Archive

325 posts

Showing results for: APP

Design of an ultra low power third order continuous time current mode ΣΔ modulator for WLAN applications.

Research RF Safe Research Library Jan 1, 2014

This engineering paper describes a third-order continuous-time current-mode ΣΔ modulator designed for WLAN 802.11b applications. It proposes a modified current mirror integrator and a dynamic latch-based current comparator aimed at improving bandwidth, linearity, and sampling rate. The authors report >60 dB dynamic…

Real Time Processing and Transferring ECG Signal by a Mobile Phone.

Research RF Safe Research Library Jan 1, 2014

This paper presents an engineering approach for real-time ECG signal processing on a mobile phone with remote transmission to a medical center. The method uses an IIR low-pass filter and Hilbert transform to support R-peak detection and arrhythmia alerting. Reported algorithm performance includes 96.97% sensitivity…

Molecular dynamics study of response of liquid N,N-dimethylformamide to externally applied electric field using a polarizable force field.

Research RF Safe Research Library Jan 1, 2014

This molecular dynamics simulation study examined liquid N,N-dimethylformamide exposed to uniform external electric fields from 0.001 to 1 V/nm using an extended AMOEBA polarizable force field. The authors report that fields above 0.01 V/nm significantly altered the liquid’s structure and a range of molecular and…

Ultrafast volumetric B1 (+) mapping for improved radiofrequency shimming in 3 tesla body MRI.

Research RF Safe Research Library Jan 1, 2014

This engineering/clinical MRI methods study evaluated ultrafast volumetric DREAM B1+ mapping to refine patient-adaptive RF shimming at 3T. In 20 patients and three volunteers, a multi-slice adaptive RF shimming approach reduced flip-angle deviations and improved B1+ homogeneity compared with central-slice-based…

Liver lesion conspicuity during real-time MR-guided radiofrequency applicator placement using spoiled gradient echo and balanced steady-state free precession imaging.

Research RF Safe Research Library Jan 1, 2014

This retrospective study evaluated liver lesion conspicuity during real-time MR-guided radiofrequency applicator placement using spoiled GRE and balanced SSFP MRI sequences in a 1.5 T scanner. Lesion detectability categories and contrast-to-noise ratio (CNR) were compared for hepatocellular carcinoma and liver…

Passive tracking of linac clinical flow using radiofrequency identification technology.

Research RF Safe Research Library Jan 1, 2014

This study reports implementation of a passive RFID system to passively track patient flow in a radiation therapy clinic using readers/antennae in linac vault areas. Across 4302 treatment fractions from 144 patients, the system achieved about 70% read reliability and enabled comparison of median in-vault treatment…

Mitigation of biofouling using electromagnetic fields in tubular heat exchangers-condensers cooled by seawater.

Research RF Safe Research Library Jan 1, 2014

This paper describes an engineering application of electromagnetic field (EMF) treatment to mitigate biofouling in seawater-cooled tubular heat exchanger-condensers. After allowing a biofilm to stabilize, EMF treatment was applied and was reported to precipitate dissolved ions and contribute to partial…

Assessment of extremely low frequency magnetic field exposure from GSM mobile phones.

Research RF Safe Research Library Jan 1, 2014

This paper reports extremely low frequency (ELF) magnetic flux density measurements from 47 GSM mobile phones, collected to support exposure classification in the MOBI-KIDS epidemiological study. At 25 mm, maximum resultant magnetic flux density at 217 Hz had a geometric mean of 221 nT, and inclusion of harmonics…

Reactive oxygen species elevation and recovery in Drosophila bodies and ovaries following short-term and long-term exposure to DECT base EMF.

Research RF Safe Research Library Jan 1, 2014

This animal study measured ROS in Drosophila bodies and ovaries after short- and long-term exposure to DECT base RF (1.88–1.90 GHz; SAR 0.009 W/kg). The abstract reports increased ROS in bodies after 6 h exposure and in ovaries after 0.5–1 h exposure, with apparent saturation under longer continuous exposure. It also…

Mobile phone support for rural health workers in Nepal through 'celemedicine'.

Research RF Safe Research Library Jan 1, 2013

This article describes a pilot mobile-phone-based support system (“celemedicine”) for mid-level rural health workers in Gulmi District, Nepal, enabling free calls to three general practitioner doctors at the district hospital. The intervention aims to improve appropriate referral and connectivity between peripheral…

Study on effective improvement of mobile phone sound quality in a noise environment for the hearing-impaired.

Research RF Safe Research Library Jan 1, 2013

This study evaluated whether the NAL-NL1 hearing-aid fitting formula is appropriate for hearing-impaired mobile communication, comparing it with a modified fitting formula. Speech materials were low-pass filtered at 8 kHz and presented through a mobile phone for word-recognition testing in quiet and noisy conditions.…

Patient satisfaction and efficacy of accent radiofrequency for facial skin wrinkle reduction.

Research RF Safe Research Library Jan 1, 2013

This study evaluated a cosmetic radiofrequency device (Accent) for facial wrinkle reduction in 45 women receiving four weekly sessions. Patient satisfaction was higher at 6 months than at 1 month after treatment, and the authors suggest the approach may be effective for facial rejuvenation. The abstract emphasizes…

Quasi-phase-matched second harmonic generation in silicon nitride ring resonators controlled by static electric field.

