Advanced Radio Frequency Applicators for Thermal Magnetic Resonance Theranostics of Brain Tumors.
Research
RF Safe Research Library
Jan 1, 2023
This engineering/simulation study evaluates RF applicator array designs for Thermal Magnetic Resonance (ThermalMR), which combines MRI with RF hyperthermia for brain tumor theranostics. Using EMF and temperature simulations at 7.0 T, 9.4 T, and 10.5 T, hybrid loop+SGBT dipole arrays are reported to provide superior…
Numerical Modeling and Computer Simulation of a Meander Line Antenna for Alzheimer's Disease Treatment, a Feasibility Study.
Research
RF Safe Research Library
Jan 1, 2023
This feasibility study reports numerical modeling and HFSS simulations of a portable meander line antenna intended to deliver repeated electromagnetic field stimulation at 64 MHz for potential Alzheimer's disease treatment. Using two numerical head phantoms, the authors simulated E/H fields and SAR with a 50-W input…
The effects of RF coils and SAR supervision strategies for clinically applicable nonselective parallel-transmit pulses at 7 T.
Research
RF Safe Research Library
Jan 1, 2023
This engineering study evaluated how different 7T parallel-transmit head coils and SAR supervision strategies affect nonselective pTx pulse design for a 3D-MPRAGE sequence. It reports that FOCUS pulses were more robust than universal pulses when applied across different coils, and that FOCUS inversion pulses…
An Out-of-Phase Wireless Power Transfer System for Implantable Medical Devices to Reduce Human Exposure to Electromagnetic Field and Increase Power Transfer Efficiency.
Research
RF Safe Research Library
Jan 1, 2022
This engineering study proposes an out-of-phase coupled wireless power transfer system for implantable medical devices intended to reduce electromagnetic field exposure in the tissue region between transmitting and receiving coils. The authors report, via simulation and measurements, lower EMF and higher power…
EMF Antenna Exposure on a Multilayer Human Head Simulation for Alzheimer Disease Treatments.
Research
RF Safe Research Library
Jan 1, 2022
This study uses HFSS/EMPro simulations to model a 64 MHz antenna exposure on a multilayer human head to match parameters previously used in neuronal culture experiments. The simulations report achieving up to 0.6 W/kg maximum SAR and approximately 0.4–0.6 W/kg across head layers with a 1 A peak current pulse. The…
Magnetic characterization of Mumetal® for passive shielding of stray fields down to the nano-Tesla level
Research
RF Safe Research Library
Feb 1, 2021
This engineering study addresses stray magnetic fields as a performance-limiting imperfection for the Compact Linear Collider (CLIC), where simulations indicate sensitivity to fields on the order of 0.1 nT. It presents DC and AC magnetic characterization of two Mumetal® samples (annealed in final form vs…
Translocation of silica nanospheres through giant unilamellar vesicles (GUVs) induced by a high frequency electromagnetic field.
Research
RF Safe Research Library
Jan 1, 2021
This in vitro study used giant unilamellar vesicles (GUVs) to examine effects of an 18 GHz electromagnetic field on membrane behavior. The authors report increased membrane permeability after exposure, inferred from internalisation of 23.5 nm hydrophilic silica nanospheres. Complementary molecular dynamics…
Towards Environmental RF-EMF Assessment of mmWave High-Node Density Complex Heterogeneous Environments.
Research
RF Safe Research Library
Jan 1, 2021
This paper presents an RF-EMF exposure assessment combining measurements and deterministic 3D ray-launching simulations in a large indoor public library with high node density. It considers mmWave 5G FR2 at 28 GHz and Wi-Fi 802.11ay at 60 GHz under realistic operation conditions with varying user distributions. The…
Radiofrequency applicator concepts for thermal magnetic resonance of brain tumors at 297 MHz (7.0 Tesla).
Research
RF Safe Research Library
Jan 1, 2020
This engineering/simulation study evaluates RF applicator concepts for ThermalMR brain tumor heating at 297 MHz (7.0 Tesla) using clinically realistic GBM-based models. EMF simulations compared 10 applicator designs and two SAR-based planning algorithms for small and large target volumes. Power-focused optimization…
Evaluation of MRI RF electromagnetic field induced heating near leads of cochlear implants.
Research
RF Safe Research Library
Jan 1, 2018
This simulation study evaluated RF-induced heating near cochlear implant leads during 1.5 T MRI using a transfer function method. Across studied configurations, the average temperature rise was 0.79 °C and the maximum was 2.80 °C at a whole-body average SAR of 2 W/kg. The authors report that lead trajectory and MRI…
Influence of the on-line ELF-EMF stimulation on the electrophysiological properties of the rat hippocampal CA1 neurons in vitro.
Research
RF Safe Research Library
Jan 1, 2017
This paper describes an on-line ELF magnetic stimulation setup and evaluates coil field distribution using COMSOL simulations alongside physical measurements. The authors report that modeled and measured magnetic flux densities were similar, and that stimulation induced sodium channel currents and fEPSPs in rat…
Antenna Design and SAR Analysis on Human Head Phantom Simulation for Future Clinical Applications.
Research
RF Safe Research Library
Jan 1, 2017
This study developed a mathematical and computer simulation model to analyze RF-EMF exposure in a human head phantom, motivated by potential therapeutic applications. The modeled exposure used a Yagi-Uda antenna at 64 MHz with SAR 0.6 W/kg and compared field distribution using one versus four antennas. COMSOL Bioheat…
The effects of human height and mass on the calculated induced electric fields at 50 Hz for comparison with the EMF Directive 2013/35/EU.
