSX transcription and Runx2/OSX…
[Effects of 1.8 mT sinusoidal alternating electromagnetic fields of different frequencies on bone biomechanics of young rats].
Research
RF Safe Research Library
Jan 1, 2016
This randomized animal experiment exposed 32 young female rats to 1.8 mT sinusoidal alternating electromagnetic fields at 10, 25, or 40 Hz for 90 minutes per day. The 10 Hz and 40 Hz groups had higher BMD and improved femur and lumbar vertebra biomechanical properties compared with controls, and micro-CT suggested…
Disordered redox metabolism of brain cells in rats exposed to low doses of ionizing radiation or UHF electromagnetic radiation.
Research
RF Safe Research Library
Jan 1, 2016
This animal study assessed redox-state changes in rat brain cells after long-term low-intensity ionizing radiation exposure or fractionated non-thermal UHF electromagnetic radiation. Both exposures were associated with decreased ubisemiquinone and increased NO-FeS-protein complexes, alongside increased mitochondrial…
Radiofrequency microtenotomy is as effective as plantar fasciotomy in the treatment of recalcitrant plantar fasciitis.
Research
RF Safe Research Library
Jan 1, 2016
This single-institution cohort analysis compared radiofrequency microtenotomy with plantar fasciotomy for recalcitrant plantar fasciitis, including a group receiving both procedures. Patient-reported outcomes (SF-36, AOFAS) and satisfaction/expectations were reportedly similar across procedures at 6 months and 1…
Magnetophoretic Conductors and Diodes in a 3D Magnetic Field.
Research
RF Safe Research Library
Jan 1, 2016
This engineering study demonstrates magnetophoretic track designs that transport single magnetized beads and magnetically labeled single cells in a 3D time-varying magnetic field. A vertical field bias is reported to reduce particle clustering but necessitates redesigned track geometries with alternating curvature.…
Sweeping of hydrophobic amines under inhomogeneous electric field and low surfactant concentration in micellar electrokinetic chromatography.
Research
RF Safe Research Library
Jan 1, 2016
This laboratory/analytical study examined how sample matrix affects sample sweeping in micellar electrokinetic chromatography under an inhomogeneous electric field. It reports strong focusing for hydrophobic cationic analytes when the sample matrix conductivity is much higher than the BGE, even with low surfactant…
Effects of Anatomical Differences on Electromagnetic Fields, SAR, and Temperature Change.
Research
RF Safe Research Library
Jan 1, 2016
This engineering study evaluates how anatomical/geometric differences affect MRI RF safety metrics. Simulations and a bovine-phantom experiment found that similar transmit B-field patterns can coincide with notably different peak SAR and temperature rise. The authors highlight challenges in using…
Effects of Electromagnetic Radiation from Smartphones on Learning Ability and Hippocampal Progenitor Cell Proliferation in Mice.
Research
RF Safe Research Library
Jan 1, 2016
This mouse study examined chronic smartphone electromagnetic radiation exposure and its effects on spatial working memory and hippocampal progenitor cell proliferation. The authors report no significant differences in Y-maze spontaneous alternation or BrdU-labeled progenitor proliferation after exposure, but…
Effect of zero magnetic field on cardiovascular system and microcirculation.
Research
RF Safe Research Library
Jan 1, 2016
This study examined cardiovascular and microcirculation responses in healthy adults under zero magnetic field conditions generated by an "ARFA" magnetic field modeling facility. Participants were tested twice, once in zero magnetic field and once in a sham condition, with measures including capillary blood flow,…
Effects of electromagnetic field (1.8/0.9 GHz) exposure on growth plate in growing rats.
Research
RF Safe Research Library
Jan 1, 2016
This animal study examined whole-body RF-EMF exposure (900 or 1800 MHz) for 2 hours/day over 90 days in growing male rats, compared with sham controls. Exposed rats showed greater weight and length increases and higher levels of several hormones and calcium. The study also reports changes in femoral growth plate…
Wireless Fidelity Electromagnetic Field Exposure Monitoring With Wearable Body Sensor Networks.
Research
RF Safe Research Library
Jan 1, 2016
This engineering paper presents an experimentally validated wearable personal exposimeter system for RF-EMF exposure monitoring, motivated by increasing wireless applications. It uses a distributed measurement approach and integrates inertial sensors to capture activity and posture during measurements. The system is…
Cardiac magnetic resonance radiofrequency tissue tagging for diagnosis of constrictive pericarditis: A proof of concept study.
Research
RF Safe Research Library
Jan 1, 2016
This proof-of-concept cohort study evaluated cardiac magnetic resonance (CMR) radiofrequency tissue tagging to diagnose constrictive pericarditis and compared results with surgical findings and cardiac catheterization. In 16 patients who underwent pericardiectomy, CMR positivity agreed 100% with intraoperative…