Research RF Safe Research Library Jan 1, 2013

This paper proposes and simulates actively-controlled second harmonic generation in a silicon nitride ring resonator. Quasi-phase matching is induced by a periodic static electric field generated by voltage applied to electrodes along the ring. Simulations report a calculated efficiency of -21.67 dB at 60 mW pump…

Enhancement of LIBS emission using antenna-coupled microwave.

Research RF Safe Research Library Jan 1, 2013

This engineering study describes using antenna-coupled microwave radiation to enhance laser-induced breakdown spectroscopy (LIBS) emission from a Gd2O3 sample at reduced pressure. The authors report substantially increased plasma emission intensity, higher-temperature plasma, and longer emission lifetime when…

Linear and stable photonic radio frequency phase shifter based on a dual-parallel Mach-Zehnder modulator using a two-drive scheme.

Research RF Safe Research Library Jan 1, 2013

This paper presents a theoretical and experimental demonstration of a photonic RF phase shifter based on a dual-parallel Mach-Zehnder modulator using a two-drive scheme. The approach aims to mitigate residual optical carrier effects and avoid a lowest-frequency limitation from an optical filter by driving the…

Epidemiological characteristics of mobile phone ownership and use in korean children and adolescents.

Research RF Safe Research Library Jan 1, 2013

This cross-sectional analysis used three Korean databases (2008–2011; n=21,693) to describe mobile phone ownership and use among children and adolescents and how these patterns vary by socioeconomic position. Ownership and use were higher among females, older students, and in 2011 compared with 2008, and the age of…

Tuning Mie scattering resonances in soft materials with magnetic fields.

Research RF Safe Research Library Jan 1, 2013

This paper proposes a reversible approach to tune Mie scattering resonances in random media using external low induction magnetic fields. The experimental demonstration uses ultrasound in emulsions of fluorinated ferrofluid droplets dispersed in a Bingham fluid. Magnetic-field-induced droplet deformation is reported…

Convection patterns in a liquid metal under an imposed horizontal magnetic field.

Research RF Safe Research Library Jan 1, 2013

This laboratory study examined Rayleigh-Bénard convection in liquid gallium under varying strengths of a uniform imposed horizontal magnetic field. Using ultrasonic velocity profiling and temperature monitoring, the authors mapped a regime diagram across Ra and Q and identified five flow regimes. The results describe…

Polymer-disordered liquid crystals: susceptibility to an electric field.

Research RF Safe Research Library Jan 1, 2013

This study models nematic liquid crystals embedded in random polymer networks, where disorder disrupts long-range order and produces a glassy state. It uses simulations and an Imry-Ma-like analytic approach to visualize domains, predict domain size, and calculate the response to an applied electric field. The authors…

Motion properties of the sanals of the primo vascular system under a magnetic field.

Research RF Safe Research Library Jan 1, 2013

This animal/lab study examined motion of ~1 μm sanals from the rabbit primo vascular system under a low static magnetic field (100 Oe). The reported average velocity of five sanals in saline was ~1.0 pixel/second in random directions relative to the field. The authors suggest the applied magnetic field weakens sanal…

Pulsed radiofrequency in peripheral posttraumatic neuropathic pain: A double blind sham controlled randomized clinical trial.

Research RF Safe Research Library Jan 1, 2012

This double-blind, randomized, sham-controlled trial evaluated pulsed radiofrequency applied to injured peripheral nerves for peripheral posttraumatic neuropathic pain. Among 43 analyzed participants, PRF did not show statistically significant benefit over sham for pain reduction at 3 months, nor for neuropathic pain…

Induction of thrombosis of the abdominal aneurysm sac through the application of radiofrequency. An experimental study.

Research RF Safe Research Library Jan 1, 2012

This experimental animal study evaluated whether a radiofrequency method could induce thrombosis within an abdominal aortic aneurysm sac to potentially prevent endoleaks after endovascular repair. Six dogs received radiofrequency blood clotting of the sac and then stent-grafting, compared with a historical group of…

Citrate-capped gold nanoparticle electrophoretic heat production in response to a time-varying radiofrequency electric-field.

Research RF Safe Research Library Jan 1, 2012

This in vitro study examines RF-induced heat production in citrate-capped gold nanoparticle suspensions while minimizing confounding Joule heating from ionic buffers. It reports size-dependent heating detectable only for ≤10 nm particles, with heating scaling with concentration and surface area and being attenuated…

Use of a hip arthroscopy flexible radiofrequency device for capsular release in frozen shoulder.

Research RF Safe Research Library Jan 1, 2012

This article describes a surgical technique for arthroscopic capsular release in adhesive capsulitis using a flexible hip arthroscopy radiofrequency ablator. The authors present it as a creative approach intended to improve safety and precision in a procedure that can be technically challenging. The abstract does not…

Removal of earth's magnetic field effect on magnetoelastic resonance sensors by an antisymmetric bias field.

Research RF Safe Research Library Jan 1, 2012

This engineering study addresses measurement error in magnetoelastic resonance sensors caused by Earth's magnetic field. The authors present an antisymmetric magnetic bias field approach and compare the ribbon response to external perturbation fields against a conventional design. They report a 77% reduction in the…

← Prev Page 10 / 13 Next →