Archive

476 posts

Showing results for: CoMP

The effect of MRET polymer compound on SAR values of RF phones.

Research RF Safe Research Library Jan 1, 2008

This article describes a hypothesis and experimental testing of an MRET polymer compound applied to RF phones. It reports increased dielectric permittivity in water-based solutions and reduced SAR values in a tissue-simulating phantom head. It also reports no significant change in air measurements of phone signals,…

SAR changes in a human head model for plane wave exposure (500 - 2500 MHz) and a comparison with IEEE 2005 safety limits.

Research RF Safe Research Library Jan 1, 2008

This engineering/modeling study derived external electric field values from peak average 10 g SAR in a realistic human head model exposed to plane waves at 500–2500 MHz. The derived fields were compared with IEEE and ICNIRP reference levels across multiple incident directions and polarizations. The authors report…

Influence of mashed potato dielectric properties and circulating water electric conductivity on radio frequency heating at 27 MHz.

Research RF Safe Research Library Jan 1, 2008

This engineering study used experiments, computer simulations, and simplified analytical calculations to examine how mashed potato dielectric properties and circulating water electrical conductivity affect RF heating at 27 MHz. The authors report that higher circulating water conductivity and higher salt content in…

Electronic response properties of carbon nanotubes in magnetic fields.

Research RF Safe Research Library Jan 1, 2008

This computational study investigates magnetic linear response properties of achiral and chiral carbon nanotubes using first-principles electronic structure methods. It computes magnetic shielding inside and outside nanotubes due to electronic currents induced by external magnetic fields applied parallel or…

Greyscale intravascular ultrasound and IVUS-radiofrequency tissue characterisation to improve understanding of the mechanisms of coronary stent thrombosis in drug-eluting stents.

Research RF Safe Research Library Jan 1, 2008

This review describes proposed mechanical causes of drug-eluting stent thrombosis and notes that many are identifiable by greyscale intravascular ultrasound (IVUS). It highlights that evidence linking specific IVUS findings to stent thrombosis remains uncertain because relatively few stent thrombosis cases have been…

Plasma-assembled carbon nanotubes: electric field-related effects.

Research RF Safe Research Library Jan 1, 2008

This engineering-focused paper compares carbon nanotube growth in dense low-temperature plasma versus on a substrate surface using hybrid/Monte-Carlo simulations. It reports that plasma parameters strongly influence ion fluxes and nanotube growth kinetics, with large differences in growth rates and fluxes between…

Minimal-SAR RF pulse optimization for parallel transmission in MRI.

Research RF Safe Research Library Jan 1, 2008

This engineering study presents an optimization framework to design RF pulses for parallel transmission MRI with the goal of minimizing SAR. Using computer simulations of a 4-channel system, the authors report significant SAR reduction while maintaining excitation pattern quality and without increasing pulse…

Coil design considerations for deep-brain transcranial magnetic stimulation (dTMS).

Research RF Safe Research Library Jan 1, 2008

This engineering-focused conference paper proposes figures of merit to evaluate deep-brain transcranial magnetic stimulation (dTMS) coil designs, focusing on depth penetration, scalp stimulation, focality, and energy. It analyzes circular crown and C-core coils and reports reduced electric-field attenuation with…

Development of a cell phone-based video streaming system for persons with early stage Alzheimer's disease.

Research RF Safe Research Library Jan 1, 2008

This conference paper reports early development of a cell phone-based video streaming system to deliver video reminders for people with early dementia. Carers can record and schedule reminders remotely via a computer and webcam. A first prototype was implemented, with an initial field trial scheduled and a larger…

Electromagnetic interference to infusion pumps. Update2008 from GSM mobile phones.

Research RF Safe Research Library Jan 1, 2008

This engineering study updates a prior (2005) survey on electromagnetic interference (EMI) affecting infusion pumps and extends testing to DECT phones and WiFi terminals. It reports a reduced failure rate for GSM phone exposure compared with 2005 (58% to 30%). The authors report that WiFi and DECT did not pose a real…

Position-independent chemical quantitation with passive 13.56-MHz radio frequency identification (RFID) sensors.

Research RF Safe Research Library Jan 1, 2008

This engineering study evaluates whether passive 13.56-MHz RFID-based chemical sensors can quantify analytes reliably despite repositioning errors between the sensor and pickup coil. Using simultaneous measurement of multiple complex-impedance parameters and multivariate statistical analysis, the authors report…

A benzene-core trinuclear GdIII complex: towards the optimization of relaxivity for MRI contrast agent applications at high magnetic field.

Research RF Safe Research Library Jan 1, 2008

This chemistry/engineering study reports the synthesis and NMR/MRI-relevant characterization of a trinuclear Gd(III) chelate intended for high-field MRI contrast applications. Using 17O NMR and proton relaxivity across multiple fields and temperatures, the authors infer bishydration, quantify water exchange and…

Effects of extremely low frequency electromagnetic fields on testes in guinea pig.

