Archive

372 posts

Showing results for: TEM

Development of a prototype of the tele-localisation system in radiotherapy using personal digital assistant via wireless communication.

Research RF Safe Research Library Jan 1, 2013

This paper describes development and testing of a Wi-Fi–enabled tele-localisation prototype for radiotherapy field localisation using a personal digital assistant (PDA). Trial tests on 30 subjects across multiple treatment regions reported localisation times under 1.5 minutes and similar transmission speeds across…

Long-term efficacy of radiofrequency treatment of turbinate hypertrophy: a patient based point of view.

Research RF Safe Research Library Jan 1, 2013

This observational study followed 36 patients for 2 years after temperature-controlled radiofrequency tissue volume reduction for turbinate hypertrophy. Patients reported significantly lower VAS symptom scores (nasal obstruction, headache, rhinorrhoea, anosmia) after treatment compared with baseline. Urban residence…

A wireless magnetoresistive sensing system for an intraoral tongue-computer interface.

Research RF Safe Research Library Jan 1, 2012

This engineering paper presents an intraoral version of the Tongue Drive System (iTDS) built into a dental retainer. It uses four 3-axis magnetoresistive sensors to detect tongue motion and transmits digitized data wirelessly via a dual-band 27/432 MHz transmitter, with configuration updates via a 13.56 MHz inductive…

[Recanalization of nasolacrimal duct with radio frequency: preliminary study].

Research RF Safe Research Library Jan 1, 2012

This preliminary clinical series evaluated radiofrequency-assisted recanalization of the nasolacrimal duct in adults with confirmed lower lacrimal system obstruction. The procedure used a monopolar high-frequency device at 450 kHz and 150 W under local anesthesia with sedation. At 90 days postoperatively, 81.25% of…

[Research on WiFi-based wireless microscopy on a mobile phone and its application].

Research RF Safe Research Library Jan 1, 2012

This paper describes an engineering device for wireless microscopy using a mobile phone and a WiFi system. The system allows recording, displaying, and storing microscopic images from a remote end via wireless LAN. Conceptual demonstrations are reported for monitoring common objects and liver cancer cells, with…

Nanocomposite dielectrics in PbO-BaO-Na2O-Nb2O5-SiO2 system with high breakdown strength for high voltage capacitor applications.

Research RF Safe Research Library Jan 1, 2012

This engineering materials study reports fabrication and characterization of nanocomposite dielectrics in a PbO-BaO-Na2O-Nb2O5-SiO2 glass-ceramic system. X-ray diffraction and microstructural observations describe temperature-dependent phase formation with nanometer-sized crystallites dispersed in a glass matrix. The…

[Study on atmospheric VOCs in Gongga Mountain base station].

Research RF Safe Research Library Jan 1, 2012

This study measured atmospheric VOCs at the Gongga Mountain base station using weekly samples collected in 2007 and analyzed by preconcentration plus GC-MS. It reports mean concentrations of TVOCs and NMHCs, describes VOC composition, and uses PCA-based receptor modeling to attribute sources. The authors report…

Ground-state structures and structural transitions in a monolayer of magnetic dipolar particles in the presence of an external magnetic field.

Research RF Safe Research Library Jan 1, 2012

This physics study uses analytical calculations and Monte Carlo simulations to determine ground-state structures of monodisperse ferrofluid monolayers under external magnetic fields. It reports structural transitions depending on whether the field is perpendicular or parallel to the monolayer plane, with different…

Evaluation of the packaging and encapsulation reliability in fully integrated, fully wireless 100 channel Utah Slant Electrode Array (USEA): Implications for long term functionality.

Research RF Safe Research Library Jan 1, 2012

This engineering study evaluated long-term encapsulation and packaging reliability of a fully wireless 100-channel Utah Slant Electrode Array system in vitro. The device was soaked in PBS for over 12 months while being wirelessly powered/configured at 2.765 MHz and transmitting an FSK-modulated 900 MHz RF signal. The…

A robotic assistant for trans-oral surgery: the robotic endo-laryngeal flexible (Robo-ELF) scope.

Research RF Safe Research Library Jan 1, 2012

This paper describes an engineering/clinical tool development effort: the Robotic EndoLaryngeal Flexible (Robo-ELF) Scope System for manipulating flexible endoscopes in laryngeal surgery. The system includes multiple degrees of freedom, a passive positioning arm, and a custom joystick controller enabling one-handed…

Influence of magnetic field on aqueous two-phase extraction of horse ferritin in the polyethylene glycol/hydroxyethyl starch system.

Research RF Safe Research Library Jan 1, 2012

This study reports an aqueous two-phase extraction method for equine spleen ferritin using polyethylene glycol (PEG) and hydroxyethyl starch (HES). Ferritin partitioning depended on PEG/HES concentrations and PEG molecular weight, and applying a magnetic field increased ferritin accumulation in the PEG-rich phase…

Milk processed by pulsed electric fields: evaluation of microbial quality, physicochemical characteristics, and selected nutrients at different storage conditions.

Research RF Safe Research Library Jan 1, 2011

This study evaluated pulsed electric fields (PEF) as a pasteurization method for raw skim and whole milk across multiple treatment intensities and storage conditions. The abstract reports only minor changes in physicochemical properties and small decreases in some composition measures under stronger treatments.…

Template-free synthesis and self-assembly of aligned nickel nanochains under magnetic fields.

