Archive

583 posts

Showing results for: SA

Influence of pulsed electric field treatments on the volatile compounds of milk in comparison with pasteurized processing.

Research RF Safe Research Library Jan 1, 2011

The paper evaluates how pulsed electric field (PEF) processing affects milk volatile compounds compared with HTST pasteurization (75 °C, 15 s). GC-MS detected 37 volatiles and reported some compositional differences between PEF and pasteurized milk, including increased aldehydes and lower methyl ketones with PEF.…

Reduction of implant RF heating through modification of transmit coil electric field.

Research RF Safe Research Library Jan 1, 2011

This engineering study describes modifying MRI RF transmit coil electric-field distributions to create electric field-free zones without substantially changing transmit sensitivity. Phantom experiments are reported to show reduced implant heating when a zero electric-field plane is aligned with the implant location.…

Transient and steady-state magnetic fields induce increased fluorodeoxyglucose uptake in the rat hindbrain.

Research RF Safe Research Library Jan 1, 2011

This animal PET study examined whether a weak 60-Hz magnetic field alters brain glucose utilization in rats. The abstract reports increased FDG uptake in hindbrain voxels when a 2.5-G field was oriented orthogonally to the sagittal plane, but not when field direction varied randomly. Distinct activation effects were…

Human keratinocytes in culture exhibit no response when exposed to short duration, low amplitude, high frequency (900 MHz) electromagnetic fields in a reverberation chamber.

Research RF Safe Research Library Jan 1, 2011

This in vitro study exposed normal human epidermal keratinocytes to non-thermal 900 MHz electromagnetic fields in a mode-stirred reverberation chamber under two short-duration conditions. Microarray analysis found only limited gene modulation (20 genes) with small expression ratios and no shared genes across…

Effects of low frequency electromagnetic fields on the chondrogenic differentiation of human mesenchymal stem cells.

Research RF Safe Research Library Jan 1, 2011

This in vitro study examined whether extremely low-frequency magnetic fields affect chondrogenic differentiation of human mesenchymal stem cells in pellet culture. Cells exposed for 3 weeks to a homogeneous sinusoidal 5 mT magnetic field showed increased collagen type II expression (significant at passage 6) and…

Evaluation of magnetic resonance safety of veterinary radiofrequency identification devices at 1 T.

Research RF Safe Research Library Jan 1, 2011

This study evaluated MRI safety parameters for three commercial veterinary RFID microchips at 1 T, assessing movement forces, heating, artifacts, and device function. Translation and torque were reported to be larger than expected from normal activity, but no significant heating was observed and microchip function…

A rapid and facile synthesis of nanofibrillar polyaniline using microwave radiation.

Research RF Safe Research Library Jan 1, 2010

This engineering study describes a microwave-assisted method to synthesize polyaniline (PANI) nanofibers. Reported yields under microwave irradiation were similar to conventional synthesis but achieved in minutes rather than hours. Structural and morphological characterization (FTIR, Raman, SEM, TEM) reportedly…

Electrooptical effects in colloid systems subjected to short pulses of strong electric field.

Research RF Safe Research Library Jan 1, 2010

This study describes an electrooptical technique for polydisperse colloid solutions using short pulses of strong sine-shaped electric field, intended for systems that cannot withstand prolonged field exposure. The authors report that key particle parameters can still be extracted from the resulting experimental data.…

High magnetic field induced charge density waves and sign reversal of the Hall coefficient in graphite.

Research RF Safe Research Library Jan 1, 2010

This condensed-matter study investigates highly oriented pyrolytic graphite under very strong magnetic fields at low temperature. It reports a magnetic-field-induced charge density wave transition and a subsequent sign reversal of the Hall coefficient from negative to positive. The reported angular dependence…

Surface superconducting states in a yttrium hexaboride single crystal in a tilted magnetic field.

Research RF Safe Research Library Jan 1, 2010

This experimental study examined nucleation of superconductivity at the surface of a single-crystal yttrium hexaboride (YB6) in a tilted dc magnetic field. The authors measured Hc3 on each side of the sample as a function of the angle between the field and the surface. They report Hc3/Hc2 ≈ 1.28 for a perpendicular…

Radiofrequency microtenotomy for the treatment of plantar fasciitis shows good early results.

Research RF Safe Research Library Jan 1, 2010

This small clinical case series evaluated TOPAZ radiofrequency coblation microtenotomy for recalcitrant plantar fasciitis in 14 patients. The abstract reports improved AOFAS hindfoot scores at 3 and 6 months and improvements in several SF-36 domains, with most patients reporting good-to-excellent satisfaction. The…

Pedestrians, vehicles, and cell phones.

Research RF Safe Research Library Jan 1, 2010

This study used an immersive virtual environment to examine how divided attention affects pedestrian street-crossing performance. Thirty-six participants crossed virtual streets while undistracted, conversing hands-free on a cell phone, or listening to music. Cell phone conversation was associated with a lower…

In vitro tests reveal sample radiofrequency identification readers inducing clinically significant electromagnetic interference to implantable pacemakers and implantable cardioverter-defibrillators.