Research
RF Safe Research Library
Jan 1, 2017
This computational study examined how human height and mass influence calculated induced electric fields in the body from external 50 Hz electric and magnetic fields. Anatomically realistic human models derived from the MAXWEL phantom were varied across a range of heights and masses and used to simulate induced…
Radio frequency induced heating of an insulated wire during magnetic resonance imaging.
Research
RF Safe Research Library
Jan 1, 2016
This engineering study investigated RF-induced power deposition near straight insulated leads in an MRI context under different incident electric field profiles. Using 3-D electromagnetic simulations, the authors compared simulation-derived power deposition with implant model predictions. For the setups examined,…
An innovative therapy for peri-implantitis based on radio frequency electric current: numerical simulation results and clinical evidence.
Research
RF Safe Research Library
Jan 1, 2016
This conference paper describes a peri-implantitis therapy using radio frequency electric current and presents numerical simulations alongside referenced clinical evidence. The abstract reports 81% successful treatment across 66 implants in 46 patients. FEM modeling suggests current preferentially concentrates in…
Design, simulation and evaluation of uniform magnetic field systems for head-free eye movement recordings with scleral search coils.
Research
RF Safe Research Library
Jan 1, 2016
This conference paper describes the design and simulation of coil geometries intended to produce a highly uniform magnetic field for scleral search coil eye-movement recordings without restricting head motion. The authors built a large (2.2 m per side) coil frame and compared measured magnetic flux density to…
Measurement and Modeling of Personal Exposure to the Electric and Magnetic Fields in the Vicinity of High Voltage Power Lines.
Research
RF Safe Research Library
Jan 1, 2016
This study reports experimental measurements and numerical modeling of electric and magnetic fields near a high voltage substation in Annaba, Algeria. Field intensities were measured at multiple heights intended to correspond to sensitive human body regions and were validated using finite element simulations. The…
Sweeping of hydrophobic amines under inhomogeneous electric field and low surfactant concentration in micellar electrokinetic chromatography.
Research
RF Safe Research Library
Jan 1, 2016
This laboratory/analytical study examined how sample matrix affects sample sweeping in micellar electrokinetic chromatography under an inhomogeneous electric field. It reports strong focusing for hydrophobic cationic analytes when the sample matrix conductivity is much higher than the BGE, even with low surfactant…
Effects of Anatomical Differences on Electromagnetic Fields, SAR, and Temperature Change.
Research
RF Safe Research Library
Jan 1, 2016
This engineering study evaluates how anatomical/geometric differences affect MRI RF safety metrics. Simulations and a bovine-phantom experiment found that similar transmit B-field patterns can coincide with notably different peak SAR and temperature rise. The authors highlight challenges in using…
Near-field radiofrequency electromagnetic exposure assessment
Research
RF Safe Research Library
Jan 1, 2015
This paper presents a near-field RF exposure assessment method comparing standard SAR estimation from E-field measurements in tissue-simulating liquid with a proposed approach based on incident H-field measurements. Experiments were conducted at 900, 1800, and 2450 MHz using dipole antennas and a flat phantom, with…
Toward a Quantitative Understanding of the Electric Field in Thermal Metal Oxidation and a Self-Consistent Wagner Theory.
Research
RF Safe Research Library
Jan 1, 2014
This engineering/physical chemistry study develops an analytical model and uses computer simulations to describe the electric field in oxide films during thermal metal oxidation. It reports that the electrostatic potential drop across the bulk oxide is often limited to about kBT/e, suggesting most of a larger overall…
Electric field enhancement and far-field radiation pattern of the nanoantenna with concentric rings.
Research
RF Safe Research Library
Jan 1, 2014
This engineering study evaluates a nanoantenna design that combines concentric gold rings with a directivity-enhanced Raman scattering structure. Using finite-difference time-domain simulations and SERS measurements on fabricated devices with thiophenol, the authors report stronger electric field enhancement,…
[Study of the influence of uniform transverse magnetic field on the dose distribution of high energy electron beam using Monte Carlo method].
Research
RF Safe Research Library
Jan 1, 2014
This engineering/medical physics study used Monte Carlo simulations to examine how a uniform transverse magnetic field affects the dose distribution of a 30 MeV electron beam in a water phantom. The abstract reports substantial changes in depth-dose, including reduced range and a pronounced end-of-range dose peak…
Dielectric aggregation kinetics of cells in a uniform AC electric field.
Research
RF Safe Research Library
Jan 1, 2014
This study develops and tests a theoretical model of how HeLa cells aggregate when exposed to a uniform AC electric field. Model-derived aggregation times and predicted string-length growth rates matched numerical simulation, and experiments observed substantial clustering in the chamber. The work is framed as…
Molecular dynamics study of response of liquid N,N-dimethylformamide to externally applied electric field using a polarizable force field.
Research
RF Safe Research Library
Jan 1, 2014
This molecular dynamics simulation study examined liquid N,N-dimethylformamide exposed to uniform external electric fields from 0.001 to 1 V/nm using an extended AMOEBA polarizable force field. The authors report that fields above 0.01 V/nm significantly altered the liquid’s structure and a range of molecular and…