Archive

399 posts

Showing results for: REM

Dynamic control of adsorption sensitivity for photo-EMF-based ammonia gas sensors using a wireless network.

Research RF Safe Research Library Jan 1, 2011

This engineering paper proposes a control method for a photo-electromagnetic field (EMF)-based ammonia gas sensor that uses a wireless network and adjusts illumination light intensity. It reports that measurement error is minimized over 3800 ppm ammonia when the concentration corresponds to an optimal illumination…

Fuzzy mobile-robot positioning in intelligent spaces using wireless sensor networks.

Research RF Safe Research Library Jan 1, 2011

This engineering study develops and experimentally evaluates a fuzzy-logic method for locating mobile robots in an intelligent space using wireless sensor networks. Localization relies on inter-node range measurements estimated from RF signal strength attenuation, which the authors describe as noisy and unreliable.…

Interoperation of an UHF RFID reader and a TCP/IP device via wired and wireless links.

Research RF Safe Research Library Jan 1, 2011

This engineering paper describes a system implementation for interoperation between a 915 MHz UHF RFID reader and a TCP/IP gateway device. The architecture uses wired communication between the TCP/IP device and RFID reader, and wireless ZigBee (IEEE 802.15.4) links to an end-device/coordinator. Web-based tests are…

Response identification in the extremely low frequency region of an electret condenser microphone.

Research RF Safe Research Library Jan 1, 2011

This engineering study describes an experimental setup using a small electret condenser microphone connected to a notebook/PC to detect extremely low frequency signals. Using a small air cell made from a drilled DVD plate with a speaker and microphone on opposite sides, the microphone captured signals in the 0.5–20…

Design and implementation of a wireless sensor network-based remote water-level monitoring system.

Research RF Safe Research Library Jan 1, 2011

This article reports an engineering implementation of a wireless sensor network-based remote water-level monitoring system. The system includes field sensors, a base station, a data center, and a web publishing module, and is described as providing real-time monitoring and anti-jamming capability. The authors state…

Effects of extremely low frequency magnetic field on oxidative balance in brain of rats.

Research RF Safe Research Library Jan 1, 2011

This animal study examined whether an extremely low frequency magnetic field (7 mT, 40 Hz) used in magnetotherapy alters oxidative balance in rat brain after 10 days of exposure. The 30 min/day exposure condition was associated with increased lipid peroxidation, while the 60 min/day condition was associated with…

Measurement of creatine kinase reaction rate in human brain using magnetization transfer image-selected in vivo spectroscopy (MT-ISIS) and a volume ³¹P/¹H radiofrequency coil in a clinical 3-T MRI system.

Research RF Safe Research Library Jan 1, 2011

This paper describes a new magnetization transfer 31P MRS approach (MT-ISIS) for measuring the creatine kinase forward reaction rate in the human brain using a volume 31P/1H RF coil on a clinical 3-T MRI system. The method aims to reduce acquisition time (30 min), avoid scalp muscle contamination, improve RF…

Increased blood oxygen level-dependent (BOLD) sensitivity in the mouse somatosensory cortex during electrical forepaw stimulation using a cryogenic radiofrequency probe.

Research RF Safe Research Library Jan 1, 2011

This engineering-focused mouse fMRI study evaluated a 400-MHz cryogenic RF probe (CryoProbe) versus a conventional room-temperature surface coil during electrical forepaw stimulation. The CryoProbe increased image SNR and temporal SNR and reduced temporal noise compared with the room-temperature coil. The authors…

Impact of a static magnetic field on the electricity production of Shewanella-inoculated microbial fuel cells.

Research RF Safe Research Library Jan 1, 2011

This study investigated how exposure to a static magnetic field affects electricity production in Shewanella-inoculated microbial fuel cells across different reactor configurations. A 100 mT field was reported to increase maximum voltage and the effect was described as immediate and reversible, with possible adverse…

Effects of low frequency electromagnetic fields on the chondrogenic differentiation of human mesenchymal stem cells.

Research RF Safe Research Library Jan 1, 2011

This in vitro study examined whether extremely low-frequency magnetic fields affect chondrogenic differentiation of human mesenchymal stem cells in pellet culture. Cells exposed for 3 weeks to a homogeneous sinusoidal 5 mT magnetic field showed increased collagen type II expression (significant at passage 6) and…

Correction of main and transmit magnetic field (B0 and B1) inhomogeneity effects in multicomponent-driven equilibrium single-pulse observation of T1 and T2.

Research RF Safe Research Library Jan 1, 2011

This methods paper addresses how B0 (main field) and B1 (transmit field) inhomogeneities can bias SPGR and bSSFP steady-state MRI signals used for multicomponent T1/T2 relaxometry and myelin water analysis. It describes using DESPOT1-HIFI to calibrate flip angles and adding a B0-related parameter with multiple…

Orientation and Dynamics of ZnO Nanorod Liquid Crystals in Electric Fields.

Research RF Safe Research Library Jan 1, 2010

This materials study reports that ZnO nanorod polymer hybrids can form liquid-crystalline phases and exhibit orientation switching under an applied AC electric field. The orientation reportedly changes from planar to homeotropic, analogous to switching in low-molecular liquid crystals. Dielectric measurements and…

Electric field gradients in (111)In-doped (Hf/Zr)3Al2 and (Hf/Zr)4Al3 mixed compounds: ab initio calculations, perturbed angular correlation measurements and site preference.

