Cell phone usage and erectile function.
Research
RF Safe Research Library
Jan 1, 2013
This pilot case-control study compared 20 men with erectile dysfunction to 10 healthy controls using SHIM/IIEF scores and a questionnaire on cell phone habits. Weekly call time was not significantly different between groups, but men with ED reported significantly longer daily time carrying a switched-on phone. The…
Quasi-phase-matched second harmonic generation in silicon nitride ring resonators controlled by static electric field.
Research
RF Safe Research Library
Jan 1, 2013
This paper proposes and simulates actively-controlled second harmonic generation in a silicon nitride ring resonator. Quasi-phase matching is induced by a periodic static electric field generated by voltage applied to electrodes along the ring. Simulations report a calculated efficiency of -21.67 dB at 60 mW pump…
Epidemiological characteristics of mobile phone ownership and use in korean children and adolescents.
Research
RF Safe Research Library
Jan 1, 2013
This cross-sectional analysis used three Korean databases (2008–2011; n=21,693) to describe mobile phone ownership and use among children and adolescents and how these patterns vary by socioeconomic position. Ownership and use were higher among females, older students, and in 2011 compared with 2008, and the age of…
Motion properties of the sanals of the primo vascular system under a magnetic field.
Research
RF Safe Research Library
Jan 1, 2013
This animal/lab study examined motion of ~1 μm sanals from the rabbit primo vascular system under a low static magnetic field (100 Oe). The reported average velocity of five sanals in saline was ~1.0 pixel/second in random directions relative to the field. The authors suggest the applied magnetic field weakens sanal…
Development of a prototype of the tele-localisation system in radiotherapy using personal digital assistant via wireless communication.
Research
RF Safe Research Library
Jan 1, 2013
This paper describes development and testing of a Wi-Fi–enabled tele-localisation prototype for radiotherapy field localisation using a personal digital assistant (PDA). Trial tests on 30 subjects across multiple treatment regions reported localisation times under 1.5 minutes and similar transmission speeds across…
A wireless magnetoresistive sensing system for an intraoral tongue-computer interface.
Research
RF Safe Research Library
Jan 1, 2012
This engineering paper presents an intraoral version of the Tongue Drive System (iTDS) built into a dental retainer. It uses four 3-axis magnetoresistive sensors to detect tongue motion and transmits digitized data wirelessly via a dual-band 27/432 MHz transmitter, with configuration updates via a 13.56 MHz inductive…
Prenatal and Postnatal Cell Phone Exposures and Headaches in Children.
Research
RF Safe Research Library
Jan 1, 2012
This cohort analysis from the Danish National Birth Cohort examined whether prenatal and/or postnatal cell phone exposure was associated with headaches in children at age seven. Using maternal questionnaire data for 52,680 children, the study reports higher odds of migraines and headache-related symptoms among…
[Research on WiFi-based wireless microscopy on a mobile phone and its application].
Research
RF Safe Research Library
Jan 1, 2012
This paper describes an engineering device for wireless microscopy using a mobile phone and a WiFi system. The system allows recording, displaying, and storing microscopic images from a remote end via wireless LAN. Conceptual demonstrations are reported for monitoring common objects and liver cancer cells, with…
Electromagnetic energy radiated from mobile phone alters electrocardiographic records of patients with ischemic heart disease.
Research
RF Safe Research Library
Jan 1, 2012
This study assessed whether mobile phone radiofrequency exposure during a 40-second ringing period alters ECG parameters in 356 participants across cardiac disease groups, with gender stratification. The authors report QTc prolongation in males across groups, including males with ischemic heart disease, and…
Nanocomposite dielectrics in PbO-BaO-Na2O-Nb2O5-SiO2 system with high breakdown strength for high voltage capacitor applications.
Research
RF Safe Research Library
Jan 1, 2012
This engineering materials study reports fabrication and characterization of nanocomposite dielectrics in a PbO-BaO-Na2O-Nb2O5-SiO2 glass-ceramic system. X-ray diffraction and microstructural observations describe temperature-dependent phase formation with nanometer-sized crystallites dispersed in a glass matrix. The…
Effect of extremely low frequency electromagnetic field exposure on sleep quality in high voltage substations.
Research
RF Safe Research Library
Jan 1, 2012
This case-control study measured electric field intensity and magnetic flux density in high voltage substations and estimated workers' ELF-EMF exposure over a shift. Sleep quality was assessed using the PSQI in 67 exposed workers and 110 controls. The study reports no statistically significant difference in overall…
Low-frequency electromagnetic fields do not alter responses of inflammatory genes and proteins in human monocytes and immune cell lines.
Research
RF Safe Research Library
Jan 1, 2012
This in vitro study examined whether low-frequency electromagnetic fields (a complex multiple waveform field and a 50 Hz sine wave) alter inflammatory gene and protein responses in human immune cells. Across time course experiments in THP-1 cells and primary monocytes/macrophages, the authors report no significant…
The mobile phone as a tool in improving cancer care in Nigeria.