Research RF Safe Research Library Jan 1, 2007

This animal study exposed 36 adult male guinea pigs to extremely low frequency electromagnetic fields at 5 Hz or 50 Hz and compared testosterone and testes tissue outcomes with sham/control conditions. After 5 days, the authors report a significant decrease in testosterone in exposed groups versus controls. They also…

Effects of electromagnetic field produced by mobile phones on the oxidant and antioxidant status of rats.

Research RF Safe Research Library Jan 1, 2007

This rat study examined whether EMR from GSM mobile phones affects oxidant/antioxidant status. Compared with controls, exposed rats had lower plasma antioxidant vitamins (C, E, A), reduced glutathione, and lower CAT and SOD activities. The acute exposure condition was reported to produce larger decreases than the…

Exposure to an additional alternating magnetic field affects comb building by worker hornets.

Research RF Safe Research Library Jan 1, 2007

This animal study reports that exposing worker oriental hornets in an artificial breeding box to an additional 50 Hz magnetic field (50–70 mGauss) altered comb construction compared with controls under only the terrestrial magnetic field. The abstract describes fewer cells and eggs, more deformed cell geometry, and…

[Measurements of professional exposure to ELF fields in some production areas within the territory of Regione Campania and comparison with the action values according to 2004/40/CE Directive].

Research RF Safe Research Library Jan 1, 2007

This occupational exposure assessment measured ELF magnetic fields in 400 workers across 80 work areas in several production sectors in Regione Campania. Measurements were taken continuously over two shifts and processed into RMS magnetic-field values. The authors report no exceedance of the EU 2004/40/CE action…

[Assessment of radiofrequency electromagnetic fields levels in the Taranto area].

Research RF Safe Research Library Jan 1, 2007

This study reports punctual monitoring of RF electromagnetic fields from radiobase stations in the Taranto area, with measurement campaigns conducted from November 2005 to March 2007. Measurements covered 108 transmitting stations across multiple communication technologies within 100 kHz to 3 GHz. Most monitored…

[ELF-MF occupational exposure: repeated measures on workers].

Research RF Safe Research Library Jan 1, 2007

This occupational exposure assessment used personal dosimeters to estimate ELF magnetic field exposure in 543 workers across 9 occupational settings in Emilia-Romagna. Median time-weighted average exposure was 0.14 microT, with tile production showing the highest setting-level TWA. Repeat measurements after 6–9…

[Evaluation of the genotoxicity of the extremely low frequency-magnetic fields (ELF-MF) in workers exposed for professional reasons].

Research RF Safe Research Library Jan 1, 2007

This occupational study assessed whether extremely low frequency magnetic fields (ELF-MF) are associated with genotoxicity using cytogenetic assays in 109 workers. Comparisons across exposure strata, including a highest-exposed subgroup (TWA > 1 microT), found no significant differences in CA, SCE, or MN outcomes.…

Use of radiofrequency hepatic parenchymal transection device in hepatic hemangioma resection: early experience and lessons learned.

Research RF Safe Research Library Jan 1, 2007

This retrospective case series reviewed four resections of symptomatic giant cavernous hepatic hemangiomas using an RF-powered multiarray (Habib sealer) for hepatic parenchymal transection. No blood transfusions were required and no major biliary or vascular injuries were observed at 1-year follow-up; one…

Comparison of the effects of continuous and pulsed mobile phone like RF exposure on the human EEG.

Research RF Safe Research Library Jan 1, 2007

This study tested whether GSM-like RF exposure affects resting human EEG, focusing on alpha band power and non-linear EEG features. Using a fully counterbalanced cross-over design with 12 participants and a dipole antenna intended to better resemble handset exposure, the authors found no changes after 15 minutes of…

Magnetic field distribution and signal decay in functional mri in very high fields (up to 9.4 T) using monte carlo diffusion modeling.

Research RF Safe Research Library Jan 1, 2007

This paper models extravascular MRI signal decay (R2/R2*) as a function of blood oxygenation, vessel geometry, and magnetic field strength up to 9.4 T using Monte Carlo diffusion simulations. It reports different vessel-size dependencies for Hahn-spin-echo versus gradient-recalled-echo relaxation across field…

Magnetic field switching between the two orbital-ordered states in DyVO3.

Research RF Safe Research Library Jan 1, 2007

This Physical Review Letters study investigates phase competition between spin- and orbital-ordered states in a DyVO3 single crystal. The abstract reports reentrant temperature-driven transitions in spin ordering and orbital ordering. It also reports that an applied magnetic field can switch between orbital-ordered…

20 kHz Magnetic Field Emission of Induction Cooking Heaters

Research RF Safe Research Library Jan 1, 2004

This exposure assessment measured 20 kHz magnetic field leakage from induction cooking heaters across four models and compared results with ICNIRP general public limits. The maximum reported magnetic flux density was 16 µT at a specified measurement point using two S-type pans. Field leakage depended on pan size and…

The effect of pulsed and sinusoidal magnetic fields on the morphology of developing chick embryos

Research RF Safe Research Library Jan 1, 1997

This animal study reports results from five experimental campaigns over five years examining weak magnetic field exposure and morphological abnormalities in White Leghorn chick embryos. Four campaigns reported statistically significant increases in abnormality rates, while one pulsed-field campaign showed only a…

← Prev Page 19 / 20 Next →