Research RF Safe Research Library Jan 1, 2010

This materials-physics study investigated quadrupolar hyperfine interactions of (111)In→(111)Cd probes in polycrystalline Zr4Al3 and Hf4Al3 containing minority (Zr/Hf)3Al2 phases. The authors observed a strong preference of (111)In solutes for the minority (Zr/Hf)3Al2 phases. Ab initio EFG calculations were used to…

Slow relaxation of magnetoresistance in AlGaAs-GaAs quantum well structures quenched in a magnetic field.

Research RF Safe Research Library Jan 1, 2010

This study reports slow relaxation of magnetoresistance in selectively doped p-GaAs-AlGaAs structures following application of a magnetic field. The authors emphasize efforts to rule out temperature fluctuation artifacts and state that the main relaxation features remain. They interpret the phenomenon using a…

Electric field induced structuring in clay-oil suspensions: new insights from WAXS, SEM, leak current, dielectric permittivity, and rheometry.

Research RF Safe Research Library Jan 1, 2010

This laboratory/engineering study examined electric-field-induced structuring in clay-oil suspensions using WAXS, SEM, rheometry, and electrical measurements. Particle orientation was quantified via an orientational order parameter derived from diffraction peak azimuthal changes, and chain versus column formation was…

Ultrasonic propagation velocity in magnetic and magnetorheological fluids due to an external magnetic field.

Research RF Safe Research Library Jan 1, 2010

This engineering-focused study measured ultrasonic propagation velocity in hydrocarbon-based magnetic and magnetorheological fluids under an external magnetic field. The authors report that clustering structures formed in the fluids influence ultrasonic propagation velocity, with observed hysteresis and anisotropy.…

Scientific Committee on Emerging and Newly Identified Health Risks

Research RF Safe Research Library Jan 1, 2009

This SCENIHR Opinion updates earlier 2009 SCENIHR documents on EMF health effects and research needs, focusing on new information and remaining knowledge gaps. The abstract primarily characterizes sources and patterns of exposure across static, ELF, IF, and RF fields in both public and occupational settings. It notes…

Localizing Broca's area for transcranial magnetic stimulation: Comparison of surface distance measurements and stereotaxic positioning.

Research RF Safe Research Library Jan 1, 2009

This methods study evaluated an MRI-based surface distance measurements (SDM) approach for localizing Broca's area for TMS coil placement without external tracking devices. Coil positioning using SDM was compared with an advanced frameless stereotaxic navigation system. The reported mean difference between methods…

Cyanide orientational ordering and copper electric field gradients in CuCN.N2H4.

Research RF Safe Research Library Jan 1, 2009

This study reports solid-state NMR (13C and 15N MAS) measurements on CuCN·N2H4 to extract copper quadrupole coupling constants and characterize cyanide ordering. Ab initio calculations were used to determine electric field gradient and chemical shielding tensor orientations needed for spectral analysis. The authors…

Dominant mobility modulation by the electric field effect at the LaAlO3/SrTiO3 interface.

Research RF Safe Research Library Jan 1, 2009

This Physical Review Letters paper reports magnetotransport measurements on a gated LaAlO3/SrTiO3 interface to assess the main effect of an applied gate electric field. The authors find that mobility changes dominate over sheet carrier density changes (mobility variation reported as nearly fivefold larger). They also…

Cutaneous remodeling and photorejuvenation using radiofrequency devices.

Research RF Safe Research Library Jan 1, 2009

This concise review discusses radiofrequency (RF) dermatologic devices used for nonablative skin rejuvenation and related indications. It characterizes RF effects on tissue as primarily thermal, aiming to heat targeted skin layers to trigger collagen changes and subsequent remodeling. The abstract cites preliminary…

Synthesis of polylactic acid-polyglycolic acid blends using microwave radiation.

Research RF Safe Research Library Jan 1, 2008

This engineering/materials study describes blending PLLA and PGA using microwave irradiation to produce PLGA-related blends with varying constituent concentrations. The authors report that FTIR, NMR, and DSC measurements indicate blending and cross-linking between the polymers. The abstract does not provide microwave…

The effect of MRET polymer compound on SAR values of RF phones.

Research RF Safe Research Library Jan 1, 2008

This article describes a hypothesis and experimental testing of an MRET polymer compound applied to RF phones. It reports increased dielectric permittivity in water-based solutions and reduced SAR values in a tissue-simulating phantom head. It also reports no significant change in air measurements of phone signals,…

Greyscale intravascular ultrasound and IVUS-radiofrequency tissue characterisation to improve understanding of the mechanisms of coronary stent thrombosis in drug-eluting stents.

Research RF Safe Research Library Jan 1, 2008

This review describes proposed mechanical causes of drug-eluting stent thrombosis and notes that many are identifiable by greyscale intravascular ultrasound (IVUS). It highlights that evidence linking specific IVUS findings to stent thrombosis remains uncertain because relatively few stent thrombosis cases have been…

In vivo quantification of contrast agent concentration using the induced magnetic field for time-resolved arterial input function measurement with MRI.

Research RF Safe Research Library Jan 1, 2008

This Medical Physics article presents a phase-based MRI method to quantify paramagnetic contrast agent concentration by inverting susceptibility-induced magnetic field shifts, aiming to improve arterial input function (AIF) measurement in DCE-MRI. After in vitro validation, the approach was applied in vivo in 14…

← Prev Page 15 / 16 Next →