Research
RF Safe Research Library
Jan 1, 2012
This study evaluated mobile phone use as a tool to improve cancer care follow-up and communication in a low-resource Nigerian setting. Among 1176 oncology patients, sustained follow-up at 24 months was reported as much higher in those receiving the phone intervention than in those who did not. Patients also reported…
Effects of radiofrequency radiation exposure on blood-brain barrier permeability in male and female rats
Research
RF Safe Research Library
Jan 1, 2011
This rat study tested whether acute exposure to 0.9 and 1.8 GHz continuous-wave radiofrequency radiation alters blood-brain barrier permeability. Using Evans-blue/albumin as a tracer, the authors report no BBB leakage in exposed female rats but a significant increase in albumin in exposed male rat brains versus sham.…
Effects of chain stiffness and salt concentration on responses of polyelectrolyte brushes under external electric field.
Research
RF Safe Research Library
Jan 1, 2011
This paper reports molecular dynamics simulations of polyelectrolyte brushes subjected to external electric fields, focusing on how chain stiffness and salt concentration affect responses. The simulations suggest higher salt concentrations strengthen an induced opposing field from ion redistribution, which resists…
Milk processed by pulsed electric fields: evaluation of microbial quality, physicochemical characteristics, and selected nutrients at different storage conditions.
Research
RF Safe Research Library
Jan 1, 2011
This study evaluated pulsed electric fields (PEF) as a pasteurization method for raw skim and whole milk across multiple treatment intensities and storage conditions. The abstract reports only minor changes in physicochemical properties and small decreases in some composition measures under stronger treatments.…
Effect of electromagnetic radiofrequency radiation on the rats' brain, liver and kidney cells measured by comet assay.
Research
RF Safe Research Library
Jan 1, 2011
This animal study assessed DNA damage in rat brain, liver, and kidney cells after repeated whole-body exposure to 915 MHz GSM-modulated RF radiation (SAR 0.6 W/kg) using the comet assay. Tail length was slightly increased in brain cells and differed more notably in liver and kidney samples versus sham controls, while…
Response identification in the extremely low frequency region of an electret condenser microphone.
Research
RF Safe Research Library
Jan 1, 2011
This engineering study describes an experimental setup using a small electret condenser microphone connected to a notebook/PC to detect extremely low frequency signals. Using a small air cell made from a drilled DVD plate with a speaker and microphone on opposite sides, the microphone captured signals in the 0.5–20…
Mobile phones and short message service texts to collect situational awareness data during simulated public health critical events.
Research
RF Safe Research Library
Jan 1, 2011
This university-based pilot study evaluated whether two-way SMS text messaging could be used to collect situational assessment data during simulated public health critical events. Among 63 enrolled students, 76.7% of prompted SMS surveys were completed, and most responses were returned quickly. The authors conclude…
Measurement of creatine kinase reaction rate in human brain using magnetization transfer image-selected in vivo spectroscopy (MT-ISIS) and a volume ³¹P/¹H radiofrequency coil in a clinical 3-T MRI system.
Research
RF Safe Research Library
Jan 1, 2011
This paper describes a new magnetization transfer 31P MRS approach (MT-ISIS) for measuring the creatine kinase forward reaction rate in the human brain using a volume 31P/1H RF coil on a clinical 3-T MRI system. The method aims to reduce acquisition time (30 min), avoid scalp muscle contamination, improve RF…
Impact of a pulsed electric field on damage of plant tissues: effects of cell size and tissue electrical conductivity.
Research
RF Safe Research Library
Jan 1, 2011
This experimental and modeling study examined pulsed electric field (PEF) permeabilization in several fruit and vegetable tissues at 293 K using 1000 μs pulses and field strengths of 400 and 1000 V·cm(-1). While electroporation theory predicts greater damage in tissues with larger cells, the authors report this…
Increased blood oxygen level-dependent (BOLD) sensitivity in the mouse somatosensory cortex during electrical forepaw stimulation using a cryogenic radiofrequency probe.
Research
RF Safe Research Library
Jan 1, 2011
This engineering-focused mouse fMRI study evaluated a 400-MHz cryogenic RF probe (CryoProbe) versus a conventional room-temperature surface coil during electrical forepaw stimulation. The CryoProbe increased image SNR and temporal SNR and reduced temporal noise compared with the room-temperature coil. The authors…
Reduction of implant RF heating through modification of transmit coil electric field.
Research
RF Safe Research Library
Jan 1, 2011
This engineering study describes modifying MRI RF transmit coil electric-field distributions to create electric field-free zones without substantially changing transmit sensitivity. Phantom experiments are reported to show reduced implant heating when a zero electric-field plane is aligned with the implant location.…
Impact of a static magnetic field on the electricity production of Shewanella-inoculated microbial fuel cells.
Research
RF Safe Research Library
Jan 1, 2011
This study investigated how exposure to a static magnetic field affects electricity production in Shewanella-inoculated microbial fuel cells across different reactor configurations. A 100 mT field was reported to increase maximum voltage and the effect was described as immediate and reversible, with possible adverse…
Effects of low frequency electromagnetic fields on the chondrogenic differentiation of human mesenchymal stem cells.
Research
RF Safe Research Library
Jan 1, 2011
This in vitro study examined whether extremely low-frequency magnetic fields affect chondrogenic differentiation of human mesenchymal stem cells in pellet culture. Cells exposed for 3 weeks to a homogeneous sinusoidal 5 mT magnetic field showed increased collagen type II expression (significant at passage 6) and…