Archive

621 posts

Showing results for: Cu

[Effect of microwave radiation on primary cultured Sertoli cells].

Research RF Safe Research Library Jan 1, 2009

This in vitro study exposed primary cultured Sertoli cells to microwave radiation at 0, 30, or 100 mW/cm^2 for 5 minutes and assessed outcomes 6 hours later. The authors report no differences in apoptosis/death or intracellular Ca2+ at 30 mW/cm^2, though cell-cycle distribution shifted. At 100 mW/cm^2, intracellular…

[A preliminary study on role of acid sphingomyelinase in receptor clustering induced by 50-Hz magnetic fields].

Research RF Safe Research Library Jan 1, 2009

This in vitro study exposed human amnion (FL) cells to a 50-Hz sinusoidal magnetic field (0.4 mT) for 15 minutes and assessed epidermal growth factor receptor (EGFR) clustering. The authors report that magnetic field exposure induced EGFR clustering, and that this effect was blocked by imipramine, an acid…

Effects of mobile phone use on specific intensive care unit devices.

Research RF Safe Research Library Jan 1, 2008

This study tested electromagnetic interference from GSM and CDMA mobile phones placed one foot from ICU devices (syringe pump, mechanical ventilator, bedside monitor) in off, standby, and talk modes. EMI was observed for the syringe pump in talk mode, with a mean 2.66 ml variation between calculated and delivered…

Head-to-head comparison of coronary plaque evaluation between multislice computed tomography and intravascular ultrasound radiofrequency data analysis.

Research RF Safe Research Library Jan 1, 2008

This study compared coronary plaque assessment by 64-slice multislice computed tomography (MSCT) with virtual histology intravascular ultrasound (VH IVUS) in 50 patients. The Agatston score on MSCT correlated moderately with calcium volume measured by VH IVUS, and MSCT plaque categories broadly reflected differences…

Apparent violation of the Wiedemann-Franz law near a magnetic field tuned metal-antiferromagnetic quantum critical point.

Research RF Safe Research Library Jan 1, 2008

This paper reports calculations of interlayer electrical and thermal resistivity in a layered metal assuming Fermi-liquid quasiparticles inelastically scattered by two-dimensional antiferromagnetic spin fluctuations. The model yields linear-in-temperature behavior over a broad range and suggests that extrapolations…

[Effect of 1.8 GHz radiofrequency electromagnetic fields on gene expression of rat neurons].

Research RF Safe Research Library Jan 1, 2008

This in vitro study exposed primary cultured rat neurons to 1.8 GHz RF-EMF at an average SAR of 2 W/kg and assessed gene expression changes. The authors report multiple differentially expressed genes after 24 h intermittent exposure and confirm exposure-dependent changes in Egr-1, Mbp, and Plp by semi-quantitative…

Health hazards of mobile phones: an Indian perspective.

Research RF Safe Research Library Jan 1, 2008

This review-style article provides an overview of mobile phone radiation exposure in India and discusses potential health hazards in terms of thermal and non-thermal effects. It states that usage behaviors such as longer call duration and predominantly one-sided use are described as key risks increasing the…

Numerical methods for computing the ground state of spin-1 Bose-Einstein condensates in a uniform magnetic field.

Research RF Safe Research Library Jan 1, 2008

This paper presents numerical methods to compute ground-state solutions of spin-1 Bose-Einstein condensates in a uniform magnetic field. The approach uses normalized gradient flow with an additional normalization condition and enforces conservation of total mass and magnetization. The authors compare numerical…

Effect of temperature (-5 to 130 degrees C) and fiber direction on the dielectric properties of beef Semitendinosus at radio frequency and microwave frequencies.

Research RF Safe Research Library Jan 1, 2008

This study measured dielectric properties of beef Semitendinosus across 27, 915, and 1800 MHz and temperatures from -5 to 130 °C using an open-ended coaxial probe. The results indicate that frequency, temperature, and muscle fiber orientation influence dielectric constant, dielectric loss, and calculated penetration…

Adverse effects of excessive mobile phone use.

Research RF Safe Research Library Jan 1, 2008

This cross-sectional questionnaire study surveyed 286 medical students about mobile phone use and health complaints. The abstract reports multiple self-reported symptoms (including impaired concentration, memory disturbances, sleeplessness, fatigue, and headache) and notes that 44.4% of respondents attributed their…

Influence of mashed potato dielectric properties and circulating water electric conductivity on radio frequency heating at 27 MHz.

Research RF Safe Research Library Jan 1, 2008

This engineering study used experiments, computer simulations, and simplified analytical calculations to examine how mashed potato dielectric properties and circulating water electrical conductivity affect RF heating at 27 MHz. The authors report that higher circulating water conductivity and higher salt content in…

Intestinal MMC-related electric fields and pancreatic juice control the adhesion of Gram-positive and Gram-negative bacteria to the gut epithelium--in vitro study.

Research RF Safe Research Library Jan 1, 2008

This in vitro study tested whether a weak electric field reconstructed from duodenal spiking potentials during an MMC cycle affects bacterial adhesion to Caco-2 intestinal epithelial cells. The MMC-related electric field increased adhesion of Lactobacillus and Lactococcus strains, while two pathogenic strains…

Electronic response properties of carbon nanotubes in magnetic fields.