Research RF Safe Research Library Jan 1, 2010

This in vitro study tested electromagnetic compatibility between passive RFID readers and 15 pacemakers plus 15 ICDs across 134 kHz, 13.56 MHz, and 915 MHz bands. EMI reactions were common with low-frequency RFID and rare with high-frequency RFID, while no reactions were observed with ultra-high-frequency or…

Electromagnetic fields and DNA damage

Research RF Safe Research Library Jan 1, 2009

This review discusses the comet assay and summarizes research on non-ionizing EMF exposure and DNA/chromosomal damage. It describes both positive and negative findings across studies, noting no consistent overall pattern for radiofrequency radiation (RFR). The authors nonetheless conclude that under certain exposure…

[Treatment of benign prostatic hyperplasia by radiofrequency (TUNA): a monocentric study of 28 cases treated in ambulatory surgery].

Research RF Safe Research Library Jan 1, 2009

This monocentric study evaluated outpatient feasibility and outcomes of radiofrequency transurethral needle ablation (TUNA) for benign prostatic hyperplasia in patients who did not respond to medical therapy. In the outpatient subgroup, urinary symptom scores, quality of life, flow measures, and residual urine…

The use of pulsed radiofrequency treatment for chronic benign pancreatitis pain.

Research RF Safe Research Library Jan 1, 2009

This paper reports on pulsed radiofrequency treatment as an interventional approach for pain due to chronic benign pancreatitis. The authors describe their experience in two patients and characterize the technique as minimally neurodestructive and potentially able to reduce pain perception by altering nerve…

The use of a standard radiofrequency energy delivery system to facilitate transseptal puncture.

Research RF Safe Research Library Jan 1, 2009

This paper describes a procedural technique for transseptal puncture that uses brief pulses of radiofrequency energy delivered from a standard electrosurgical cautery generator through the needle tip. The approach is presented as a way to facilitate septal traversal when tissue is elastic, aneurysmal, or thickened,…

Are people living next to mobile phone base stations more strained? Relationship of health concerns, self-estimated distance to base station, and psychological parameters.

Research RF Safe Research Library Jan 1, 2009

This cross-sectional study surveyed 57 participants about perceived proximity to mobile phone base stations, EMF-related concerns, and psychological strain, and also collected saliva biomarkers. Self-declared base station neighbors (≤100 m) showed higher salivary alpha-amylase and higher symptom checklist scores on…

Spatial and Temporal Variations of a Screening Current Induced Magnetic Field in a Double-Pancake HTS Insert of an LTS/HTS NMR Magnet.

Research RF Safe Research Library Jan 1, 2009

This engineering study measures and simulates screening current induced magnetic fields (SCF) in a Bi2223-tape HTS insert used in an LTS/HTS NMR magnet at 77 K. SCF was induced by the insert self-field, an external 5-T background magnet, and their combination, and axial field distributions and temporal variations…

Sham Transcranial Magnetic Stimulation Using Electrical Stimulation of the Scalp.

Research RF Safe Research Library Jan 1, 2009

This study describes development and validation of a sham rTMS approach that combines a matched sham coil (for look/sound) with scalp electrical stimulation (for sensation). In back-to-back comparisons, TMS-naïve participants reportedly could not tell active from sham, whereas experienced participants could. The…

Mobile phone technology for children with type 1 and type 2 diabetes: a parent survey.

Research RF Safe Research Library Jan 1, 2009

This cross-sectional web-based survey assessed parents' concerns about managing their children's diabetes and their attitudes toward a mobile-phone-integrated glucometer service that could transmit real-time glucose readings. Parents most commonly reported concerns about access to their child's health care provider,…

[Effects of 50 Hz sinusoidal magnetic field on Ca2+ release channel ryanodine receptor of sarcoplasmic reticulum vesicles].

Research RF Safe Research Library Jan 1, 2009

This in vitro study examined whether a 50 Hz sinusoidal magnetic field affects the sarcoplasmic reticulum calcium release channel RyR1. A 0.4 mT exposure for 30 minutes increased SR Ca2+ release rate and [(3)H]-ryanodine binding under NADH/NAD+ conditions. The authors also report increased NADH oxidation and…

[Conclusion: probable and possible futures. MRI with ultra high magnetic field].

Research RF Safe Research Library Jan 1, 2009

This narrative piece states that MR neuroimaging does not interfere with brain function and is safe for use in patients and healthy volunteers. It argues that ultra-high-field MRI could substantially improve spatiotemporal resolution, potentially enabling study of brain function at finer scales. It also describes the…

Static magnetic field therapy: a critical review of treatment parameters.

Research RF Safe Research Library Jan 1, 2009

This critical review summarizes human research on static magnetic field (SMF) therapy delivered by permanent magnets attached to the skin and evaluates how well studies report SMF dosage and treatment parameters. Across 56 included studies, many did not report essential SMF characteristics (e.g., magnet dimensions,…

Biological effects from electromagnetic field exposure and public exposure standards

Research RF Safe Research Library Jan 1, 2008

This review describes public concerns and scientific reports of non-thermal biological effects from low-intensity ELF and RF exposures. It lists multiple health endpoints reported to be associated with ELF and/or RF and highlights the BioInitiative Report’s conclusion that a reasonable suspicion of risk exists at…

← Prev Page 22 / 24 Next →