Research RF Safe Research Library Jan 1, 2011

This engineering/materials study describes a template-free solution-phase method to synthesize well-aligned nickel nanochains under applied magnetic fields. The authors report that nanochain size and morphology can be tuned by reaction temperature and magnetic field conditions, and explain alignment via magnetic…

Nanocrystalline graphite films nucleation by the radio frequency bias pretreatment.

Research RF Safe Research Library Jan 1, 2011

This paper describes an engineering method for nucleating nanocrystalline carbon films on monocrystalline silicon using a combination of microwave and radio frequency plasma-assisted chemical vapor deposition. The approach is demonstrated via deposition of nanocrystalline diamond after a seeding step and growth of…

Effect of electromagnetic radiofrequency radiation on the rats' brain, liver and kidney cells measured by comet assay.

Research RF Safe Research Library Jan 1, 2011

This animal study assessed DNA damage in rat brain, liver, and kidney cells after repeated whole-body exposure to 915 MHz GSM-modulated RF radiation (SAR 0.6 W/kg) using the comet assay. Tail length was slightly increased in brain cells and differed more notably in liver and kidney samples versus sham controls, while…

[Realization of mobile phone based wireless blood pressure monitoring system and its preliminary implementation].

Research RF Safe Research Library Jan 1, 2011

This paper describes the design and preliminary implementation of a mobile-phone-based wireless blood pressure monitoring system that transmits data via Bluetooth and computes blood pressure and heart rate on the phone. The authors state that experiments demonstrated the device’s reliability and stability, and that…

Dynamic control of adsorption sensitivity for photo-EMF-based ammonia gas sensors using a wireless network.

Research RF Safe Research Library Jan 1, 2011

This engineering paper proposes a control method for a photo-electromagnetic field (EMF)-based ammonia gas sensor that uses a wireless network and adjusts illumination light intensity. It reports that measurement error is minimized over 3800 ppm ammonia when the concentration corresponds to an optimal illumination…

Interoperation of an UHF RFID reader and a TCP/IP device via wired and wireless links.

Research RF Safe Research Library Jan 1, 2011

This engineering paper describes a system implementation for interoperation between a 915 MHz UHF RFID reader and a TCP/IP gateway device. The architecture uses wired communication between the TCP/IP device and RFID reader, and wireless ZigBee (IEEE 802.15.4) links to an end-device/coordinator. Web-based tests are…

Historical building monitoring using an energy-efficient scalable wireless sensor network architecture.

Research RF Safe Research Library Jan 1, 2011

This engineering paper describes low-power wireless sensor nodes and a cluster-based dynamic-tree hierarchical WSN architecture for monitoring historical buildings and wooden artifacts for early pest detection. The authors report simulation and demonstration results indicating improved scalability and reliability…

Effect of magnetic fields on tumor growth and viability.

Research RF Safe Research Library Jan 1, 2011

This animal study evaluated whether magnetic field exposure affects breast tumor growth and viability in mice injected with breast cancer cells. Tumor growth was monitored in real time using luciferase labeling and an in vivo imaging system. The authors report that 360 minutes of daily magnetic field exposure for up…

Design and implementation of a wireless sensor network-based remote water-level monitoring system.

Research RF Safe Research Library Jan 1, 2011

This article reports an engineering implementation of a wireless sensor network-based remote water-level monitoring system. The system includes field sensors, a base station, a data center, and a web publishing module, and is described as providing real-time monitoring and anti-jamming capability. The authors state…

Measurement of creatine kinase reaction rate in human brain using magnetization transfer image-selected in vivo spectroscopy (MT-ISIS) and a volume ³¹P/¹H radiofrequency coil in a clinical 3-T MRI system.

Research RF Safe Research Library Jan 1, 2011

This paper describes a new magnetization transfer 31P MRS approach (MT-ISIS) for measuring the creatine kinase forward reaction rate in the human brain using a volume 31P/1H RF coil on a clinical 3-T MRI system. The method aims to reduce acquisition time (30 min), avoid scalp muscle contamination, improve RF…

Increased blood oxygen level-dependent (BOLD) sensitivity in the mouse somatosensory cortex during electrical forepaw stimulation using a cryogenic radiofrequency probe.

Research RF Safe Research Library Jan 1, 2011

This engineering-focused mouse fMRI study evaluated a 400-MHz cryogenic RF probe (CryoProbe) versus a conventional room-temperature surface coil during electrical forepaw stimulation. The CryoProbe increased image SNR and temporal SNR and reduced temporal noise compared with the room-temperature coil. The authors…

Effects of low frequency electromagnetic fields on the chondrogenic differentiation of human mesenchymal stem cells.

Research RF Safe Research Library Jan 1, 2011

This in vitro study examined whether extremely low-frequency magnetic fields affect chondrogenic differentiation of human mesenchymal stem cells in pellet culture. Cells exposed for 3 weeks to a homogeneous sinusoidal 5 mT magnetic field showed increased collagen type II expression (significant at passage 6) and…

A rapid and facile synthesis of nanofibrillar polyaniline using microwave radiation.

Research RF Safe Research Library Jan 1, 2010

This engineering study describes a microwave-assisted method to synthesize polyaniline (PANI) nanofibers. Reported yields under microwave irradiation were similar to conventional synthesis but achieved in minutes rather than hours. Structural and morphological characterization (FTIR, Raman, SEM, TEM) reportedly…

← Prev Page 13 / 15 Next →