Research RF Safe Research Library Jan 1, 2008

This computational study investigates magnetic linear response properties of achiral and chiral carbon nanotubes using first-principles electronic structure methods. It computes magnetic shielding inside and outside nanotubes due to electronic currents induced by external magnetic fields applied parallel or…

Greyscale intravascular ultrasound and IVUS-radiofrequency tissue characterisation to improve understanding of the mechanisms of coronary stent thrombosis in drug-eluting stents.

Research RF Safe Research Library Jan 1, 2008

This review describes proposed mechanical causes of drug-eluting stent thrombosis and notes that many are identifiable by greyscale intravascular ultrasound (IVUS). It highlights that evidence linking specific IVUS findings to stent thrombosis remains uncertain because relatively few stent thrombosis cases have been…

Plasma-assembled carbon nanotubes: electric field-related effects.

Research RF Safe Research Library Jan 1, 2008

This engineering-focused paper compares carbon nanotube growth in dense low-temperature plasma versus on a substrate surface using hybrid/Monte-Carlo simulations. It reports that plasma parameters strongly influence ion fluxes and nanotube growth kinetics, with large differences in growth rates and fluxes between…

Improvement in magnetic field immunity of externally-coupled transcutaneous energy transmission system for a totally implantable artificial heart.

Research RF Safe Research Library Jan 1, 2008

This engineering study addresses interference between induction-heating cookers and an externally coupled transcutaneous energy transmission system for a totally implantable artificial heart. The authors report that magnetic flux from an IH cooker can couple into the TET transformer and affect system performance. A…

[Microstrip antenna design and system research of radio frequency identification temperature sensor].

Research RF Safe Research Library Jan 1, 2008

This engineering paper introduces an RFID sensor network concept integrating RFID with wireless sensor networks and emphasizes the role of antennas. It discusses coil, dipole, and microstrip antennas and reports designing a microstrip antenna for a wireless temperature monitoring and control system. Measurements are…

Minimal-SAR RF pulse optimization for parallel transmission in MRI.

Research RF Safe Research Library Jan 1, 2008

This engineering study presents an optimization framework to design RF pulses for parallel transmission MRI with the goal of minimizing SAR. Using computer simulations of a 4-channel system, the authors report significant SAR reduction while maintaining excitation pattern quality and without increasing pulse…

Coil design considerations for deep-brain transcranial magnetic stimulation (dTMS).

Research RF Safe Research Library Jan 1, 2008

This engineering-focused conference paper proposes figures of merit to evaluate deep-brain transcranial magnetic stimulation (dTMS) coil designs, focusing on depth penetration, scalp stimulation, focality, and energy. It analyzes circular crown and C-core coils and reports reduced electric-field attenuation with…

New functions developed for ICU/CCU remote monitoring system using a 3G mobile phone and evaluations of the system.

Research RF Safe Research Library Jan 1, 2008

This conference paper describes development of new functions for an ICU/CCU remote monitoring system that uses a 3G mobile phone. The authors state that evaluations were performed on several different mobile phones and suggest the system has accuracy and real-time performance suitable for hospital adoption. The…

Single access point localisation for wearable wireless sensors.

Research RF Safe Research Library Jan 1, 2008

This engineering conference paper describes a single access point method for localizing a subject using RF signals from wearable wireless sensors. The approach combines RSSI and LQI measurements from one basestation and applies filtering. The abstract reports that accuracy can approach that of multi-basestation…

Radiofrequency dosimetry in subjects implanted with metallic straight wires: a numerical study.

Research RF Safe Research Library Jan 1, 2008

This numerical FDTD study modeled RF exposure at 900 and 1800 MHz in tissue containing thin metallic straight wire implants. The model indicates that the wire can substantially increase local SAR, creating high SAR gradients. Despite this, the authors report that exposures below current safe levels resulted in…

Combined effect of temperature and pulsed electric fields on apple juice peroxidase and polyphenoloxidase inactivation.

Research RF Safe Research Library Jan 1, 2008

This laboratory study evaluated pulsed electric fields (PEF) combined with preheating to inactivate peroxidase (POD) and polyphenoloxidase (PPO) in freshly prepared apple juice. The highest reported inactivation occurred with preheating to 50°C and PEF at 40 kV/cm for 100 μs, exceeding the reductions seen with…

Position-independent chemical quantitation with passive 13.56-MHz radio frequency identification (RFID) sensors.

Research RF Safe Research Library Jan 1, 2008

This engineering study evaluates whether passive 13.56-MHz RFID-based chemical sensors can quantify analytes reliably despite repositioning errors between the sensor and pickup coil. Using simultaneous measurement of multiple complex-impedance parameters and multivariate statistical analysis, the authors report…

In-line application of electric field in capillary separation systems: Joule heating, pH and conductivity.

Research RF Safe Research Library Jan 1, 2008

This engineering study investigated factors affecting current when an electric field is applied in-line in a capillary separation system. Temperature measurements and a replicated cooling setup were used to estimate Joule heating effects, which were reported to be relatively small. In contrast, significant pH shifts…

← Prev Page 24 / 25 Next →